The document provides information about the HT-2/9600 series spa control, including:
- It describes the control's features like controlling pumps, lighting, and temperature.
- It explains how to program settings for filtration cycles, economy mode, and other functions from the spaside control panel.
- It provides instructions for operating the control panel keys to control equipment and set temperatures.
- It describes alarms that will activate for issues like high temperature, pressure switch problems, and freeze protection.
3. HT-2 / 9600 Series Control Contents
Spa Control • Description
• Features
• HT-2 Spaside Control
Connection • Spaside to System Circuit Board
• Spaside to external Receptacle
Instructions • Pump 1 Key
• Pump 2 Key
• Light Key
• Temperature Set Keys
• Heater Auto Start
• Temperature Display
• Filter Cycles (Start Time)
• Filter Cycles (Duration)
• Economy Mode (Start Time)
• Economy Mode (Duration)
Alarms
• Freeze Protection
• High Temperature
• Pressure Switch
• Temperature Sensor
• High-Limit Temperature Sensor
• Economy Mode
• Smart Winter Mode
• Power Failure
Programming • Low Level Programming
Internal Wiring • Wiring Diagram
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
4. HT-2 / 9600 Series Control Spa Control
Description The Ultimate Series Control is a perfect fit for larger spas. It can
control two single or dual speed pumps, an air blower, an electric
heater, ozonator, circulation pump, fiber optics to meet the demands of
today’s market. The 9600 and it’s HT-2 spaside control keypad allow
the users to control all of the functions and programming from spa
side.
Energy The HT-2 / 9600 Series Control can be configured for maximum
Conservation energy efficiency. It can control electric, gas or solar heat. The filtration
cycle can be configured to run at non-peek hours of the day. The
economy mode can be set to come on during peek hours, which will
keep the spa 20°F below the Set Point.
Features • Automatic time-out on all outputs
• LCD display
• LCD temperature display
• Spaside control High-Limit reset
• Sensor failure detection
• Programmable filtration cycle
• High-Limit protection
• Pressure switch failure detection
• Current limiting option
• Freeze protection
• Temperature measurement within +1°F
HT-2 Spaside • Temperature set point
Control • Temperature display in °C or °F
• Pump 1 control
• Pump 2 control
• Air Blower control (3-speeds)
• Light control (up to 3 intensities)
• Fiber Optic control
• High-Limit temperature reset
• Programmable filtration cycle
• Smart Winter Mode
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
5. HT-2 / 9600 Series Installation Spaside Control
Connection to The HT-2 Spaside control must
Control Box be securely connected to the
systems circuit board or to the
external receptacle. Connect the
spaside control as shown.
Pump 1 Key The Pump 1 Key is used to turn
the pump on and to select high
and low speeds (dual speed
pump).
Press the Pump 1 Key to turn the
pump on in low speed. A second
press will change the pump to
high speed. A third press will turn
the pump off.
The Pump 1 Icon will appear
while the pump is running. The
pump will shut off automatically
after 20 minutes unless done so
manually.
Pump 2 Key The Pump 2 Key is used to turn
the pump on and to select high
and low speeds (dual speed
pump).
Press the Pump 2 Key to turn the
pump on in low speed. A second
press will change the pump to
high speed. A third press will turn
the pump off.
The Pump Icon will appear while
the pump is running. The pump
will shut off automatically after 20
minutes unless done so
manually.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
6. HT-2 / 9600 Series Instructions Spaside Control
Blower Key The Blower Key is used to turn
the blower on and off or to select
between high, medium, low
speed and off (three speed).
Press the Blower Key to turn the
blower onto high speed. A
second press will turn the blower
off or change the speed to
medium (three speed). A third
press will turn the blower onto
low speed. A fourth press will
turn the blower off.
The Blower Icon will appear
when the blower is on. The
blower will shut off automatically
after 20 minutes unless done so
manually.
Light Key The Light Key is used to turn the
(Without Fiber Light on and off or to select
Optics) between high, medium and low
intensities and off.
Press the Light Key to turn the
light on. A second press will turn
the light off or change it to
medium intensity. A third press
will turn the light to low intensity
and a fourth press will turn the
light off.
The Light Icon will appear when
the light is on. The light will shut
off automatically after 2 hours
unless done so manually.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
7. HT-2 / 9600 Series Instructions Spaside Control
Light Key The first press of the Light Key
(With Fiber Optics) will show “L1” on the display.
Use the Up Arrow Key to set the
light intensity to high, medium,
low then to Off.
Press the Light Key a second
time, “F1” will be displayed. Use
the Up Arrow Key to select fiber
optic light and color wheel on,
fiber optic light only and both off.
The Light Icon will appear when
the light is on. The light will shut
off automatically after 2 hours
unless done so manually.
Program Key The Program Key is used to
program the filtration cycle,
Economy Mode, Temperature
Unit and Spaside Lock.
Press the Program Key, the
Program Icon will appear in the
upper window and CL will appear
in the lower window. This is the
parameter used to set the time.
Pressing the Blower Key will
move you through each
parameter. To enter a parameter
and modify it, press the Light
Key. Use the Up & Down Arrow
Keys to adjust the value. Press
the Program Key to exit this
mode.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
8. HT-2 / 9600 Series Instructions Spaside Control
Program Key Time of Day:
“CL” will appear in the LCD window.
Set any time from 00:00 to 23:59.
Filtration Cycle Start Time:
“FIon” will appear in the LCD window.
Set time from 00:00 to 11:59.
Filtration Duration:
“ FIdu” will appear in the LCD window.
Set duration from Off (no filtration) to
12:00 (continuous filtration).
Economy Start Time:
“ECon” will appear in the LCD window.
Set any time from 00:00 to 23:59.
Economy Duration:
“ECdu” will appear in the LCD window.
Set any hour from Off to 24:00 (always
on).
Temperature in F° or C°:
“Tu” will appear in the LCD window.
Set either F or C.
Spa-Side Lock:
“Loc” will appear in the LCD window.
Set to either On or Off.
While the Spa-Side is locked you will
not be able to change the programming,
adjust the Set Point temperature or
change the Economy Mode. This mode
is a helpful when small children are
using the spa.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
9. HT-2 / 9600 Series Instructions Spaside Control
Economy Key This key is used to switch
between Economy and Normal
modes.
The Economy Mode will maintain
the water temperature at a point
20°F below the set temperature.
This mode is recommended for
occasional use when a minimal
heating time is required.
The Normal Mode will
automatically maintain the water
temperature at the desired set
point.
This mode is recommended for
users that desire the spa to be
available 24 hours a day.
Up & Down Arrow The Up & Down Arrow Keys are
Keys used to set the spa water
temperature, which can be
adjusted from 59°F to 104°F in
1°F increments.
Keeping pressure on the key will
increase (or decrease) the
current temperature setting.
The Set Point Icon will appear
telling the user that the
temperature displayed is the
desired and not the actual
temperature.
If when the temperature is set to 104°F
the user keeps the Up Arrow Key
depressed for 5 seconds, the unit will
go into “over temperature” mode. This
allows the Set Point to be raised up to
107°F.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
10. HT-2 / 9600 Series Instructions Spaside Control
Heater Auto Start When the water temperature is
1°F lower than the Set Point, the
heater and pump will be turned
on until the water temperature
reaches the Set Point plus 1°F.
The Heater Icon will appear while
the heater is on.
Temperature The 3-digit LCD display shows
Display the water temperature reading.
The reading will be refreshed
every second.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
11. HT-2 / 9600 Series Instructions Spaside Control (Alarms)
Freeze Protection If the spa water temperature falls to 38°F at the high limit sensor, the
system will activate the pump (low speed for dual speed pump) and
heater for 2 minutes.
High Temperature If the water temperature exceeds
112°F at the Temperature
sensor, the heater and all
functions will be deactivated and
“3- flashing dots” will appear
below the temperature display
and an error LED will illuminate
on the systems printed circuit
board. If the water temperature
exceeds 119°F at the Hi-Limit
sensor the heater will be turned
off until the water has cooled to
110°F. “3-flashing dots” will
appear below the temperature
display and an error LED will
illuminate on the systems printed
circuit board.
Pressure Switch To prevent damage to your
heater due to “dry fire”, there is a
flow or pressure switch mounted
to the heater. The system
constantly checks the switch. If
the pump used to circulate the
water through the heater is not
operating and the pressure
switch is closed, “3-flashing
dots” will appear below the
temperature display.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
12. HT-2 / 9600 Series Instructions Spaside Control (Alarms)
Pressure Switch If the pump is operating and the
flow or pressure switch is open,
“3-flashing dots” will appear
below the temperature display
and the heater will not engage.
Note: A dirty filter limiting the
water flow or low spa water level
can cause this message to
appear.
When the pump is turned on,
there is a 7-second delay before
the heater system will start to
auto check the pressure switch.
Temperature If the system detects a problem
Sensor with the water temperature
sensor, 32°F will appear and
remain on the Spaside display.
The system will engage the
heater as a form of freeze
protection. If, in 1-hour, the
system has not sensed a rise in
the temperature, “3-flashing
dots” will also appear below the
temperature display.
Freeze Protection If the spa water temperature
drops below 49°F, the pump and
heater will be turned for a period
of 2 minutes or until the spa
water reaches 50°F. The Filter
Icon will appear during this
mode.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
13. HT-2 / 9600 Series Instructions Spaside Control (Alarms)
Smart Winter Hydro-Quip solid-state systems are equipped with a sensor that
Mode measures the temperature in the plumbing of the spa. If the system
detects conditions below 59°F, the system will automatically activate
the Smart Winter Mode for a period of 24 hours. In this mode, if a
pump has not been powered in the last 2 hours, the system will turn it
on for one minute to prevent freezing. The Filter Mode light Icon will
flash while the pump is running in this mode.
Power Failure Upon first powering the system or if a power outage occurs, the
display will flash until a key is pressed. This feature also lets the user
know there has been a power failure. The onboard clock may need to
be reprogrammed. Normally the onboard clock will keep the correct
time for at least 48 hours after a power outage. A power outage will
not affect the programming.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
14. HT-2 / 9600 Series Programming Low Level Programming
It is possible to change the parameters of the Equipment System by positioning specific jumpers
located on the system board.
To enter the Low Level Programming press and hold the Program Key for 20 seconds until the
first programming parameter appears, which is P1 for Pump 1. Use Up and Down Arrow Keys to
increase or decrease the programming value. Press the Light Key to continue through each
programming parameter using the Up and Down Arrow Keys to set the value. You must
continue through all parameters to exit this mode.
P1 (Pump 1) Value 1 – Single Speed Value 2 – Dual Speed
P2 (Pump 1) Value 0 – No Second Pump Value 1 – Single Speed Value 2 – Dual Speed
bL (Blower) Value 0 – No Air Blower Value 1 – Single Speed / 20 minute timeout
Value 2 – Two Speed / 20 min. timeout Value 3 – Three Speed / 20 min. timeout
Value 4 – Single Speed / 2-hour timeout Value 5 – Single Speed / 6-hour timeout
Value 6 – Single Speed / 12-hour timeout
L1 (Light) Value 0 – No Light Value 1 – 12VAC Single Intensity
Value 2 – 12VAC Three Intensities Value 3 – 120VAC Light
O3 (Ozone) Value 0 – No Ozone Value 1 – On during filtration only Value 2 – Always On
AU (Fiber Optic) Value 0 – No Fiber Optics Value 1 – Fiber Optics Installed
Ti (Time) Value 12 – Standard Clock Value 24 – 24-hour (military clock)
Cu (Current) Value 0 – No Heat with High Speed Pump or Blower (120VAC)
Value 1 – No Current Restriction (240VAC)
Cp (Circ. Pump) Value 0 – No Circulation Pump Value 1 – Regulated with Spa Temperature
Value 2 – Always On
r (Sensor Calibration) Value can be adjusted from 46.0 to 55.9 (this number is marked on the temperature
sensor and is programmed at the factory).
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
15. HT-2 / 9600 Series Control Wiring Diagram