SlideShare ist ein Scribd-Unternehmen logo
1 von 6
Downloaden Sie, um offline zu lesen
This article appeared in a journal published by Elsevier. The attached
copy is furnished to the author for internal non-commercial research
and education use, including for instruction at the authors institution
                    and sharing with colleagues.
   Other uses, including reproduction and distribution, or selling or
 licensing copies, or posting to personal, institutional or third party
                       websites are prohibited.
   In most cases authors are permitted to post their version of the
     article (e.g. in Word or Tex form) to their personal website or
    institutional repository. Authors requiring further information
      regarding Elsevier’s archiving and manuscript policies are
                           encouraged to visit:
                  http://www.elsevier.com/copyright
Author's personal copy

                                       j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4



                                               Available online at www.sciencedirect.com




                                     journal homepage: www.elsevier.com/locate/JOPR



Original Article

Simple RP-HPLC method for estimation of diazepam in tablet
dosage form

A. Sruthi, P. Tejaswi, N. Thanuja, D. Sudheer Kumar, P. Vivek Sagar*
Department of Pharmaceutical Analysis, Care College of Pharmacy, Warangal, Andhra Pradesh, India



article info                                  abstract

Article history:                              A simple reverse phase HPLC method was developed and validated for the determination
Received 11 September 2012                    of diazepam present in pharmaceutical dosage form. A Hypersil ODS C-18 column
Accepted 4 November 2012                      (250 Â 4.6 mm, packed with 5 microns) is used as stationary phase. An isocratic mode with
                                              mobile phase consisting of acetonitrile, methanol and 1% phosphate buffer (pH-3) in ratio
Keywords:                                     of 18:58:24 (v/v/v) at a flow rate of 1 ml/min and effluent was monitored at 232 nm.
RP-HPLC                                       Chromatogram showed a peak of DZP at retention time of 6.23 Æ 0.002 min. The linearity
Diazepam                                      range was found to be 2e20 mg/ml. The method was validated for linearity, accuracy,
Validation                                    precision, limit of detection, limit of quantitation, robustness and ruggedness. Recovery of
Pharmaceutical dosage form                    DZP was found to be in the range of 99.4e100.3%. The limit of detection and limit of
                                              quantitation for estimation of DZP was found to be 0.898 mg/ml and 2.72 mg/ml, respectively.
                                              Proposed method was successfully applied for the quantitative determination of DZP in
                                              pharmaceutical dosage forms.
                                                      Copyright ª 2012, JPR Solutions; Published by Reed Elsevier India Pvt. Ltd. All rights
                                                                                                                                  reserved.




1.        Introduction                                                         expensive. The present study focused on minimizing these
                                                                               limitations and to develop a simple precise accurate and
Diazepam (7-chloro-1, 3-dihydro-1-methyl-5-phenyl-2H-1,                        economic method for estimation of diazepam in tablet dosage
4-benzodiazepin-2-one) is a benzodiazepine (BZD) generally                     form.
used as hypnotic, anxiolytic and muscle relaxant. Diazepam
(DZP) is also routinely prescribed as the standard first-line
treatment for acute convulsions and prolonged status epi-
lepticus.1 Several methods for the analysis of BZDs have been
reported.2 A number of chromatographic methods, such as
thin-layer chromatography (TLC)3 gas chromatography4e6 and
gas chromatographicemass spectrometry (GCeMS)7,8 have
been used in the analysis of diazepam and other 1,4-benzo-
diazopines. Several high-performance liquid chromato-
graphic (HPLC) methods have also been reported for the
determination of diazepam and other BZDs.9,10 However, all of
these methods have limitations such as long run times and/or


 * Corresponding author.
   E-mail address: viveksagar.p111@gmail.com (P. Vivek Sagar).
0974-6943/$ e see front matter Copyright ª 2012, JPR Solutions; Published by Reed Elsevier India Pvt. Ltd. All rights reserved.
http://dx.doi.org/10.1016/j.jopr.2012.11.029
Author's personal copy

                                      j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4                           141


                                                                              2.4.        Preparation of working standard solutions
2.      Materials and methods
                                                                              Working standard solutions ranging from 0.5 to 50 mg/ml were
2.1.    Chemicals and reagents                                                prepared by appropriate dilutions of the stock with distilled
                                                                              water.
An analytically pure sample of diazepam was procured as
gift sample from Natco Pharma Ltd. (Hyderabad, India).                        2.5.        Preparation of sample solution
HPLC grade methanol was procured from E. Merck (Hyder-
abad). Liquid chromatographic grade water was obtained by                     Twenty tablets of diazepam hydrochloride were weighed and
double distillation and purification through Milli-Q water                     ground into a fine powder. A quantity of powder equivalent to
purification system. Potassium dihydrogen phosphate (AR                        25 mg of diazepam was weighed and transferred into a 25 ml
grade, purity 99.5%) was procured from Qualigens. Tablet                      volumetric flask and was dissolved in 0.1 N HCl. The volume
formulations VALIUM (Nicholas Piramal India Ltd.) was                         was made up to the mark with the same. Above solution was
procured from a local pharmacy with labeled amount 5 mg                       suitably diluted with distilled water. From this stock, appro-
per tablet.                                                                   priate dilution (10 mg/ml) was prepared. The solution thus
                                                                              prepared was filtered through 0.45 m membrane filter and the
2.2.    Instrumentation & chromatographic conditions                          resulting filtrate was sonicated for 10 min. After setting the
                                                                              chromatographic conditions and stabilizing the instrument to
The HPLC analysis was performed on CYBERLAB HPLC                              obtain a steady baseline, the sample solution was loaded in
equipped with an LCP-100 reciprocating HPLC pump. A                           the 20 ml fixed e sample loop of the injection port.
manually operating Rheodyne injector with 20 mL sample
loop, a LC-UV 100 ultraviolet detector was used. Chromato-                    2.6.        Method development
graphic analysis was performed on a Hypersil reversed phase
C-18 column with 250 Â 4.6 mm i.d. and 5 mm particle size.                    Initial trial experiments were conducted, with a view to select
The mobile phase consist of acetonitrile, methanol, 1%                        a suitable solvent system for the accurate estimation of the
phosphate buffer (pH-3) in ratio of 18:58:24 (v/v/v) that was set             drug and to achieve good retention time. The suitability of the
at a flow rate of 1 ml/min. The mobile phase was degassed                      mobile phase decided on the basis of the sensitivity of the
and filtered through 0.25 mm membrane filter before pumping                     assay, time required for the analysis, ease of preparation, and
into HPLC system. The eluent was monitored by UV detection                    use of readily available cost effective solvents. These include
at 232 nm.                                                                    methanol-potassium dihydrogen phosphate, methanol-
                                                                              ammonium acetate, acetonitrile-potassium dihydrogen phos-
2.3.    Stock solutions and standards                                         phate, acetonitrile-ammonium acetate, methanol-water. The
                                                                              mobile phase consisting of acetonitrile, methanol, 1% phos-
Stock solution of diazepam (1 mg/ml) was prepared by                          phate buffer (pH-3) in ratio of 18:58:24 (v/v/v) that was set at
transferring 25 mg of drug in a 25 ml volumetric flask. The                    a flow rate of 1 ml/min was found to be optimum and further
drug is dissolved in sufficient amount of 0.1 N HCl and                        optimized by adjusting pH 3e4 by adding orthophosphoric acid.
finally the volume was made up to the mark with distilled                      The composition of acetonitrile, methanol, 1% phosphate
water.                                                                        buffer in ratio of 18:58:24 (v/v/v) with pH-3 gave the best results.




                                                Fig. 1 e Chromatogram of diazepam.
Author's personal copy

142                                   j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4




 Table 1 e Linearity of diazepam.                                               Table 2 e Precision.
 S. No                Concentration                     Peak area               S. No                       Concentration        Peak area
                         (ppm)                                                                                 (ug/ml)

 1                             2                            7569.8              1                                    6            21709.4
 2                             4                           17892.9              2                                    6            21627.7
 3                             6                           23612.2              3                                    6            21939.6
 4                             8                           34517.2              4                                    6            21710.5
 5                            10                           40051.3              5                                    6            21337.9
 6                            12                           47631.9              6                                    6            21929.5
 7                            14                           54925.1              Mean                                              21709.1
 8                            16                           65942.9              % RSD                                                 1.02
 9                            18                           72965.0
 10                           20                           80440.3

                                                                              triplicate.11 20 ml of each of standard solutions were injected
                                                                              into the HPLC system to get the chromatograms. The retention
2.7.     Solution stability
                                                                              time, average peak areas were recorded. Calibration curve was
                                                                              constructed by plotting average peak area against concentra-
In order to demonstrate the stability of both standard and
                                                                              tion and regression equation was computed. The linearity
sample solutions during analysis, both solutions were analyzed
                                                                              range was found to be 2e20 mg/ml. The results were shown in
over a period of 96 h at an interval of 24 h at room temperature.
                                                                              Table 1. The results show that an excellent correlation exists
The results show that for solutions, the retention time and peak
                                                                              between peak area and concentration of drug within the
area of diazepam hydrochloride remained unchanged and no
                                                                              concentration range, regression graph is presented in Fig. 2.
significant degradation within the indicated period, this indi-
cates that both solutions were stable for 72 h.
                                                                              3.2.2.      Precision
                                                                              The precision of method was ascertained from the peak area
                                                                              response obtained by actual determination of six replicates of
3.       Results and discussion                                               a fixed amount of drug. The percent relative standard devia-
                                                                              tions were calculated for diazepam and presented in the Table
3.1.     Analysis of formulation                                              2. The precision of the method was found to be 1.02.

The sample solution was injected and a chromatogram was                       3.2.3.      Accuracy
recorded. The injections were repeated six times and the peak                 Accuracy of developed method was confirmed by doing
areas were recorded. The amount of drug present in the                        recovery study as per ICH norms. A known quantity of the
pharmaceutical formulation was calculated using standard                      pure drug was added to the pre-analyzed sample formulation
calibration curve (concentration in mg/ml was taken on X-axis                 (10 mg/ml) at three different concentration levels 80%, 100%
and average peak area on Y-axis). Percentage of drug present                  and 120% by replicate analysis (n ¼ 3). From the recovery study
in each tablet was found to be 100.2. A representative chro-                  it was clear that the method is very accurate for quantitative
matogram has been given in Fig. 1.                                            estimation of diazepam hydrochloride in tablet dosage form
                                                                              as all the statistical results were within the range of accep-
3.2.     Validation of the assay method                                       tance, 99.4e100.3%, which shows that there is no interference
                                                                              with excipients. Percentage recovery values were calculated
3.2.1.   Linearity                                                            and the results were shown in Table 3.
Different concentrations in the range of 0.5e50 mg/ml were
prepared. Each of the levels of concentration was prepared in                 3.2.4.      Ruggedness
                                                                              Ruggedness is the degree of reproducibility of the results ob-
                                                                              tained under a variety of conditions. From stock solution,
                                                                              solutions containing 14 mg/ml of diazepam hydrochloride
                                                                              was prepared and analyzed by two different analysts using
                                                                              same operational and environmental conditions in different




                                                                                Table 3 e Accuracy.
                                                                                Amount of                        Amount of      Average %
                                                                                drug added                     drug recovered    recovery
                                                                                (ppm)                              (ppm)

                                                                                8                                     7.592         99.4
                                                                                10                                    9.98          99.8
                                                                                12                                   12.096        100.3
               Fig. 2 e Linearity of diazepam.
Author's personal copy

                                        j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4                             143



 Table 4 e Ruggedness.                                                            Table 7 e System suitability parameters.
                                Date                    % Recovery                Drug               RT         Peak      Peak    USP plate    USP
                                                                                                                area     height    count      tailing
 Analyst-1                      Day-1                       100.2%
 Analyst-2                      Day-2                        99.8%                Diazepam         6.2266      31432.2    2588     5238.42      1.1
 % Deviation                                                  0.4%


                                                                                accuracy and precision. The requirements for system suit-
                                                                                ability are usually developed after method development and
 Table 5 e Robustness.                                                          validation has been completed. The system suitability
                                                                                parameters like Theoretical plates (N), Resolution (R), Tailing
 S. No             Wavelength 232                 Wavelength 235
                                                                                factor (T) were calculated and compared with the standard
 1                     52156.6                         54973                    values to ascertain whether the proposed RP-HPLC method for
 2                     52700.8                         52955.4                  the estimation of diazepam in pharmaceutical formulations
 3                     50662.6                         52965.9                  was validated or not. The results were shown in Table 7.
 4                     50905.7                         54751.1
 5                     51418.4                         54821.7
 6                     50911.8                         52886.1
 Mean                  51459.32                        53892.22                 4.          Conclusion
 % RSD                     1.57                            1.94
                                                                                A convenient, rapid, accurate, precise and economical RP-
                                                                                HPLC method has been developed for estimation of diazepam
experimental periods. Percentage recoveries of the replicates
                                                                                in bulk and tablet dosage form. The assay provides a linear
were calculated. It is checked that the results are reproducible
                                                                                response across a wide range of concentrations and it utilizes
under differences in, analysts. The results are shown in Table 4.
                                                                                a mobile phase which can be easily prepared and diluent is
                                                                                economic, readily available. The proposed method can be
3.2.5.   Robustness
                                                                                used for the routine analysis of diazepam hydrochloride in
The method was found to be robust, although small deliberate
                                                                                bulk preparations of the drug and, in pharmaceutical dosage
changes in method conditions did have a negligible effect on
                                                                                forms without interference of excipients.
the chromatographic behavior of the solute. The results
indicate that changing the detector wavelength had no large
effect on the chromatographic behavior of diazepam hydro-
chloride. Even a small change of mobile phase composition
                                                                                Conflicts of interest
(pH 3 Æ 0.2), did not cause a notable change in the peak area of
                                                                                All authors have none to declare.
the used drug for this method. The results were presented in
Tables 5 and 6.
                                                                                references
3.2.6.   LOD & LOQ
LOD and LOQ for diazepam were estimated by injecting
a series of dilute solutions with known concentration. The
                                                                                  1. Crawley J, Smith S, Kirkham F, Muthinji P, Waruiru C,
parameters LOD and LOQ were determined on the basis of                               Marsh K. Seizure activity and neurological sequelae in
peak response and slope of the regression equation. The LOD                          Ugandan children who have survived an episode of cerebral
and LOQ of the drug were found to be 0.898 mg/ml and 2.72 mg/                        malaria. QJM. 1996;89:591.
ml respectively.                                                                  2. Rouini Mohammad-Reza, Ardakani Yalda H,
                                                                                     Moghaddam Kambiz A, Solatani F. An improved HPLC
                                                                                     method for rapid quantitation of diazepam and its major
3.2.7.   System suitability parameters
                                                                                     metabolites in human plasma. Talanta. 2008;75:671.
System suitability parameters can be defined as tests to                           3. van der Merwe PJ, Steyn JM. Rapid and simple
ensure that the method can generate results of acceptable                            chromatographic method for the determination of diazepam
                                                                                     and its major metabolites in human plasma and urine.
                                                                                     J Chromatogr. 1978;148:549.
                                                                                  4. Gjerde H, Dahlin E, Christophersen AS. Clinical impairment of
 Table 6 e Robustness.                                                               benzodiazepinesdrelation between benzodiazepine
                                                                                     concentrations and impairment in apprehended drivers.
 S. No         Mobile phase pH: 3.0        Mobile phase pH: 3.2                      J Pharm Biomed Anal. 1992;10:317.
 1                  54247.2                         52156.6                       5. Fisher LE, Perch S, Bonfiglio MF, Geers SM. Simultaneous
 2                  53976.3                         52700.8                          determination of midazolam and flumazenil concentrations
 3                  53176.6                         50662.6                          in human plasma by gas chromatography. J Chromatogr
 4                  53315.8                         50905.7                          Biomed Appl. 1995;665:217.
 5                  53346.8                         51418.4                       6. Herraez-Hernandez R, Louter AJ, Van de Merbel NC,
 6                  53758.8                         50911.8                          Brinkman UA. Automated on-line dialysis for sample
 Mean               53636.92                        51459.32                         preparation for gas chromatography: determination of
 % RSD                  0.669                           1.43                         benzodiazepines in human plasma. J Pharm Biomed Anal.
                                                                                     1996;14:1077.
Author's personal copy

144                                    j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4



7. Hold K, Crouch DJ, Rollins DE, et al. Quantitation of alprazolam                performance liquid chromatography analysis. J Chromatogr B.
   and hydroxyalprazolam in human plasma by negative ion                           2001;750:177.
   chemical ionization GC/MS. J Mass Spectrom. 1996;31:1033e1038.              10. Wilhelm M, Battista HJ, Obendorf D. HPLC with simultaneous
8. Borrey D, Meyer E, Lambert W, Van Calenbergh S, Van                             UV and reductive electrochemical detection at the hanging
   Peteghem C, De Leenheer AP. Enzymatic hydrolysis improves                       mercury drop electrode: a highly sensitive and selective tool
   the sensitivity of emit screening for urinary benzodiazepines.                  for the determination of benzodiazepines in forensic
   J Chromatogr A. 2001;910:105.                                                   samples. J Anal Toxicol. 2001;25:250.
9. Bolner, Tagliaro F, Lomeo A. Optimised determination of                     11. Validation of Analytical Procedure: Methodology, ICH Harmonized
   clobazam in human plasma with extraction and high-                              Tripartite Guideline. 1996.

Weitere ähnliche Inhalte

Was ist angesagt?

Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...SriramNagarajan18
 
VAIBHAV presentation final
VAIBHAV presentation finalVAIBHAV presentation final
VAIBHAV presentation finalVAIBHAV BHATT
 
Method Development and Validation of the Simultaneous Determination of Omepra...
Method Development and Validation of the Simultaneous Determination of Omepra...Method Development and Validation of the Simultaneous Determination of Omepra...
Method Development and Validation of the Simultaneous Determination of Omepra...Alok Singh
 
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...Alok Singh
 
Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacy
 Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacy Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacy
Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacysaathiyaa
 
Analytical method development and validation for the estimation of Nimesulide...
Analytical method development and validation for the estimation of Nimesulide...Analytical method development and validation for the estimation of Nimesulide...
Analytical method development and validation for the estimation of Nimesulide...SriramNagarajan18
 
Multiple Method Development and Validation for Simultaneous Estimation of Chl...
Multiple Method Development and Validation for Simultaneous Estimation of Chl...Multiple Method Development and Validation for Simultaneous Estimation of Chl...
Multiple Method Development and Validation for Simultaneous Estimation of Chl...ijtsrd
 
Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...
Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...
Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...SriramNagarajan15
 
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...Ratnakaram Venkata Nadh
 
Diazo coupling for the determination of selexipag by visible spectrophotometry
Diazo coupling for the determination of selexipag by visible spectrophotometryDiazo coupling for the determination of selexipag by visible spectrophotometry
Diazo coupling for the determination of selexipag by visible spectrophotometryRatnakaram Venkata Nadh
 
Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...
Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...
Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...pharmaindexing
 
Stability indicating rp hplc method for the determination of candisartan
Stability indicating rp hplc method for the determination of candisartanStability indicating rp hplc method for the determination of candisartan
Stability indicating rp hplc method for the determination of candisartansrirampharma
 
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...SriramNagarajan15
 
Y01062155162
Y01062155162Y01062155162
Y01062155162iosrjce
 
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...pharmaindexing
 
Analytical method development and validation for the estimation of quinapril ...
Analytical method development and validation for the estimation of quinapril ...Analytical method development and validation for the estimation of quinapril ...
Analytical method development and validation for the estimation of quinapril ...SriramNagarajan19
 

Was ist angesagt? (18)

Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...
 
VAIBHAV presentation final
VAIBHAV presentation finalVAIBHAV presentation final
VAIBHAV presentation final
 
Method Development and Validation of the Simultaneous Determination of Omepra...
Method Development and Validation of the Simultaneous Determination of Omepra...Method Development and Validation of the Simultaneous Determination of Omepra...
Method Development and Validation of the Simultaneous Determination of Omepra...
 
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
 
Analytical 2
Analytical 2Analytical 2
Analytical 2
 
Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacy
 Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacy Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacy
Shraddha roll no- 7 -m. pharm final presentation ---rbvrr college of pharmacy
 
Analytical method development and validation for the estimation of Nimesulide...
Analytical method development and validation for the estimation of Nimesulide...Analytical method development and validation for the estimation of Nimesulide...
Analytical method development and validation for the estimation of Nimesulide...
 
Multiple Method Development and Validation for Simultaneous Estimation of Chl...
Multiple Method Development and Validation for Simultaneous Estimation of Chl...Multiple Method Development and Validation for Simultaneous Estimation of Chl...
Multiple Method Development and Validation for Simultaneous Estimation of Chl...
 
Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...
Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...
Method Development and Validation of Clopidogrel Bisulphate by Reverse Phase-...
 
Ijpar 1 7
Ijpar 1 7Ijpar 1 7
Ijpar 1 7
 
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...
 
Diazo coupling for the determination of selexipag by visible spectrophotometry
Diazo coupling for the determination of selexipag by visible spectrophotometryDiazo coupling for the determination of selexipag by visible spectrophotometry
Diazo coupling for the determination of selexipag by visible spectrophotometry
 
Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...
Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...
Validated UV Method Development for the Simultaneous Estimation of Rabeprazol...
 
Stability indicating rp hplc method for the determination of candisartan
Stability indicating rp hplc method for the determination of candisartanStability indicating rp hplc method for the determination of candisartan
Stability indicating rp hplc method for the determination of candisartan
 
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
 
Y01062155162
Y01062155162Y01062155162
Y01062155162
 
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
Analytical Method Development and Validation of Dutasteride and Tamsulosin Hc...
 
Analytical method development and validation for the estimation of quinapril ...
Analytical method development and validation for the estimation of quinapril ...Analytical method development and validation for the estimation of quinapril ...
Analytical method development and validation for the estimation of quinapril ...
 

Andere mochten auch

Mainstreaming Open Educational Practice in a Research University: Prospects a...
Mainstreaming Open Educational Practice in a Research University: Prospects a...Mainstreaming Open Educational Practice in a Research University: Prospects a...
Mainstreaming Open Educational Practice in a Research University: Prospects a...Liz Masterman
 
Experiences in building a PaaS Platform - Java One SFO 2012
Experiences in building a PaaS Platform - Java One SFO 2012Experiences in building a PaaS Platform - Java One SFO 2012
Experiences in building a PaaS Platform - Java One SFO 2012Jagadish Prasath
 
Tineret ul sa tuul-ului
Tineret ul sa tuul-uluiTineret ul sa tuul-ului
Tineret ul sa tuul-uluicecisromania
 
February 2013 Rotary International Coordinator Communique
February 2013 Rotary International Coordinator CommuniqueFebruary 2013 Rotary International Coordinator Communique
February 2013 Rotary International Coordinator CommuniquePablo Ruiz Amo
 
Presentation1 updated11
Presentation1 updated11Presentation1 updated11
Presentation1 updated11Anas Edreesi
 
Presentation1 updated1
Presentation1 updated1Presentation1 updated1
Presentation1 updated1Anas Edreesi
 
#curatorgeneration: Brand Engagement with Tumblr, Pinterest and Instagram
#curatorgeneration: Brand Engagement with Tumblr, Pinterest and Instagram#curatorgeneration: Brand Engagement with Tumblr, Pinterest and Instagram
#curatorgeneration: Brand Engagement with Tumblr, Pinterest and InstagramHassan Mirza
 
Preproduction work
Preproduction workPreproduction work
Preproduction workecsmedia
 
GRADIUM MARKETING SUPPORT
GRADIUM MARKETING SUPPORTGRADIUM MARKETING SUPPORT
GRADIUM MARKETING SUPPORTJulio Matos
 
Research
ResearchResearch
Researchbeealex
 
Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...
Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...
Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...Michael Levine-Clark
 

Andere mochten auch (20)

Cambridgeshire Community Archives Network
Cambridgeshire Community Archives NetworkCambridgeshire Community Archives Network
Cambridgeshire Community Archives Network
 
Mainstreaming Open Educational Practice in a Research University: Prospects a...
Mainstreaming Open Educational Practice in a Research University: Prospects a...Mainstreaming Open Educational Practice in a Research University: Prospects a...
Mainstreaming Open Educational Practice in a Research University: Prospects a...
 
Experiences in building a PaaS Platform - Java One SFO 2012
Experiences in building a PaaS Platform - Java One SFO 2012Experiences in building a PaaS Platform - Java One SFO 2012
Experiences in building a PaaS Platform - Java One SFO 2012
 
Otter ppt
Otter pptOtter ppt
Otter ppt
 
Tineret ul sa tuul-ului
Tineret ul sa tuul-uluiTineret ul sa tuul-ului
Tineret ul sa tuul-ului
 
February 2013 Rotary International Coordinator Communique
February 2013 Rotary International Coordinator CommuniqueFebruary 2013 Rotary International Coordinator Communique
February 2013 Rotary International Coordinator Communique
 
Presentation1 updated11
Presentation1 updated11Presentation1 updated11
Presentation1 updated11
 
Presentation1 updated1
Presentation1 updated1Presentation1 updated1
Presentation1 updated1
 
#curatorgeneration: Brand Engagement with Tumblr, Pinterest and Instagram
#curatorgeneration: Brand Engagement with Tumblr, Pinterest and Instagram#curatorgeneration: Brand Engagement with Tumblr, Pinterest and Instagram
#curatorgeneration: Brand Engagement with Tumblr, Pinterest and Instagram
 
23.00.02
23.00.0223.00.02
23.00.02
 
Mobile and Accessibility - A Japanese Perspective
Mobile and Accessibility - A Japanese PerspectiveMobile and Accessibility - A Japanese Perspective
Mobile and Accessibility - A Japanese Perspective
 
Preproduction work
Preproduction workPreproduction work
Preproduction work
 
Gli zeppelin
Gli zeppelinGli zeppelin
Gli zeppelin
 
Sn i sentits EAT (2016)
Sn i sentits EAT (2016)Sn i sentits EAT (2016)
Sn i sentits EAT (2016)
 
Social media mistakes
Social media mistakesSocial media mistakes
Social media mistakes
 
GRADIUM MARKETING SUPPORT
GRADIUM MARKETING SUPPORTGRADIUM MARKETING SUPPORT
GRADIUM MARKETING SUPPORT
 
Research
ResearchResearch
Research
 
Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...
Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...
Demand-Driven Acquisitions for a Shared eBook Collection: The Colorado Allian...
 
Tugasan 2
Tugasan 2Tugasan 2
Tugasan 2
 
SMCMUC Social CRM
SMCMUC Social CRMSMCMUC Social CRM
SMCMUC Social CRM
 

Ähnlich wie Jopr29

Chlorthiazide analysis technique
Chlorthiazide analysis techniqueChlorthiazide analysis technique
Chlorthiazide analysis techniqueShraddha Kanvinde
 
020206 ps0108
020206 ps0108020206 ps0108
020206 ps0108Jing Zang
 
RP-HPLC method development & validation for estimation of Flecainide acetate ...
RP-HPLC method development & validation for estimation of Flecainide acetate ...RP-HPLC method development & validation for estimation of Flecainide acetate ...
RP-HPLC method development & validation for estimation of Flecainide acetate ...SriramNagarajan18
 
Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...SriramNagarajan18
 
020209 ps0067
020209 ps0067020209 ps0067
020209 ps0067Jing Zang
 
IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...
IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...
IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...iosrphr_editor
 
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLCSimultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLCpharmaindexing
 
Paracetamol_Paper Published_Aug 2015
Paracetamol_Paper Published_Aug 2015Paracetamol_Paper Published_Aug 2015
Paracetamol_Paper Published_Aug 2015Mohan Thippeswamy
 
Hplc zidovudine and lamivudine tablets
Hplc zidovudine and lamivudine tablets Hplc zidovudine and lamivudine tablets
Hplc zidovudine and lamivudine tablets SurbhiSharma196
 
RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...BRNSSPublicationHubI
 
A newly validated HPLC method development for simultaneous estimation of rito...
A newly validated HPLC method development for simultaneous estimation of rito...A newly validated HPLC method development for simultaneous estimation of rito...
A newly validated HPLC method development for simultaneous estimation of rito...SriramNagarajan19
 
Stability indicating method development and validation for the estimation of ...
Stability indicating method development and validation for the estimation of ...Stability indicating method development and validation for the estimation of ...
Stability indicating method development and validation for the estimation of ...SriramNagarajan18
 
A novel validated stability Indicating RP-HPLC Method Development for the est...
A novel validated stability Indicating RP-HPLC Method Development for the est...A novel validated stability Indicating RP-HPLC Method Development for the est...
A novel validated stability Indicating RP-HPLC Method Development for the est...Naveen Chennamaneni
 
Method Development and Validation on Etomidate injection by RP-HPLC
Method Development and Validation on Etomidate injection by RP-HPLCMethod Development and Validation on Etomidate injection by RP-HPLC
Method Development and Validation on Etomidate injection by RP-HPLCpharmaindexing
 
Differential spectrophotometric method for estimation and validation of Verap...
Differential spectrophotometric method for estimation and validation of Verap...Differential spectrophotometric method for estimation and validation of Verap...
Differential spectrophotometric method for estimation and validation of Verap...roshan telrandhe
 

Ähnlich wie Jopr29 (20)

Chlorthiazide analysis technique
Chlorthiazide analysis techniqueChlorthiazide analysis technique
Chlorthiazide analysis technique
 
020206 ps0108
020206 ps0108020206 ps0108
020206 ps0108
 
RP-HPLC method development & validation for estimation of Flecainide acetate ...
RP-HPLC method development & validation for estimation of Flecainide acetate ...RP-HPLC method development & validation for estimation of Flecainide acetate ...
RP-HPLC method development & validation for estimation of Flecainide acetate ...
 
Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...Stability indicating analytical method development and validation for estimat...
Stability indicating analytical method development and validation for estimat...
 
Issue1 Paper1
Issue1 Paper1Issue1 Paper1
Issue1 Paper1
 
020209 ps0067
020209 ps0067020209 ps0067
020209 ps0067
 
IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...
IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...
IOSR Journal of Pharmacy (IOSRPHR), www.iosrphr.org, call for paper, research...
 
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLCSimultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
 
Paracetamol_Paper Published_Aug 2015
Paracetamol_Paper Published_Aug 2015Paracetamol_Paper Published_Aug 2015
Paracetamol_Paper Published_Aug 2015
 
Hplc zidovudine and lamivudine tablets
Hplc zidovudine and lamivudine tablets Hplc zidovudine and lamivudine tablets
Hplc zidovudine and lamivudine tablets
 
RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...
 
Four drugs paper
Four drugs  paperFour drugs  paper
Four drugs paper
 
Four drugs paper
Four drugs  paperFour drugs  paper
Four drugs paper
 
A newly validated HPLC method development for simultaneous estimation of rito...
A newly validated HPLC method development for simultaneous estimation of rito...A newly validated HPLC method development for simultaneous estimation of rito...
A newly validated HPLC method development for simultaneous estimation of rito...
 
Stability indicating method development and validation for the estimation of ...
Stability indicating method development and validation for the estimation of ...Stability indicating method development and validation for the estimation of ...
Stability indicating method development and validation for the estimation of ...
 
A novel validated stability Indicating RP-HPLC Method Development for the est...
A novel validated stability Indicating RP-HPLC Method Development for the est...A novel validated stability Indicating RP-HPLC Method Development for the est...
A novel validated stability Indicating RP-HPLC Method Development for the est...
 
Method Development and Validation on Etomidate injection by RP-HPLC
Method Development and Validation on Etomidate injection by RP-HPLCMethod Development and Validation on Etomidate injection by RP-HPLC
Method Development and Validation on Etomidate injection by RP-HPLC
 
Differential spectrophotometric method for estimation and validation of Verap...
Differential spectrophotometric method for estimation and validation of Verap...Differential spectrophotometric method for estimation and validation of Verap...
Differential spectrophotometric method for estimation and validation of Verap...
 
Research
ResearchResearch
Research
 
Cetirizine and pseudoephedrine
Cetirizine and pseudoephedrineCetirizine and pseudoephedrine
Cetirizine and pseudoephedrine
 

Jopr29

  • 1. This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and education use, including for instruction at the authors institution and sharing with colleagues. Other uses, including reproduction and distribution, or selling or licensing copies, or posting to personal, institutional or third party websites are prohibited. In most cases authors are permitted to post their version of the article (e.g. in Word or Tex form) to their personal website or institutional repository. Authors requiring further information regarding Elsevier’s archiving and manuscript policies are encouraged to visit: http://www.elsevier.com/copyright
  • 2. Author's personal copy j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4 Available online at www.sciencedirect.com journal homepage: www.elsevier.com/locate/JOPR Original Article Simple RP-HPLC method for estimation of diazepam in tablet dosage form A. Sruthi, P. Tejaswi, N. Thanuja, D. Sudheer Kumar, P. Vivek Sagar* Department of Pharmaceutical Analysis, Care College of Pharmacy, Warangal, Andhra Pradesh, India article info abstract Article history: A simple reverse phase HPLC method was developed and validated for the determination Received 11 September 2012 of diazepam present in pharmaceutical dosage form. A Hypersil ODS C-18 column Accepted 4 November 2012 (250 Â 4.6 mm, packed with 5 microns) is used as stationary phase. An isocratic mode with mobile phase consisting of acetonitrile, methanol and 1% phosphate buffer (pH-3) in ratio Keywords: of 18:58:24 (v/v/v) at a flow rate of 1 ml/min and effluent was monitored at 232 nm. RP-HPLC Chromatogram showed a peak of DZP at retention time of 6.23 Æ 0.002 min. The linearity Diazepam range was found to be 2e20 mg/ml. The method was validated for linearity, accuracy, Validation precision, limit of detection, limit of quantitation, robustness and ruggedness. Recovery of Pharmaceutical dosage form DZP was found to be in the range of 99.4e100.3%. The limit of detection and limit of quantitation for estimation of DZP was found to be 0.898 mg/ml and 2.72 mg/ml, respectively. Proposed method was successfully applied for the quantitative determination of DZP in pharmaceutical dosage forms. Copyright ª 2012, JPR Solutions; Published by Reed Elsevier India Pvt. Ltd. All rights reserved. 1. Introduction expensive. The present study focused on minimizing these limitations and to develop a simple precise accurate and Diazepam (7-chloro-1, 3-dihydro-1-methyl-5-phenyl-2H-1, economic method for estimation of diazepam in tablet dosage 4-benzodiazepin-2-one) is a benzodiazepine (BZD) generally form. used as hypnotic, anxiolytic and muscle relaxant. Diazepam (DZP) is also routinely prescribed as the standard first-line treatment for acute convulsions and prolonged status epi- lepticus.1 Several methods for the analysis of BZDs have been reported.2 A number of chromatographic methods, such as thin-layer chromatography (TLC)3 gas chromatography4e6 and gas chromatographicemass spectrometry (GCeMS)7,8 have been used in the analysis of diazepam and other 1,4-benzo- diazopines. Several high-performance liquid chromato- graphic (HPLC) methods have also been reported for the determination of diazepam and other BZDs.9,10 However, all of these methods have limitations such as long run times and/or * Corresponding author. E-mail address: viveksagar.p111@gmail.com (P. Vivek Sagar). 0974-6943/$ e see front matter Copyright ª 2012, JPR Solutions; Published by Reed Elsevier India Pvt. Ltd. All rights reserved. http://dx.doi.org/10.1016/j.jopr.2012.11.029
  • 3. Author's personal copy j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4 141 2.4. Preparation of working standard solutions 2. Materials and methods Working standard solutions ranging from 0.5 to 50 mg/ml were 2.1. Chemicals and reagents prepared by appropriate dilutions of the stock with distilled water. An analytically pure sample of diazepam was procured as gift sample from Natco Pharma Ltd. (Hyderabad, India). 2.5. Preparation of sample solution HPLC grade methanol was procured from E. Merck (Hyder- abad). Liquid chromatographic grade water was obtained by Twenty tablets of diazepam hydrochloride were weighed and double distillation and purification through Milli-Q water ground into a fine powder. A quantity of powder equivalent to purification system. Potassium dihydrogen phosphate (AR 25 mg of diazepam was weighed and transferred into a 25 ml grade, purity 99.5%) was procured from Qualigens. Tablet volumetric flask and was dissolved in 0.1 N HCl. The volume formulations VALIUM (Nicholas Piramal India Ltd.) was was made up to the mark with the same. Above solution was procured from a local pharmacy with labeled amount 5 mg suitably diluted with distilled water. From this stock, appro- per tablet. priate dilution (10 mg/ml) was prepared. The solution thus prepared was filtered through 0.45 m membrane filter and the 2.2. Instrumentation & chromatographic conditions resulting filtrate was sonicated for 10 min. After setting the chromatographic conditions and stabilizing the instrument to The HPLC analysis was performed on CYBERLAB HPLC obtain a steady baseline, the sample solution was loaded in equipped with an LCP-100 reciprocating HPLC pump. A the 20 ml fixed e sample loop of the injection port. manually operating Rheodyne injector with 20 mL sample loop, a LC-UV 100 ultraviolet detector was used. Chromato- 2.6. Method development graphic analysis was performed on a Hypersil reversed phase C-18 column with 250 Â 4.6 mm i.d. and 5 mm particle size. Initial trial experiments were conducted, with a view to select The mobile phase consist of acetonitrile, methanol, 1% a suitable solvent system for the accurate estimation of the phosphate buffer (pH-3) in ratio of 18:58:24 (v/v/v) that was set drug and to achieve good retention time. The suitability of the at a flow rate of 1 ml/min. The mobile phase was degassed mobile phase decided on the basis of the sensitivity of the and filtered through 0.25 mm membrane filter before pumping assay, time required for the analysis, ease of preparation, and into HPLC system. The eluent was monitored by UV detection use of readily available cost effective solvents. These include at 232 nm. methanol-potassium dihydrogen phosphate, methanol- ammonium acetate, acetonitrile-potassium dihydrogen phos- 2.3. Stock solutions and standards phate, acetonitrile-ammonium acetate, methanol-water. The mobile phase consisting of acetonitrile, methanol, 1% phos- Stock solution of diazepam (1 mg/ml) was prepared by phate buffer (pH-3) in ratio of 18:58:24 (v/v/v) that was set at transferring 25 mg of drug in a 25 ml volumetric flask. The a flow rate of 1 ml/min was found to be optimum and further drug is dissolved in sufficient amount of 0.1 N HCl and optimized by adjusting pH 3e4 by adding orthophosphoric acid. finally the volume was made up to the mark with distilled The composition of acetonitrile, methanol, 1% phosphate water. buffer in ratio of 18:58:24 (v/v/v) with pH-3 gave the best results. Fig. 1 e Chromatogram of diazepam.
  • 4. Author's personal copy 142 j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4 Table 1 e Linearity of diazepam. Table 2 e Precision. S. No Concentration Peak area S. No Concentration Peak area (ppm) (ug/ml) 1 2 7569.8 1 6 21709.4 2 4 17892.9 2 6 21627.7 3 6 23612.2 3 6 21939.6 4 8 34517.2 4 6 21710.5 5 10 40051.3 5 6 21337.9 6 12 47631.9 6 6 21929.5 7 14 54925.1 Mean 21709.1 8 16 65942.9 % RSD 1.02 9 18 72965.0 10 20 80440.3 triplicate.11 20 ml of each of standard solutions were injected into the HPLC system to get the chromatograms. The retention 2.7. Solution stability time, average peak areas were recorded. Calibration curve was constructed by plotting average peak area against concentra- In order to demonstrate the stability of both standard and tion and regression equation was computed. The linearity sample solutions during analysis, both solutions were analyzed range was found to be 2e20 mg/ml. The results were shown in over a period of 96 h at an interval of 24 h at room temperature. Table 1. The results show that an excellent correlation exists The results show that for solutions, the retention time and peak between peak area and concentration of drug within the area of diazepam hydrochloride remained unchanged and no concentration range, regression graph is presented in Fig. 2. significant degradation within the indicated period, this indi- cates that both solutions were stable for 72 h. 3.2.2. Precision The precision of method was ascertained from the peak area response obtained by actual determination of six replicates of 3. Results and discussion a fixed amount of drug. The percent relative standard devia- tions were calculated for diazepam and presented in the Table 3.1. Analysis of formulation 2. The precision of the method was found to be 1.02. The sample solution was injected and a chromatogram was 3.2.3. Accuracy recorded. The injections were repeated six times and the peak Accuracy of developed method was confirmed by doing areas were recorded. The amount of drug present in the recovery study as per ICH norms. A known quantity of the pharmaceutical formulation was calculated using standard pure drug was added to the pre-analyzed sample formulation calibration curve (concentration in mg/ml was taken on X-axis (10 mg/ml) at three different concentration levels 80%, 100% and average peak area on Y-axis). Percentage of drug present and 120% by replicate analysis (n ¼ 3). From the recovery study in each tablet was found to be 100.2. A representative chro- it was clear that the method is very accurate for quantitative matogram has been given in Fig. 1. estimation of diazepam hydrochloride in tablet dosage form as all the statistical results were within the range of accep- 3.2. Validation of the assay method tance, 99.4e100.3%, which shows that there is no interference with excipients. Percentage recovery values were calculated 3.2.1. Linearity and the results were shown in Table 3. Different concentrations in the range of 0.5e50 mg/ml were prepared. Each of the levels of concentration was prepared in 3.2.4. Ruggedness Ruggedness is the degree of reproducibility of the results ob- tained under a variety of conditions. From stock solution, solutions containing 14 mg/ml of diazepam hydrochloride was prepared and analyzed by two different analysts using same operational and environmental conditions in different Table 3 e Accuracy. Amount of Amount of Average % drug added drug recovered recovery (ppm) (ppm) 8 7.592 99.4 10 9.98 99.8 12 12.096 100.3 Fig. 2 e Linearity of diazepam.
  • 5. Author's personal copy j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4 143 Table 4 e Ruggedness. Table 7 e System suitability parameters. Date % Recovery Drug RT Peak Peak USP plate USP area height count tailing Analyst-1 Day-1 100.2% Analyst-2 Day-2 99.8% Diazepam 6.2266 31432.2 2588 5238.42 1.1 % Deviation 0.4% accuracy and precision. The requirements for system suit- ability are usually developed after method development and Table 5 e Robustness. validation has been completed. The system suitability parameters like Theoretical plates (N), Resolution (R), Tailing S. No Wavelength 232 Wavelength 235 factor (T) were calculated and compared with the standard 1 52156.6 54973 values to ascertain whether the proposed RP-HPLC method for 2 52700.8 52955.4 the estimation of diazepam in pharmaceutical formulations 3 50662.6 52965.9 was validated or not. The results were shown in Table 7. 4 50905.7 54751.1 5 51418.4 54821.7 6 50911.8 52886.1 Mean 51459.32 53892.22 4. Conclusion % RSD 1.57 1.94 A convenient, rapid, accurate, precise and economical RP- HPLC method has been developed for estimation of diazepam experimental periods. Percentage recoveries of the replicates in bulk and tablet dosage form. The assay provides a linear were calculated. It is checked that the results are reproducible response across a wide range of concentrations and it utilizes under differences in, analysts. The results are shown in Table 4. a mobile phase which can be easily prepared and diluent is economic, readily available. The proposed method can be 3.2.5. Robustness used for the routine analysis of diazepam hydrochloride in The method was found to be robust, although small deliberate bulk preparations of the drug and, in pharmaceutical dosage changes in method conditions did have a negligible effect on forms without interference of excipients. the chromatographic behavior of the solute. The results indicate that changing the detector wavelength had no large effect on the chromatographic behavior of diazepam hydro- chloride. Even a small change of mobile phase composition Conflicts of interest (pH 3 Æ 0.2), did not cause a notable change in the peak area of All authors have none to declare. the used drug for this method. The results were presented in Tables 5 and 6. references 3.2.6. LOD & LOQ LOD and LOQ for diazepam were estimated by injecting a series of dilute solutions with known concentration. The 1. Crawley J, Smith S, Kirkham F, Muthinji P, Waruiru C, parameters LOD and LOQ were determined on the basis of Marsh K. Seizure activity and neurological sequelae in peak response and slope of the regression equation. The LOD Ugandan children who have survived an episode of cerebral and LOQ of the drug were found to be 0.898 mg/ml and 2.72 mg/ malaria. QJM. 1996;89:591. ml respectively. 2. Rouini Mohammad-Reza, Ardakani Yalda H, Moghaddam Kambiz A, Solatani F. An improved HPLC method for rapid quantitation of diazepam and its major 3.2.7. System suitability parameters metabolites in human plasma. Talanta. 2008;75:671. System suitability parameters can be defined as tests to 3. van der Merwe PJ, Steyn JM. Rapid and simple ensure that the method can generate results of acceptable chromatographic method for the determination of diazepam and its major metabolites in human plasma and urine. J Chromatogr. 1978;148:549. 4. Gjerde H, Dahlin E, Christophersen AS. Clinical impairment of Table 6 e Robustness. benzodiazepinesdrelation between benzodiazepine concentrations and impairment in apprehended drivers. S. No Mobile phase pH: 3.0 Mobile phase pH: 3.2 J Pharm Biomed Anal. 1992;10:317. 1 54247.2 52156.6 5. Fisher LE, Perch S, Bonfiglio MF, Geers SM. Simultaneous 2 53976.3 52700.8 determination of midazolam and flumazenil concentrations 3 53176.6 50662.6 in human plasma by gas chromatography. J Chromatogr 4 53315.8 50905.7 Biomed Appl. 1995;665:217. 5 53346.8 51418.4 6. Herraez-Hernandez R, Louter AJ, Van de Merbel NC, 6 53758.8 50911.8 Brinkman UA. Automated on-line dialysis for sample Mean 53636.92 51459.32 preparation for gas chromatography: determination of % RSD 0.669 1.43 benzodiazepines in human plasma. J Pharm Biomed Anal. 1996;14:1077.
  • 6. Author's personal copy 144 j o u r n a l o f p h a r m a c y r e s e a r c h 6 ( 2 0 1 3 ) 1 4 0 e1 4 4 7. Hold K, Crouch DJ, Rollins DE, et al. Quantitation of alprazolam performance liquid chromatography analysis. J Chromatogr B. and hydroxyalprazolam in human plasma by negative ion 2001;750:177. chemical ionization GC/MS. J Mass Spectrom. 1996;31:1033e1038. 10. Wilhelm M, Battista HJ, Obendorf D. HPLC with simultaneous 8. Borrey D, Meyer E, Lambert W, Van Calenbergh S, Van UV and reductive electrochemical detection at the hanging Peteghem C, De Leenheer AP. Enzymatic hydrolysis improves mercury drop electrode: a highly sensitive and selective tool the sensitivity of emit screening for urinary benzodiazepines. for the determination of benzodiazepines in forensic J Chromatogr A. 2001;910:105. samples. J Anal Toxicol. 2001;25:250. 9. Bolner, Tagliaro F, Lomeo A. Optimised determination of 11. Validation of Analytical Procedure: Methodology, ICH Harmonized clobazam in human plasma with extraction and high- Tripartite Guideline. 1996.