SAAT Corporation
Your Home Environment Monitoring System       1 
Contents 
What is it?…………………………………………………………………………….. 2 
 
In the box …………………………………………………………………………….. 2 
 
Features …………………………………………………………………………….. 2 
 
Top Level Design ……………………………………………………………………. 3 
 
Modular Software ……………………………………………………………………. 4 
 
Local Operation Mode FSM …………………………………………………… 5 
 
Remote Operation Mode FSM …………………………………………………… 8 
 
Keypad …………………………………………………………………………….. 11 
 
EAR DOG Module LCD ……………………………………………………………. 13 
 
Honeywell HumidIcon Temperature and Humidity Sensor …………………. 14 
 
Pressure Sensor …………………………………………………………………….. 16 
 
MAX1270 Analog­to­Digital Converter …………………………………………… 17 
 
XBee Wireless Module ……………………………………………………………. 19 
 
Troubleshooting ……………………………………………………………………..  21 
 
Contact Information ……………………………………………………………. 21 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       2 
Welcome to your SAAT system 
 
What is it?
This system is an Environmental Monitoring and Control System (EMCS) that can 
monitor the temperature, humidity and pressure of the room as well as adjust the temperature 
and humidity to a set level. Our system has two different operation modes: local mode and 
remote mode. In local mode, the measurands can be displayed on an LCD screen built into the 
system and the setpoints for temperature and humidity can be modified using the keypad. In 
remote mode, the same operations can be executed over the internet remotely from any internet 
capable device. This is the biggest advantage of the system.  
 
In the box
● Environmental Monitoring and Control System (EMCS) unit 
● Power adapter (9V output) 
● Control signals connector for AC, Furnace, Humidifier and Dehumidifier 
 
Features
● Read the temperature 
● Read the humidity 
● Read the pressure 
● Set the temperature to control the AC or Furnace 
● Set the humidity to control the humidifier or dehumidifier 
● In­built wifi unit to perform all operations remotely from any internet connected device 
● Optional 9V battery connector for ease of use 
 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       3 
Top Level Design
The following are the components of the system: 
­ EA DOGM163A LCD controller and driver 
­ Honeywell HumidIcon Digital Temperature and Humidity Sensor 
­ MPXHZ6130A Pressure Sensor 
­ MAX1270 Analog­to­Digital Converter with SPI 
­ 4x4 Keypad (Some keys are not used for the final design) 
­ XBee Wireless Module 
­ Control signals for AC, Furnace, Humidifier and Dehumidifier 
 
Figure 1: Top level system block diagram 
The system uses SPI to communicate with the sensors and the LCD display. RS232 
communication protocol is used to send and receive data via the wireless module. The AVR240 
design is used for the keypad interface to minimize hardware requirements. The system uses 
two separate finite state machines for local operation mode and remote operation mode. Both 
the state machines are described in detail below. The schematic of the ATmega128 is attached 
in the Appendix. 
SAAT Corporation
Your Home Environment Monitoring System       4 
Modular Software
 
Figure 2: Modular Program Interaction 
The functionality of the EMCS built upon several modules of code that divide and group the tasks 
carried out by the system into manageable building blocks. The figure above depicts the primary 
functions the EMCS undertakes: 
● Background Tasks ­ involve measuring the current temperature, humidity, and 
pressure, and displaying them to the LCD. The measured values are also 
compared against the set point values set by the user to determine if system 
needs to turn on or off the AC, furnace, humidifier, and/or dehumidifier. 
● Finite State Machines ­ EMCS switches between two FSM depending on which 
mode the EMCS is currently operation in. Each mode is designed to expose the 
user to  different I/O capabilities of the EMCS. Thus improving the versatility of 
system 
● Interrupt Driven ­ the interrupt service routines allow for the handling of I/O from 
the user through their use of the keypad, or a terminal when the EMCS is wireless 
mode.  
The remote_op_emcs.c located in the appendix us driver program for the EMCS. The 
program interacts with the modules max1720.c and baro_pressure.c to communicate with the 
MAX1270 to retrieve the barometric pressure. The program interacts with humidicon_task2 and 
temp_humid_humidicon to communicate with the Humidicon to retrieve both temperature and 
relative humidity. The program is able to display characters on the LCD due to the interaction to 
lcd_etc. and log_dog_iar_driver.asm The USART2.c contains the ISR (interrupt service routine) 
which stores received characters in the receive buffer, and transmits characters in the transmit 
buffer out.  
SAAT Corporation
Your Home Environment Monitoring System       5 
Local Operation Mode FSM
This Finite State Machine implements the operations of the EMCS in Local operation 
mode. The keypad is used for user input and the LCD display is used for output. This system 
allows the user to change the setpoints for the temperature (ST) and the humidity (SH). The 
setpoints can be modified one of two ways; by pressing the up or down keys on the keypad, or 
by directly inputting the tens, units and decimal digits on the keypad, in that order. Following is a 
description of the states and functions of the local finite state machine. 
 
Local FSM States: 
● Select_temp ­ This is the default state of this finite state machine. In this state, the 
cursor (#) is displayed next to the temperature setpoint on the display. This indicates that, 
the setpoint for the temperature can be modified by pressing the 2nd key on the keypad.  
● Select_hum ­ Displays the cursor (#) next to the humidity setpoint. This allows the user 
to modify the setpoint for humidity by pressing the 2nd key on the keypad. 
● Set_temp ­ This state allows to modify the setpoint for temperature. There are two ways 
of doing this. By using the up or down keys on the keypad, or by directly inputting the 
digits for the setpoint. This state advances based on the first input from the user. Using 
the up or down key modifies the measurand in 0.1 increments 
● Set_hum ­ This state allows to modify the setpoint for temperature. There are two ways 
of doing this. By using the up or down keys on the keypad, or by directly inputting the 
digits for the setpoint. This state advances based on the first input from the user. Using 
the up or down key modifies the measurand in 0.1 increments 
● Tens_T ­ Upon entering the first digit in set_temp state, tens_T waits for the next digit to 
be put in the units place. 
● Units_T ­ This state waits for decimal digit to be input on the keypad. 
● Dec_T ­ This state waits for the Enter key to be pressed and then updates the 
temperature setpoint of the EMCS and updates the display accordingly. 
● Tens_H ­ Upon entering the first digit in set_hum state, tens_H waits for the next digit to 
be put in the units place. 
● Units_H ­ This state waits for decimal digit to be input on the keypad. 
● Dec_H ­ This state waits for the Enter key to be pressed and then updates the humidity 
setpoint of the EMCS and updates the display accordingly. 
 
Local FSM Functions: 
● move_cursor_hum ­ Set the variable boolean hashtag equal to 0. The main function 
then used this variable to display the cursor next to the humidity setpoint. 
● move_cursor_temp ­ Set the variable boolean hashtag equal to 1. The main function 
then used this variable to display the cursor next to the temperature setpoint. 
● increment_ST ­ Incremented the value of the temperature setpoint by 0.1 degrees. 
● decrement_ST ­ Decremented the value of the temperature setpoint by 0.1 degrees. 
● update_ST ­ Set the flag, entered, equal to 1, enabling the main program to update the 
temperature setpoint displayed on the LCD display. 
SAAT Corporation
Your Home Environment Monitoring System       6 
● increment_SH ­ Incremented the value of the humidity setpoint by 0.1%. 
● decrement_SH ­ Decremented the value of the humidity setpoint by 0.1%. 
● update_SH ­ Set the flag, entered, equal to 1, enabling the main program to update the 
humidity setpoint displayed on the LCD display. 
● process_digit ­ Depending on the current state of the state machine, this function used 
the keycode value obtained from the keypad to change the respective digit of the 
temperature or humidity setpoints. It then updated the value of the global variables for the 
two setpoints. 
● do_nothing ­ This function does nothing in the state machine and simply prints “Do 
Nothing”. This function is used for testing and debugging the state machine. 
 
   
SAAT Corporation
Your Home Environment Monitoring System       7 
 
 
 
Figure 3: Local Operation Mode FSM state diagram 
 
 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       8 
Remote Operation Mode FSM
This Finite State Machine implements the operations of the EMCS in Local operation 
mode. The commands are transmitted and data is received through an XBee module using 
RS232 protocol. The following is the command set for the EMCS in remote operation mode: 
 
To set temperature: ST=dd.d 
To set humidity: SH=dd.d 
To read temperature: T 
Response is: T=dd.d 
To read humidity: H 
Response is: H=dd.d 
To read pressure: P 
Response is: P=dd.dd 
where d is a digit 0­9. 
 
Commands sent by the device cloud are wrapped by a Return Carriage char ‘/r’. Following is the 
description of the remote FSM: 
 
Remote FSM States: 
● display ­ Initial state of the system that waits for an incoming command to be executed. 
The input command is saved in a buffer to be able to be accessed later in the system. 
● send_temp ­ When the carriage return char ‘/r’ is received, this state returns the 
temperature and goes back to the initial state display. 
● send_pressure ­ When the carriage return char ‘/r’ is received, this state returns the 
pressure and goes back to the initial state display. 
● send_humidity ­ When the carriage return char ‘/r’ is received, this state returns the 
humidity and goes back to the initial state display. 
● process_second ­ If the first character received was an ‘S’, the following command 
must be modifying one of the setpoints. This state waits for the second character to 
determine if temperature setpoint or the humidity setpoint is to be modified. 
● wait_H ­ This state waits for an ‘=’ character. 
● tens_H ­ This state indicates that the next character received is the tens digit of the 
humidity setpoint. The present state variable is used by the process_digit function to 
determine what position the digit is in. 
● ones_H ­ This state indicates that the next character received is the units digit of the 
humidity setpoint. 
● dot_H ­ Waits for a decimal point to be entered after the units digit. 
● stay_H ­ Waits for a valid digit to be entered for the decimal digit of humidity setpoint. 
● decimal_H ­ Waits for a carriage return character to update the humidity setpoint and 
return to the initial state of the system. 
● wait_T ­ This state waits for an ‘=’ character. 
SAAT Corporation
Your Home Environment Monitoring System       9 
● tens_T ­ This state indicates that the next character received is the tens digit of the 
temperature setpoint. 
● ones_T ­ This state indicates that the next character received is the units digit of the 
temperature setpoint. 
● dot_T ­ Waits for a decimal point to be entered after the units digit. 
● stay_T ­ Waits for a valid digit to be entered for the decimal digit of temperature setpoint. 
● decimal_T ­ Waits for a carriage return character to update the temperature setpoint and 
return to the initial state of the system. 
 
 
Remote FSM Functions: 
● save_command ­ Saves the incoming character in a buffer to be accessed later. 
● return_temp ­ Sends the temperature measurement out to the remote station in the 
format: T=dd.d. 
● return_pressure ­ Sends the pressure measurement out to the remote station in the 
format: P=dd.dd. 
● return_hum ­ Sends the humidity measurement out to the remote station in the format: 
H=dd.d. 
● process_digitR ­ Depending on the present state of the machine, this function used the 
digit to update the respective digits of one of the setpoint values.  
● send_SH ­ The new humidity setpoint is updated and displayed on the LCD screen on 
the device. 
● send_ST ­ The new temperature setpoint is updated and displayed on the LCD screen 
on the device. 
SAAT Corporation
Your Home Environment Monitoring System       10 
 
Figure 4: Remote Operation Mode FSM state diagram 
 
 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       11 
Keypad
A 4x4 keypad is used to get input from the user in local operation mode. The keypad is used to 
modify the setpoints for the temperature and humidity measurands. The AVR240 design is used 
to achieve keypad scanning using minimal hardware. 
 
 
 
Figure 5: Keypad Scanning Design 
Courtesy: AVR240 application notes 
In this design, the rows are connected to the lower nibble of Port C and the columns are 
connected to the higher nibble of Port C. Initially the pins of the higher nibble are set up as 
outputs writing a logic ‘0’. Pins of the lower nibble are set up as inputs with internal pull up 
resistors enabled. INT0 is enabled to trigger on a falling edge. When a key is pressed, the row 
and column of that key are connected together. This pulls down the logic on that pin to a logic ‘0’ 
calling the interrupt service routine. The service routine then scans through the lower nibble of 
Port C to determine the row of the pressed key. Then, the direction of the pins of Port C are 
swapped. The higher nibble of Port C is scanned to determine the column of the key pressed. 
The combination of this row and column number is assigned a specific key value. This key value 
is then used to look up a table for the keycode of the key that was pressed.  
SAAT Corporation
Your Home Environment Monitoring System       12 
 
Figure 6: Keypad Scanning ISR Flowchart 
Courtesy: AVR240 application notes 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       13 
EAR DOG Module LCD
The EAR DOG Module DOGM163W­A used in this system is a SPI LCD display 
controller and driver with a 3 line 16 character dot matrix LCD panel. The controller has two 8­bit 
registers, the instruction register (IR) and the data register (DR). The controller has parallel 
interface but it is also SPI compatible. In this system SPI is used to write to the display. The 
Register Select input (RS) selects the IR when RS = 0 and the DR when RS = 1. The IR stores 
instruction codes and address information for the DDRAM and Character Generator RAM 
(CGRAM). The DR holds the data to be written to the DDRAM or CGRAM. The address counter 
register (AC) holds the address of the locations in DDRAM or CGRAM.  
 
Figure 7: LCD DOG Module connections 
Courtesy: Professor Kenneth Short’s lecture slides 
The MOSI and SCK signals of the DOG module are shared by other SPI peripherals in the 
system. The RS signal is connected to the PB4 of the ATmega128. The LCD chip select signal 
(/SS) is connected to PB0. These connections are made using a JTAG connector shown below. 
 
Figure 8: LCD JTAG Connector 
 
SAAT Corporation
Your Home Environment Monitoring System       14 
Honeywell HumidIcon Temperature and Humidity Sensor
This design uses a Honeywell HIH9000 series SOIC­8 SMD with serial output. This 
sensor is a combined temperature and humidity sensor with 14­bit resolution. In a measurement 
cycle, the sensor is normally in power down mode. To wake the sensor and make a 
measurement, a Measurement Request (MR) command is used. A MR command is an 8­bit 
read and then incoming data is ignored. A Data Fetch (DF) command is then used to read the 
temperature and/or humidity. 
 
Figure 9: HumidIcon Measurement Cycle 
Courtesy: Professor Kenneth Short’s Lecture Slides 
The sensor is a Read only device and uses the shared MISO input from the 
microcontroller. Pin PortA 0 is used as a select signal for the sensor. A data fetch packet 
returned from the humidicon has the following format: [ {S(1:0),C(13:8)}, {C(7:0)}, {T(13:6)}, 
{T(5:0),xx} ] where, 
S(1:0) = Status bit of the packet (00 ­ normal operation, valid data; 01 ­ stale data, no new data) 
C(13:8) = Upper six bits of the 14­bit humidity  
C(7:0) = Lower eight bits of the 14­bit humidity 
T(13:6) = Upper eight bits of the 14­bit temperature 
T(5:0) = Lower 6 bits of the 14­bit temperature 
xx = don’t care. 
 
Figure 10: Humidicon Data packet 
Courtesy: Professor Kenneth Short’s Lecture Slides 
Hence, a complete measurement of both temperature and humidity takes a total of four SPI 
transfer cycles. This raw data is then scaled and converted to the required units to be displayed.  
SAAT Corporation
Your Home Environment Monitoring System       15 
 
Figure 11: HumidIcon Schematic 
 
Conversion and Scaling of Raw Data 
1. The four data packets are stored in 4 separate unsigned integers. Using the above 
notation, C(13:8), C(7:0), T(13:6), T(5:0) are to be stored in separate variables C1, C2, 
T1, T2, respectively. 
2. Mask the C1 with 0x3F to eliminate the two unnecessary MSB of C1 that do not contain 
the value of the raw humidity. 
3. Mask T2 with 0xFC to eliminate the two unnecessary LSB of T2 that do not contain the 
value of the raw temperature. 
4. Shift C1 to right 8 positions to place the high nibble of the raw humidity into the MSBs. 
5. Shift T1 to the right 8 positions to place the high bible of the raw temperature into the 
MSBS. 
6. Performing a bitwise OR of C1 and C2 will yield the complete raw value of Humidity. 
7. Performing a bitwise OR of T1 and T2 will yield the complete raw value of temperature, 
after the OR result is shifted to the left two position. 
 
         (1)caled Temperature  000S =   2 −214
Raw Temperture   100 165* *
− 4  
                                   (2)caled Humidity    S = 2 −214
Raw Hiumidity 100 100* *
 
 
See files humidion _task2.c and temp_humid_humdicon.c in the appendix to see process 
executed in C. 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       16 
Pressure Sensor
The transducer used in this system is a Freescale MPXHZ6130A Pressure sensor. This 
sensor has a 1.5% accuracy over 0 degrees to 85 degrees Celsius. It comes in a surface mount 
package and is suitable for microcontroller based systems. The basic characteristics of the 
sensor are shown in the table below from the datasheet: 
Figure 12: MPXHZ6130A Pressure Sensor Characteristics 
Courtesy: MPXHZ6130A Datasheet 
The analog output of this sensor is connected an Analog­to­Digital converter. 
 
Figure 13: MPXHZ6130A Schematic 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       17 
MAX1270 Analog-to-Digital Converter
The MAX1270 is a Data­Acquisition­System (DAS) IC that has a multiplexer, to switch 
between input channels, signal conditioning circuit for gain and offset adjustment, and an 
Analog­to­Digital converter with Voltage reference. It allows up to eight analog input channels. It 
has a 12­bit resolution with 0.5 LSB linearity Our system uses a SPI enabled version to save port 
pins on the microcontroller. This is used to convert the analog pressure sensor output to a digital 
output to be monitored and used by the microcontroller. Channel 0 analog input is used in our 
system.  
To initiate a conversion, a Control Byte needs to be transmitted. The control byte selects 
the input channel for a particular conversion, selects the full scale input voltage range, unipolar or 
bipolar modes, and the clock and power down mode. The control byte has the following format: 
CB = {Start, SEL2, SEL1, SEL0, RNG, BIP, PD1, PD0} 
Bit 7 ­ Start: First logic 1 after the /CS goes low defines the beginning of a control byte. 
Bit 6:4 ­ Select bits: The three bits select the desired analog input channel. 
Bit 3 ­ Range: Selects the full scale voltage range for the conversion. (Table __) 
Bit 2 ­ Bip: Unipolar or Bipolar operation mode (Table __) 
Bit 1:0 ­ Power Down mode: 00 for normal operation (always on) with internal clock. 
 
 
Table 1: Range and Polarity selection for MAX1270 
Courtesy: MAX1270 Datasheet 
 
The timing waveform below from the MAX1270 datasheet shows the detailed timing 
requirements. After the Chip Select input (/CS) signal goes low, the control byte for a conversion 
is transmitted. After the transfer of the control byte, the chip is to be unselected (/CS=1). This 
sets the Strobe signal (SSTRB) to a logic 0 indicating the start of a conversion. The end of 
conversion is indicated by the SSTRB signal going high. Once the SSTRB signal goes high, our 
design transfers two dummy bytes over the MOSI line to read the 12­bit ADC output over the 
MISO line. For faster continuous conversion cycles, a second control byte can be transferred 
after the first dummy byte to initiate another conversion. However, our system does a total of 
three byte transfers, one control byte and two dummy bytes. At the end of the second dummy 
byte, the chip is deselected. INT1 of the microcontroller is used to trigger an interrupt service 
routine when end of conversion signal occurs on the SSTRB. 
SAAT Corporation
Your Home Environment Monitoring System       18 
 
Figure 14: MAX1270 ADC Timing waveform 
Courtesy: MAX1270 Datasheet 
 
Figure 15: MAX1270 ADC Schematic 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       19 
XBee Wireless Module
The XBee 802.15.4 wireless transmitter/receiver converts RS232 protocol signals into a 
wireless RS232 protocol data stream. In remote operation mode of the EMCS, the XBee is used 
to receive commands from a remote station and send data back. This enables the setting of 
temperature and humidity setpoints from any internet capable device. The ATmega128 uses 
USART0 to communicate with the XBee module. The base station sends out a command 
through the USART, which then goes to the XBee for wireless transmission. A remote station is 
also able to send commands back to the base station through a device cloud that is integrated 
with the XBee. The Heroku cloud application platform provides for customized device cloud 
capabilities. The XBee module comes with its own device cloud. Logging into the Heroku device 
cloud for XBee gives us loads of capabilities via widgets to communicate with the XBee. Our 
system uses a simple text interface that is able to send and receive data from the XBee module 
over the internet.  
 
The Xbee needs a 3.3V power supply. Since this system is primarily 5V, a voltage 
regulator is used to convert 5V down to 3.3V. Because the XBee is operating at 3.3V, it cannot 
be directly connected to the ATmega128. The voltage and current characteristics of both the 
devices need to be compatible. The XBee RxD input from the microcontroller is connected to a 
voltage divider to limit the voltage.  
 
Figure 16: XBee ­ ATmega128 Compatibility Requirements 
Courtesy: Professor Kenneth Short’s Lecture Slides 
 
SAAT Corporation
Your Home Environment Monitoring System       20 
 
Figure 17: XBee and Voltage Regulator Schematic 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SAAT Corporation
Your Home Environment Monitoring System       21 
Troubleshooting
 
Issue  Possible Reason  How to fix it 
LCD does not turn on  System is not powered  ­ Check if the power cord is 
connected properly. 
Disconnect and connect it. 
­ Battery out of power, 
replace the battery 
LEDs do not turn on  Measurands and setpoints 
are equal 
­ If the measurands and 
setpoints are equal, the LEDs 
do not turn on. This is not a 
problem 
Wrong measurand readings  Calibration  ­ Power off and power on the 
system again to reset it 
Device disconnected on 
Heroku device cloud 
Device not connected to wifi  ­ Ensure your wifi is open and 
available to connect. If not, 
contact your network 
administrator. 
Cannot log on to device cloud  Wrong username/password  ­ Ensure the correct 
username and password 
­ Contact Heroku Tech. 
Support for further details: 
952­912­3444 
Other unknown issues    Contact us at 631­555­5555 
to report the issue for further 
assistance 
Contact Information
Email 
questions@SAAT.com 
 
Phone 
1­800­888­SAAT(7228) 
 
Mail 
SAAT Corporation 
1, Infinity Way 
Port Jefferson, NY 11790 

Weitere ähnliche Inhalte

Was ist angesagt?

196.21 nvidia control_panel_quick_start_guide
196.21 nvidia control_panel_quick_start_guide196.21 nvidia control_panel_quick_start_guide
196.21 nvidia control_panel_quick_start_guide
Ron McGlothlin
 
Manual Iq Basic E 14 01 2010
Manual Iq Basic E 14 01 2010Manual Iq Basic E 14 01 2010
Manual Iq Basic E 14 01 2010
saxinfo
 
Manual x58 20 super computer
Manual x58 20 super computerManual x58 20 super computer
Manual x58 20 super computer
liourte
 
13fusionhybrid
13fusionhybrid13fusionhybrid
13fusionhybrid
rukford1
 
Acer c300 tmc300sg
Acer c300 tmc300sgAcer c300 tmc300sg
Acer c300 tmc300sg
lukatak
 
Manual mikrotik
Manual mikrotikManual mikrotik
Manual mikrotik
Alex Dau
 
Gt C6112 Um Open Eng Rev 1 1 091117
Gt C6112 Um Open Eng Rev 1 1 091117Gt C6112 Um Open Eng Rev 1 1 091117
Gt C6112 Um Open Eng Rev 1 1 091117
guest609017
 

Was ist angesagt? (17)

Faronics Deep Freeze Server Standard User Guide
Faronics Deep Freeze Server Standard User GuideFaronics Deep Freeze Server Standard User Guide
Faronics Deep Freeze Server Standard User Guide
 
Atv212 programming manual
Atv212 programming manualAtv212 programming manual
Atv212 programming manual
 
196.21 nvidia control_panel_quick_start_guide
196.21 nvidia control_panel_quick_start_guide196.21 nvidia control_panel_quick_start_guide
196.21 nvidia control_panel_quick_start_guide
 
Manual Iq Basic E 14 01 2010
Manual Iq Basic E 14 01 2010Manual Iq Basic E 14 01 2010
Manual Iq Basic E 14 01 2010
 
Manual x58 20 super computer
Manual x58 20 super computerManual x58 20 super computer
Manual x58 20 super computer
 
ASUS MeMO Pad 7 (ME572C) Manual Guide PDF Download (English) / Usr Guide
  ASUS MeMO Pad 7 (ME572C) Manual Guide PDF Download (English) / Usr Guide  ASUS MeMO Pad 7 (ME572C) Manual Guide PDF Download (English) / Usr Guide
ASUS MeMO Pad 7 (ME572C) Manual Guide PDF Download (English) / Usr Guide
 
13fusionhybrid
13fusionhybrid13fusionhybrid
13fusionhybrid
 
Manual lenovo y700
Manual lenovo y700Manual lenovo y700
Manual lenovo y700
 
Acer c300 tmc300sg
Acer c300 tmc300sgAcer c300 tmc300sg
Acer c300 tmc300sg
 
Promass80 flow meter
Promass80 flow meterPromass80 flow meter
Promass80 flow meter
 
The Lenovo Ideapad 100s user guide manual PDF (English)
The Lenovo Ideapad 100s user guide manual PDF (English)The Lenovo Ideapad 100s user guide manual PDF (English)
The Lenovo Ideapad 100s user guide manual PDF (English)
 
Dell Latitude 11 Education Series (3150) Manual PDF (English) / User Guide
Dell Latitude 11 Education Series (3150) Manual PDF (English) / User GuideDell Latitude 11 Education Series (3150) Manual PDF (English) / User Guide
Dell Latitude 11 Education Series (3150) Manual PDF (English) / User Guide
 
Manual mikrotik
Manual mikrotikManual mikrotik
Manual mikrotik
 
C00778901
C00778901C00778901
C00778901
 
E1125 Terminator P4 533 No Pw
E1125 Terminator P4 533 No PwE1125 Terminator P4 533 No Pw
E1125 Terminator P4 533 No Pw
 
Gt C6112 Um Open Eng Rev 1 1 091117
Gt C6112 Um Open Eng Rev 1 1 091117Gt C6112 Um Open Eng Rev 1 1 091117
Gt C6112 Um Open Eng Rev 1 1 091117
 
20him um001 -en-p
20him um001 -en-p20him um001 -en-p
20him um001 -en-p
 

Ähnlich wie EMCS Design Documentation - ESE381

Operational Manual
Operational ManualOperational Manual
Operational Manual
EXSign
 
E1968 p5ad2 e-deluxe
E1968 p5ad2 e-deluxeE1968 p5ad2 e-deluxe
E1968 p5ad2 e-deluxe
luisj9212
 
Honeywell gsmv-install-guide
Honeywell gsmv-install-guideHoneywell gsmv-install-guide
Honeywell gsmv-install-guide
Alarm Grid
 
S6_Guide_80752
S6_Guide_80752S6_Guide_80752
S6_Guide_80752
Rob Wenig
 
Aspire 2930
Aspire 2930Aspire 2930
Aspire 2930
Yan Bali
 
Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...
Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...
Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...
Banking at Ho Chi Minh city
 

Ähnlich wie EMCS Design Documentation - ESE381 (20)

Table of contents
Table of contentsTable of contents
Table of contents
 
Operational Manual
Operational ManualOperational Manual
Operational Manual
 
Smart fademl v1_1_user_manual_reva
Smart fademl v1_1_user_manual_revaSmart fademl v1_1_user_manual_reva
Smart fademl v1_1_user_manual_reva
 
E1968 p5ad2 e-deluxe
E1968 p5ad2 e-deluxeE1968 p5ad2 e-deluxe
E1968 p5ad2 e-deluxe
 
E1968 p5ad2 e-deluxe
E1968 p5ad2 e-deluxeE1968 p5ad2 e-deluxe
E1968 p5ad2 e-deluxe
 
Honeywell gsmv-install-guide
Honeywell gsmv-install-guideHoneywell gsmv-install-guide
Honeywell gsmv-install-guide
 
MSICENTER.pdf
MSICENTER.pdfMSICENTER.pdf
MSICENTER.pdf
 
Parallel sysplex
Parallel sysplexParallel sysplex
Parallel sysplex
 
MK-99DF8208-03
MK-99DF8208-03MK-99DF8208-03
MK-99DF8208-03
 
S6_Guide_80752
S6_Guide_80752S6_Guide_80752
S6_Guide_80752
 
Aspire 2930
Aspire 2930Aspire 2930
Aspire 2930
 
Home Security Systems Reno | DSC powerseries users guide
Home Security Systems Reno | DSC powerseries users guideHome Security Systems Reno | DSC powerseries users guide
Home Security Systems Reno | DSC powerseries users guide
 
Call Detail Recording.pdf
Call Detail Recording.pdfCall Detail Recording.pdf
Call Detail Recording.pdf
 
Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...
Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...
Automated provisioning using ibm tivoli intelligent orchestrator and enterpri...
 
Sony Xperia XZ2 Premium Manual/User Guide
Sony Xperia XZ2 Premium Manual/User GuideSony Xperia XZ2 Premium Manual/User Guide
Sony Xperia XZ2 Premium Manual/User Guide
 
Cockpit esp
Cockpit espCockpit esp
Cockpit esp
 
IBM PureFlex System and IBM Flex System Products and Technology
IBM PureFlex System and IBM Flex System Products and TechnologyIBM PureFlex System and IBM Flex System Products and Technology
IBM PureFlex System and IBM Flex System Products and Technology
 
Redp4469
Redp4469Redp4469
Redp4469
 
Hdclone
HdcloneHdclone
Hdclone
 
Openbravo for Retail Solution Description (RMP19)
Openbravo for Retail Solution Description (RMP19)Openbravo for Retail Solution Description (RMP19)
Openbravo for Retail Solution Description (RMP19)
 

EMCS Design Documentation - ESE381

  • 1.   ¡ ¢ £ ¤ ¥ ¦ ¤ § ¥ ¤ ¨ ¤ ¡ © ¥ § © § §   ¡ ¡ ¡
  • 2. SAAT Corporation Your Home Environment Monitoring System       1  Contents  What is it?…………………………………………………………………………….. 2    In the box …………………………………………………………………………….. 2    Features …………………………………………………………………………….. 2    Top Level Design ……………………………………………………………………. 3    Modular Software ……………………………………………………………………. 4    Local Operation Mode FSM …………………………………………………… 5    Remote Operation Mode FSM …………………………………………………… 8    Keypad …………………………………………………………………………….. 11    EAR DOG Module LCD ……………………………………………………………. 13    Honeywell HumidIcon Temperature and Humidity Sensor …………………. 14    Pressure Sensor …………………………………………………………………….. 16    MAX1270 Analog­to­Digital Converter …………………………………………… 17    XBee Wireless Module ……………………………………………………………. 19    Troubleshooting ……………………………………………………………………..  21    Contact Information ……………………………………………………………. 21               
  • 3. SAAT Corporation Your Home Environment Monitoring System       2  Welcome to your SAAT system    What is it? This system is an Environmental Monitoring and Control System (EMCS) that can  monitor the temperature, humidity and pressure of the room as well as adjust the temperature  and humidity to a set level. Our system has two different operation modes: local mode and  remote mode. In local mode, the measurands can be displayed on an LCD screen built into the  system and the setpoints for temperature and humidity can be modified using the keypad. In  remote mode, the same operations can be executed over the internet remotely from any internet  capable device. This is the biggest advantage of the system.     In the box ● Environmental Monitoring and Control System (EMCS) unit  ● Power adapter (9V output)  ● Control signals connector for AC, Furnace, Humidifier and Dehumidifier    Features ● Read the temperature  ● Read the humidity  ● Read the pressure  ● Set the temperature to control the AC or Furnace  ● Set the humidity to control the humidifier or dehumidifier  ● In­built wifi unit to perform all operations remotely from any internet connected device  ● Optional 9V battery connector for ease of use                 
  • 4. SAAT Corporation Your Home Environment Monitoring System       3  Top Level Design The following are the components of the system:  ­ EA DOGM163A LCD controller and driver  ­ Honeywell HumidIcon Digital Temperature and Humidity Sensor  ­ MPXHZ6130A Pressure Sensor  ­ MAX1270 Analog­to­Digital Converter with SPI  ­ 4x4 Keypad (Some keys are not used for the final design)  ­ XBee Wireless Module  ­ Control signals for AC, Furnace, Humidifier and Dehumidifier    Figure 1: Top level system block diagram  The system uses SPI to communicate with the sensors and the LCD display. RS232  communication protocol is used to send and receive data via the wireless module. The AVR240  design is used for the keypad interface to minimize hardware requirements. The system uses  two separate finite state machines for local operation mode and remote operation mode. Both  the state machines are described in detail below. The schematic of the ATmega128 is attached  in the Appendix. 
  • 5. SAAT Corporation Your Home Environment Monitoring System       4  Modular Software   Figure 2: Modular Program Interaction  The functionality of the EMCS built upon several modules of code that divide and group the tasks  carried out by the system into manageable building blocks. The figure above depicts the primary  functions the EMCS undertakes:  ● Background Tasks ­ involve measuring the current temperature, humidity, and  pressure, and displaying them to the LCD. The measured values are also  compared against the set point values set by the user to determine if system  needs to turn on or off the AC, furnace, humidifier, and/or dehumidifier.  ● Finite State Machines ­ EMCS switches between two FSM depending on which  mode the EMCS is currently operation in. Each mode is designed to expose the  user to  different I/O capabilities of the EMCS. Thus improving the versatility of  system  ● Interrupt Driven ­ the interrupt service routines allow for the handling of I/O from  the user through their use of the keypad, or a terminal when the EMCS is wireless  mode.   The remote_op_emcs.c located in the appendix us driver program for the EMCS. The  program interacts with the modules max1720.c and baro_pressure.c to communicate with the  MAX1270 to retrieve the barometric pressure. The program interacts with humidicon_task2 and  temp_humid_humidicon to communicate with the Humidicon to retrieve both temperature and  relative humidity. The program is able to display characters on the LCD due to the interaction to  lcd_etc. and log_dog_iar_driver.asm The USART2.c contains the ISR (interrupt service routine)  which stores received characters in the receive buffer, and transmits characters in the transmit  buffer out.  
  • 6. SAAT Corporation Your Home Environment Monitoring System       5  Local Operation Mode FSM This Finite State Machine implements the operations of the EMCS in Local operation  mode. The keypad is used for user input and the LCD display is used for output. This system  allows the user to change the setpoints for the temperature (ST) and the humidity (SH). The  setpoints can be modified one of two ways; by pressing the up or down keys on the keypad, or  by directly inputting the tens, units and decimal digits on the keypad, in that order. Following is a  description of the states and functions of the local finite state machine.    Local FSM States:  ● Select_temp ­ This is the default state of this finite state machine. In this state, the  cursor (#) is displayed next to the temperature setpoint on the display. This indicates that,  the setpoint for the temperature can be modified by pressing the 2nd key on the keypad.   ● Select_hum ­ Displays the cursor (#) next to the humidity setpoint. This allows the user  to modify the setpoint for humidity by pressing the 2nd key on the keypad.  ● Set_temp ­ This state allows to modify the setpoint for temperature. There are two ways  of doing this. By using the up or down keys on the keypad, or by directly inputting the  digits for the setpoint. This state advances based on the first input from the user. Using  the up or down key modifies the measurand in 0.1 increments  ● Set_hum ­ This state allows to modify the setpoint for temperature. There are two ways  of doing this. By using the up or down keys on the keypad, or by directly inputting the  digits for the setpoint. This state advances based on the first input from the user. Using  the up or down key modifies the measurand in 0.1 increments  ● Tens_T ­ Upon entering the first digit in set_temp state, tens_T waits for the next digit to  be put in the units place.  ● Units_T ­ This state waits for decimal digit to be input on the keypad.  ● Dec_T ­ This state waits for the Enter key to be pressed and then updates the  temperature setpoint of the EMCS and updates the display accordingly.  ● Tens_H ­ Upon entering the first digit in set_hum state, tens_H waits for the next digit to  be put in the units place.  ● Units_H ­ This state waits for decimal digit to be input on the keypad.  ● Dec_H ­ This state waits for the Enter key to be pressed and then updates the humidity  setpoint of the EMCS and updates the display accordingly.    Local FSM Functions:  ● move_cursor_hum ­ Set the variable boolean hashtag equal to 0. The main function  then used this variable to display the cursor next to the humidity setpoint.  ● move_cursor_temp ­ Set the variable boolean hashtag equal to 1. The main function  then used this variable to display the cursor next to the temperature setpoint.  ● increment_ST ­ Incremented the value of the temperature setpoint by 0.1 degrees.  ● decrement_ST ­ Decremented the value of the temperature setpoint by 0.1 degrees.  ● update_ST ­ Set the flag, entered, equal to 1, enabling the main program to update the  temperature setpoint displayed on the LCD display. 
  • 7. SAAT Corporation Your Home Environment Monitoring System       6  ● increment_SH ­ Incremented the value of the humidity setpoint by 0.1%.  ● decrement_SH ­ Decremented the value of the humidity setpoint by 0.1%.  ● update_SH ­ Set the flag, entered, equal to 1, enabling the main program to update the  humidity setpoint displayed on the LCD display.  ● process_digit ­ Depending on the current state of the state machine, this function used  the keycode value obtained from the keypad to change the respective digit of the  temperature or humidity setpoints. It then updated the value of the global variables for the  two setpoints.  ● do_nothing ­ This function does nothing in the state machine and simply prints “Do  Nothing”. This function is used for testing and debugging the state machine.       
  • 9. SAAT Corporation Your Home Environment Monitoring System       8  Remote Operation Mode FSM This Finite State Machine implements the operations of the EMCS in Local operation  mode. The commands are transmitted and data is received through an XBee module using  RS232 protocol. The following is the command set for the EMCS in remote operation mode:    To set temperature: ST=dd.d  To set humidity: SH=dd.d  To read temperature: T  Response is: T=dd.d  To read humidity: H  Response is: H=dd.d  To read pressure: P  Response is: P=dd.dd  where d is a digit 0­9.    Commands sent by the device cloud are wrapped by a Return Carriage char ‘/r’. Following is the  description of the remote FSM:    Remote FSM States:  ● display ­ Initial state of the system that waits for an incoming command to be executed.  The input command is saved in a buffer to be able to be accessed later in the system.  ● send_temp ­ When the carriage return char ‘/r’ is received, this state returns the  temperature and goes back to the initial state display.  ● send_pressure ­ When the carriage return char ‘/r’ is received, this state returns the  pressure and goes back to the initial state display.  ● send_humidity ­ When the carriage return char ‘/r’ is received, this state returns the  humidity and goes back to the initial state display.  ● process_second ­ If the first character received was an ‘S’, the following command  must be modifying one of the setpoints. This state waits for the second character to  determine if temperature setpoint or the humidity setpoint is to be modified.  ● wait_H ­ This state waits for an ‘=’ character.  ● tens_H ­ This state indicates that the next character received is the tens digit of the  humidity setpoint. The present state variable is used by the process_digit function to  determine what position the digit is in.  ● ones_H ­ This state indicates that the next character received is the units digit of the  humidity setpoint.  ● dot_H ­ Waits for a decimal point to be entered after the units digit.  ● stay_H ­ Waits for a valid digit to be entered for the decimal digit of humidity setpoint.  ● decimal_H ­ Waits for a carriage return character to update the humidity setpoint and  return to the initial state of the system.  ● wait_T ­ This state waits for an ‘=’ character. 
  • 10. SAAT Corporation Your Home Environment Monitoring System       9  ● tens_T ­ This state indicates that the next character received is the tens digit of the  temperature setpoint.  ● ones_T ­ This state indicates that the next character received is the units digit of the  temperature setpoint.  ● dot_T ­ Waits for a decimal point to be entered after the units digit.  ● stay_T ­ Waits for a valid digit to be entered for the decimal digit of temperature setpoint.  ● decimal_T ­ Waits for a carriage return character to update the temperature setpoint and  return to the initial state of the system.      Remote FSM Functions:  ● save_command ­ Saves the incoming character in a buffer to be accessed later.  ● return_temp ­ Sends the temperature measurement out to the remote station in the  format: T=dd.d.  ● return_pressure ­ Sends the pressure measurement out to the remote station in the  format: P=dd.dd.  ● return_hum ­ Sends the humidity measurement out to the remote station in the format:  H=dd.d.  ● process_digitR ­ Depending on the present state of the machine, this function used the  digit to update the respective digits of one of the setpoint values.   ● send_SH ­ The new humidity setpoint is updated and displayed on the LCD screen on  the device.  ● send_ST ­ The new temperature setpoint is updated and displayed on the LCD screen  on the device. 
  • 12. SAAT Corporation Your Home Environment Monitoring System       11  Keypad A 4x4 keypad is used to get input from the user in local operation mode. The keypad is used to  modify the setpoints for the temperature and humidity measurands. The AVR240 design is used  to achieve keypad scanning using minimal hardware.        Figure 5: Keypad Scanning Design  Courtesy: AVR240 application notes  In this design, the rows are connected to the lower nibble of Port C and the columns are  connected to the higher nibble of Port C. Initially the pins of the higher nibble are set up as  outputs writing a logic ‘0’. Pins of the lower nibble are set up as inputs with internal pull up  resistors enabled. INT0 is enabled to trigger on a falling edge. When a key is pressed, the row  and column of that key are connected together. This pulls down the logic on that pin to a logic ‘0’  calling the interrupt service routine. The service routine then scans through the lower nibble of  Port C to determine the row of the pressed key. Then, the direction of the pins of Port C are  swapped. The higher nibble of Port C is scanned to determine the column of the key pressed.  The combination of this row and column number is assigned a specific key value. This key value  is then used to look up a table for the keycode of the key that was pressed.  
  • 14. SAAT Corporation Your Home Environment Monitoring System       13  EAR DOG Module LCD The EAR DOG Module DOGM163W­A used in this system is a SPI LCD display  controller and driver with a 3 line 16 character dot matrix LCD panel. The controller has two 8­bit  registers, the instruction register (IR) and the data register (DR). The controller has parallel  interface but it is also SPI compatible. In this system SPI is used to write to the display. The  Register Select input (RS) selects the IR when RS = 0 and the DR when RS = 1. The IR stores  instruction codes and address information for the DDRAM and Character Generator RAM  (CGRAM). The DR holds the data to be written to the DDRAM or CGRAM. The address counter  register (AC) holds the address of the locations in DDRAM or CGRAM.     Figure 7: LCD DOG Module connections  Courtesy: Professor Kenneth Short’s lecture slides  The MOSI and SCK signals of the DOG module are shared by other SPI peripherals in the  system. The RS signal is connected to the PB4 of the ATmega128. The LCD chip select signal  (/SS) is connected to PB0. These connections are made using a JTAG connector shown below.    Figure 8: LCD JTAG Connector   
  • 15. SAAT Corporation Your Home Environment Monitoring System       14  Honeywell HumidIcon Temperature and Humidity Sensor This design uses a Honeywell HIH9000 series SOIC­8 SMD with serial output. This  sensor is a combined temperature and humidity sensor with 14­bit resolution. In a measurement  cycle, the sensor is normally in power down mode. To wake the sensor and make a  measurement, a Measurement Request (MR) command is used. A MR command is an 8­bit  read and then incoming data is ignored. A Data Fetch (DF) command is then used to read the  temperature and/or humidity.    Figure 9: HumidIcon Measurement Cycle  Courtesy: Professor Kenneth Short’s Lecture Slides  The sensor is a Read only device and uses the shared MISO input from the  microcontroller. Pin PortA 0 is used as a select signal for the sensor. A data fetch packet  returned from the humidicon has the following format: [ {S(1:0),C(13:8)}, {C(7:0)}, {T(13:6)},  {T(5:0),xx} ] where,  S(1:0) = Status bit of the packet (00 ­ normal operation, valid data; 01 ­ stale data, no new data)  C(13:8) = Upper six bits of the 14­bit humidity   C(7:0) = Lower eight bits of the 14­bit humidity  T(13:6) = Upper eight bits of the 14­bit temperature  T(5:0) = Lower 6 bits of the 14­bit temperature  xx = don’t care.    Figure 10: Humidicon Data packet  Courtesy: Professor Kenneth Short’s Lecture Slides  Hence, a complete measurement of both temperature and humidity takes a total of four SPI  transfer cycles. This raw data is then scaled and converted to the required units to be displayed.  
  • 16. SAAT Corporation Your Home Environment Monitoring System       15    Figure 11: HumidIcon Schematic    Conversion and Scaling of Raw Data  1. The four data packets are stored in 4 separate unsigned integers. Using the above  notation, C(13:8), C(7:0), T(13:6), T(5:0) are to be stored in separate variables C1, C2,  T1, T2, respectively.  2. Mask the C1 with 0x3F to eliminate the two unnecessary MSB of C1 that do not contain  the value of the raw humidity.  3. Mask T2 with 0xFC to eliminate the two unnecessary LSB of T2 that do not contain the  value of the raw temperature.  4. Shift C1 to right 8 positions to place the high nibble of the raw humidity into the MSBs.  5. Shift T1 to the right 8 positions to place the high bible of the raw temperature into the  MSBS.  6. Performing a bitwise OR of C1 and C2 will yield the complete raw value of Humidity.  7. Performing a bitwise OR of T1 and T2 will yield the complete raw value of temperature,  after the OR result is shifted to the left two position.             (1)caled Temperature  000S =   2 −214 Raw Temperture   100 165* * − 4                                      (2)caled Humidity    S = 2 −214 Raw Hiumidity 100 100* *     See files humidion _task2.c and temp_humid_humdicon.c in the appendix to see process  executed in C.               
  • 17. SAAT Corporation Your Home Environment Monitoring System       16  Pressure Sensor The transducer used in this system is a Freescale MPXHZ6130A Pressure sensor. This  sensor has a 1.5% accuracy over 0 degrees to 85 degrees Celsius. It comes in a surface mount  package and is suitable for microcontroller based systems. The basic characteristics of the  sensor are shown in the table below from the datasheet:  Figure 12: MPXHZ6130A Pressure Sensor Characteristics  Courtesy: MPXHZ6130A Datasheet  The analog output of this sensor is connected an Analog­to­Digital converter.    Figure 13: MPXHZ6130A Schematic       
  • 18. SAAT Corporation Your Home Environment Monitoring System       17  MAX1270 Analog-to-Digital Converter The MAX1270 is a Data­Acquisition­System (DAS) IC that has a multiplexer, to switch  between input channels, signal conditioning circuit for gain and offset adjustment, and an  Analog­to­Digital converter with Voltage reference. It allows up to eight analog input channels. It  has a 12­bit resolution with 0.5 LSB linearity Our system uses a SPI enabled version to save port  pins on the microcontroller. This is used to convert the analog pressure sensor output to a digital  output to be monitored and used by the microcontroller. Channel 0 analog input is used in our  system.   To initiate a conversion, a Control Byte needs to be transmitted. The control byte selects  the input channel for a particular conversion, selects the full scale input voltage range, unipolar or  bipolar modes, and the clock and power down mode. The control byte has the following format:  CB = {Start, SEL2, SEL1, SEL0, RNG, BIP, PD1, PD0}  Bit 7 ­ Start: First logic 1 after the /CS goes low defines the beginning of a control byte.  Bit 6:4 ­ Select bits: The three bits select the desired analog input channel.  Bit 3 ­ Range: Selects the full scale voltage range for the conversion. (Table __)  Bit 2 ­ Bip: Unipolar or Bipolar operation mode (Table __)  Bit 1:0 ­ Power Down mode: 00 for normal operation (always on) with internal clock.      Table 1: Range and Polarity selection for MAX1270  Courtesy: MAX1270 Datasheet    The timing waveform below from the MAX1270 datasheet shows the detailed timing  requirements. After the Chip Select input (/CS) signal goes low, the control byte for a conversion  is transmitted. After the transfer of the control byte, the chip is to be unselected (/CS=1). This  sets the Strobe signal (SSTRB) to a logic 0 indicating the start of a conversion. The end of  conversion is indicated by the SSTRB signal going high. Once the SSTRB signal goes high, our  design transfers two dummy bytes over the MOSI line to read the 12­bit ADC output over the  MISO line. For faster continuous conversion cycles, a second control byte can be transferred  after the first dummy byte to initiate another conversion. However, our system does a total of  three byte transfers, one control byte and two dummy bytes. At the end of the second dummy  byte, the chip is deselected. INT1 of the microcontroller is used to trigger an interrupt service  routine when end of conversion signal occurs on the SSTRB. 
  • 20. SAAT Corporation Your Home Environment Monitoring System       19  XBee Wireless Module The XBee 802.15.4 wireless transmitter/receiver converts RS232 protocol signals into a  wireless RS232 protocol data stream. In remote operation mode of the EMCS, the XBee is used  to receive commands from a remote station and send data back. This enables the setting of  temperature and humidity setpoints from any internet capable device. The ATmega128 uses  USART0 to communicate with the XBee module. The base station sends out a command  through the USART, which then goes to the XBee for wireless transmission. A remote station is  also able to send commands back to the base station through a device cloud that is integrated  with the XBee. The Heroku cloud application platform provides for customized device cloud  capabilities. The XBee module comes with its own device cloud. Logging into the Heroku device  cloud for XBee gives us loads of capabilities via widgets to communicate with the XBee. Our  system uses a simple text interface that is able to send and receive data from the XBee module  over the internet.     The Xbee needs a 3.3V power supply. Since this system is primarily 5V, a voltage  regulator is used to convert 5V down to 3.3V. Because the XBee is operating at 3.3V, it cannot  be directly connected to the ATmega128. The voltage and current characteristics of both the  devices need to be compatible. The XBee RxD input from the microcontroller is connected to a  voltage divider to limit the voltage.     Figure 16: XBee ­ ATmega128 Compatibility Requirements  Courtesy: Professor Kenneth Short’s Lecture Slides   
  • 22. SAAT Corporation Your Home Environment Monitoring System       21  Troubleshooting   Issue  Possible Reason  How to fix it  LCD does not turn on  System is not powered  ­ Check if the power cord is  connected properly.  Disconnect and connect it.  ­ Battery out of power,  replace the battery  LEDs do not turn on  Measurands and setpoints  are equal  ­ If the measurands and  setpoints are equal, the LEDs  do not turn on. This is not a  problem  Wrong measurand readings  Calibration  ­ Power off and power on the  system again to reset it  Device disconnected on  Heroku device cloud  Device not connected to wifi  ­ Ensure your wifi is open and  available to connect. If not,  contact your network  administrator.  Cannot log on to device cloud  Wrong username/password  ­ Ensure the correct  username and password  ­ Contact Heroku Tech.  Support for further details:  952­912­3444  Other unknown issues    Contact us at 631­555­5555  to report the issue for further  assistance  Contact Information Email  questions@SAAT.com    Phone  1­800­888­SAAT(7228)    Mail  SAAT Corporation  1, Infinity Way  Port Jefferson, NY 11790