The Future of Battery Technologies – Part III
Risks/Safety Factors for Lithium Batteries




Dr. Annika Ahlberg Tidblad




www.intertek.com                           1
This white paper is the third in our series on “The Future of Battery Technologies,” and provides an overview on
the risks and safety factors associated with lithium batteries– common causes of external and internal battery
faults, common issues to consider for primary and rechargeable batteries, and more. The white paper was
authored by Dr Annika Ahlberg Tidblad, Intertek’s resident expert in battery testing. Her background is in research
at KTH, the Swedish Royal Institute of Technology, with PhDs in applied electrochemistry and corrosion science,
along with ten years of experience in battery technology.



The Future of Battery Technologies – Part III – Risks/Safety
Factors for Lithium Batteries

One of the lithium battery's major strengths is its high energy density, but that is also why the
risks of lithium-based chemistry are greater than in other battery systems, should anything go
wrong. Although the risks are directly linked to the specific cell chemistry, cell size and the
number of cells in the battery, there are certain common factors. Lithium batteries contain
inflammable material in the form of organic electrolytes that have a low flash point and
polymers that can maintain a fire and increase the risk of spreading to surrounding areas. The
anode in primary lithium batteries consists of metallic lithium that melts at 180° and it reacts
                                                                                   C,
violently with water and air if the cell breaks or vents. The cells also contain several
compounds that are toxic in themselves and which form harmful combustion products in the
case of fire.

                     One should always try to avoid exposing batteries to heat. This is partly
                     because the cell chemistry may become unstable if the temperature is too
                     high, which can lead to venting, and in the worst case scenario, to
                     explosion and fire. Partly because heat accelerates the normal chemical
                     processes taking place in the battery cell, and thereby such reactions and
                     processes that lead to aging and loss of capacity, i.e. decomposition of
                     both electrode and electrolyte material. Heat can either be generated by
                     the cell itself or come from an external source. This is especially
                     problematic if a multi-cell battery is exposed to uneven thermal conditions,
                     as the cells will age at different rates, which may lead to problems in cell
balancing. Cell balancing means that battery cells that must interact in one and the same stack
are chosen in such a way that the cell capacity has as little spread as possible. A battery stack
is never stronger than the weakest cell.

Low temperatures can also pose a problem. Primary batteries generally only lose their function
when it becomes too cold, which can be serious enough. Rechargeable batteries often have
limited chargeability at low temperatures, and should not be charged if the ambient
temperature is lower than the lowest recommended charge temperature, as it may lead to
formation of metallic lithium which is precipitated as islands on the anode, so-called lithium
plating, and forms dendrites that can cause interior short circuits in the cell.


www.intertek.com                                                                                                 1
Common External Causes of Battery Faults

Some of the most common causes of battery faults originating from the user or application
include:

   1.   External short circuit of the battery
   2.   Too high discharge or charge current
   3.   Pole reversal, i.e. discharge of a cell below 0V
   4.   Charging primary batteries
   5.   Incorrect or insufficient charge control of chargable batteries

All five of these conditions generate heat to a varying extent in the battery cell, which leads to
increased aging or breakdown of the cell. As these risks are caused by external factors, it is
possible to prevent and avoid them.

External short circuit

When battery poles are short circuited, the high short circuit current leads to generation of a lot
of heat in the cell. The most efficient way of preventing this from happening is to employ smart
battery design that ensures that the + and - poles are physically isolated from each other, by
countersinking them into the battery casing and designing them in such a way that it is not
possible to connect the battery incorrectly. In certain cases, it may be necessary to integrate
further forms of protection in the form of a fuse, or a PTC (Positive Temperature Coefficient)
component, which breaks the electrical circuit if the current or the temperature begins to run
away. Certain cell manufacturers integrate PTCs in their cells.

It is also important to be aware of the risk of a short circuit when transporting individual cells or
batteries. The rules that exist for packaging lithium cells and batteries, with or without
equipment, are intended to prevent accidents from accidental short circuits.

Too high discharge or charge current

If the current is too high, the mass transport of the reactants for the
main reactions is limiting, and the charge volume applied is partially
consumed by other reactions in the cell, such as gassing and
decomposition, which lead to increases in temperature. If the
temperature increase is too high, it leads to further side reactions,
which in turn generate even more heat. This increases the risk of
venting and, in the worst-case scenario, uncontrolled cell reactions
and thermal runaway.




www.intertek.com                                                                                  2
When charging secondary cells, it is important not to exceed the recommended maximum
charge current. If the charge current is too high, there is a risk of the lithium ions not managing
to diffuse into the anode structure during charge, and instead being precipitated as lithium
metal on the anode surface, which results in loss of capacity but also increases the risk of
internal short circuits during subsequent use.

Apart from current limiters, it is important that there is a low voltage protection to prevent any
cell discharging below the lowest recommended voltage limit of the cell. In rechargeable
batteries, the low voltage protection prevents the anode's base metal, usually copper, from
dissolving and contaminating the cell. Li-ion cells that are heavily discharged risk both
irreversible loss of capacity and increased self-discharge in subsequent use. Rechargeable
batteries also need to be fitted with an over-voltage protection to prevent early aging, lithium
plating on the anode, because cathodes that consist of metal oxides form unstable phases and
lose oxygen to the surrounding area. Depending on the application and the complexity of the
battery, it is not always sufficient with over-voltage and low voltage protection at the stack
level, and control may have to be implemented on an individual cell level within the battery
stack.

Pole reversal

                          Pole reversal can take place in battery stacks that consist of multiple
                          cells connected in series. It is important to make sure that the cells in
                          a multi-cell battery stack are well matched to begin with, and they are
                          exposed to mainly the same loads and other conditions, so that the
                          capacity continues to be evenly distributed. Otherwise, in the worst
                          case scenario, the weakest cell could risk being heavily discharged
                          and forced to reverse its poles, which means that the cell would be
                          charged by the other cells, which are still being discharged. Multi-cell
                          battery stacks usually have a cell-balancing function that distributes
the current between the cells in a suitable manner. If the battery stack is fitted with low voltage
protection, this may help to prevent pole reversal.

Charging primary batteries

Primary lithium batteries are not constructed to be charged. If this takes place, gas is formed
within the cell, causing its internal pressure to rise. This may result in venting, or most
seriously, in explosion. Primary lithium cells connected in parallel, and thereby exposed to a
potential source of charging, should be protected by diodes.

Incorrect or insufficient charge control of rechargeable batteries

Charging is the single most risky element in the battery cycle, as energy is permitted to flow
into the system from an external source. It is extremely important to comply with the charge


www.intertek.com                                                                                  3
recommendations of the cell and battery manufacturers, both with respect to current limitation,
voltage limitation and temperature, in order to ensure a long and safe battery life. The risks
involved in too high charge current, exceeding the voltage limits, and too high and low
temperatures, have been discussed above.

Internal Causes of Battery Failure

In addition to external fault sources, there are risks that may be difficult to predict or prevent,
and which are caused by unsuitable cell design, manufacturing faults or ageing mechanisms
within the battery cell, such as:

   1. Weak or faulty seals that can cause leakage or failure
   2. Pollutants that can lead to gas-developing secondary reactions, resulting in aging or
      venting due to overpressure in the cell
   3. Internal short circuits caused by formation of dendrites on the electrodes, metal particles
      or faulty insulation of conductors, etc.

Primary lithium batteries

Primary lithium batteries have a higher energy density than the rechargeable Li-ion and Li-
polymer cells. Small primary cells, e.g. coin cells, often lack the integrated safety components
at cell level. Slightly larger cylinder batteries and prismatic cells often have so-called safety
valves, which is a form of fuse, or PTC.

The greatest safety risks are involved when a battery consists of several cells. In such cases,
the cells should be soldered together in a battery stack to lower the risk of the user mixing
different types of cell, and cell chemistries, when changing batteries. Even if the battery cells
have integrated overheating protection, it is recommended that the battery is fitted with an
external temperature limitation protector. The electrical protection must also include protection
against charging, short circuit and a bypass connection protection that prevents pole reversal
of an individual cell in a series, or a combination of serial and parallel connected cells.

In certain cases, a battery must be fully discharged before a used battery can be disposed of
safely as waste. If required, this takes place using a resistive load that gives a very low current
flow.

Rechargeable lithium ion batteries

Most of us have seen and remember the scenes of burning laptops
on the Internet, TV and in newspapers between 2006 and 2009.
Studies of failures in the field showed that these were usually
caused by an internal short circuit. The short circuit leads to the



www.intertek.com                                                                                      4
cell's energy being discharged through a very limited volume, which leads to a rapid local
temperature increase, reaching up to > 200° in sec onds. The heat induces the electrodes
                                              C
and electrolyte to begin to decompose, and these reactions add further heat, tipping the cell
into so-called thermal runaway in which the cell temperature and pressure increase
exponentially over time. The overpressure leads to the cell venting, which liberates electrolyte
aerosol in the surrounding area, and can easily ignite. In extreme cases, the cell splits or
explodes unless the overpressure can be ventilated out sufficiently quickly. Depending on the
construction of the cell and the internal positioning of the cells in a battery pack, the ignited
electrolyte from one cell may heat up the adjacent cells and causes the cascade effect.

Most Li-ion batteries on the market today indicate 60° as their upper usage temperature. The
                                                         C
majority of batteries currently on the market have graphite anodes. Graphite is not stable and
can react chemically with the electrolyte in the cell. During manufacture and formation of the
cell, a passive layer is formed on the anode surface, the SEI (Solid Electrolyte Interface) layer,
which prevents continued reaction between the electrode and the electrolyte. As early as 90-
120° the layer can begin to break down, allowing exothermal gas evolving reactions to
     C,
begin. If a sufficiently large area of the SEI layer breaks down, the cell may enter thermal
runaway.

Not all cells that develop an internal short circuit suffer thermal runaway. Factors that influence
this include:

   •   The size and location of the short circuit
   •   The size and design of the cell
   •   The active material in the cell; cobalt oxide is, e.g. more reactive than manganese
       dioxide and iron phosphate
   •   Thermal properties of the various materials in the cells and the cells' abilities to
       disseminate heat
   •   The cell’s state of charge, its age and history

Internal short circuits caused by production factors may occur in all types of Li-ion cells and it
is unlikely that it will be possible to completely eliminate this type of fault. There are various
types of integrated protection at cell level that attempt to prevent and counteract risks. Figure 1
shows a cut-through of a cylinder cell. At the top of the cell there are 2 mechanical protectors
in the form of a CID (current interrupt device) that triggers at a pressure of around 10 bar, and
a safety valve. Both of these are irreversible, and the cell no longer works if either of these
protectors is triggered. In addition, there is usually a PTC that throttles the current at
temperatures over 125° This PTC function is rever sible and conduction restarts when the
                           C.
temperature falls. The separator between the anode and the cathode consists of 3 layers of
polymer and is usually of the "shut-down" type, which means that when the cell temperature
gets too high, around 165° the separator melts an d the pores close. The consequence is
                              C,
that the electric circuit is broken as the ion conduction in the cell ceases to function. This effect
is irreversible. A number of additives have also been added to the electrolyte in the form of


www.intertek.com                                                                                  5
flame retardants or inhibitors and redox shuttles. The role of the redox shuttle is to manage
and consume any overcharge effect so that the cell voltage does not get too high. The cell
container is also a part of the total protection which secures the cell's integrity against its
surroundings.

The increasingly more common "pouch" cells, i.e. cells with a soft coating that consists of a
polymer-coasted metal foil, lack many of the mechanical protection components that are found
in cylindrical and prismatic cells with steel or aluminium casing. Pouch cells have no integral
CID, PTC or safety valve, but are completely dependent on external protection circuits. In the
case of a strong overpressure, the cell's welded seams split, generally in vicinity to the pole
connectors where the weld is the weakest. Nor are pouch cells as resistant to impact or
puncturing as cells with metal casing.




        Figure 1 Cut-through of a Li-Ion cylinder cell




   Intertek’s expertise in battery testing & energy storage services ensures products meet performance,
 reliability and safety criteria. Intertek has expanded global energy storage testing facilities and advisory
 services. Throughout design, manufacturing & system deployment cycles, Intertek provides evaluations
for performance, electrical safety, interoperability, fit for use, component selection and more. Please visit
 our website at www.intertek.com/energy-storage, contact icenter@intertek.com or call your regional lab:

                                  Europe: +46 8 750 00 00
                                  North America: +1 800 967-5352
                                  Asia Pacific: +86 21 6127-8200



www.intertek.com                                                                                        6

More Related Content

Viewers also liked

Novita' collna stupore
Novita' collna stuporeNovita' collna stupore
Novita' collna stuporeSulMonte
 
Challenge Ecomagination Blog 2011 GE
Challenge Ecomagination Blog 2011 GEChallenge Ecomagination Blog 2011 GE
Challenge Ecomagination Blog 2011 GEptharsocastro
 
Italia Deel 2
Italia Deel 2Italia Deel 2
Italia Deel 2Nancy Poh
 
Formulario_Visas_India_Documentacion_www.viajesver.com
Formulario_Visas_India_Documentacion_www.viajesver.comFormulario_Visas_India_Documentacion_www.viajesver.com
Formulario_Visas_India_Documentacion_www.viajesver.comviajesver
 
Unab1 Hist Componentes
Unab1 Hist ComponentesUnab1 Hist Componentes
Unab1 Hist ComponentesPaola Valencia
 
Spira plan overview presentation
Spira plan overview presentationSpira plan overview presentation
Spira plan overview presentationTrabalistra Bagaz
 
Leesman data presentation sml
Leesman data presentation smlLeesman data presentation sml
Leesman data presentation smltimoldman
 
British Council - International Career Day 2013 Milan
British Council - International Career Day 2013 MilanBritish Council - International Career Day 2013 Milan
British Council - International Career Day 2013 MilanJobadvisor
 
China Digital Trends, Year of the Rabbit Report - Zaheer Nooruddin
China Digital Trends, Year of the Rabbit Report - Zaheer NooruddinChina Digital Trends, Year of the Rabbit Report - Zaheer Nooruddin
China Digital Trends, Year of the Rabbit Report - Zaheer NooruddinZaheer Nooruddin
 
Uncommon Approaches to Common Spaces
Uncommon Approaches to Common SpacesUncommon Approaches to Common Spaces
Uncommon Approaches to Common SpacesMike Whaling
 
Measuring user journeys #4PsEDGE
Measuring user journeys #4PsEDGEMeasuring user journeys #4PsEDGE
Measuring user journeys #4PsEDGE4Ps Marketing
 
L2 cs110 jcu-sindonirev04092011
L2 cs110 jcu-sindonirev04092011L2 cs110 jcu-sindonirev04092011
L2 cs110 jcu-sindonirev04092011Giuseppe Sindoni
 
DFAIT Usability Final 6 Apr08
DFAIT Usability Final 6 Apr08DFAIT Usability Final 6 Apr08
DFAIT Usability Final 6 Apr08Barry Nesbitt
 

Viewers also liked (20)

Novita' collna stupore
Novita' collna stuporeNovita' collna stupore
Novita' collna stupore
 
Challenge Ecomagination Blog 2011 GE
Challenge Ecomagination Blog 2011 GEChallenge Ecomagination Blog 2011 GE
Challenge Ecomagination Blog 2011 GE
 
Italia Deel 2
Italia Deel 2Italia Deel 2
Italia Deel 2
 
A voltaao mundo
A voltaao mundoA voltaao mundo
A voltaao mundo
 
Emeco navy chair
Emeco navy chairEmeco navy chair
Emeco navy chair
 
Formulario_Visas_India_Documentacion_www.viajesver.com
Formulario_Visas_India_Documentacion_www.viajesver.comFormulario_Visas_India_Documentacion_www.viajesver.com
Formulario_Visas_India_Documentacion_www.viajesver.com
 
Italy, Beyond the Obvious
Italy, Beyond the ObviousItaly, Beyond the Obvious
Italy, Beyond the Obvious
 
Unab1 Hist Componentes
Unab1 Hist ComponentesUnab1 Hist Componentes
Unab1 Hist Componentes
 
Spira plan overview presentation
Spira plan overview presentationSpira plan overview presentation
Spira plan overview presentation
 
Leesman data presentation sml
Leesman data presentation smlLeesman data presentation sml
Leesman data presentation sml
 
Navy chair powerpoint
Navy chair powerpointNavy chair powerpoint
Navy chair powerpoint
 
ECO-TRIO DeNOx Plus Brochure
ECO-TRIO DeNOx Plus BrochureECO-TRIO DeNOx Plus Brochure
ECO-TRIO DeNOx Plus Brochure
 
British Council - International Career Day 2013 Milan
British Council - International Career Day 2013 MilanBritish Council - International Career Day 2013 Milan
British Council - International Career Day 2013 Milan
 
China Digital Trends, Year of the Rabbit Report - Zaheer Nooruddin
China Digital Trends, Year of the Rabbit Report - Zaheer NooruddinChina Digital Trends, Year of the Rabbit Report - Zaheer Nooruddin
China Digital Trends, Year of the Rabbit Report - Zaheer Nooruddin
 
Uncommon Approaches to Common Spaces
Uncommon Approaches to Common SpacesUncommon Approaches to Common Spaces
Uncommon Approaches to Common Spaces
 
Measuring user journeys #4PsEDGE
Measuring user journeys #4PsEDGEMeasuring user journeys #4PsEDGE
Measuring user journeys #4PsEDGE
 
L2 cs110 jcu-sindonirev04092011
L2 cs110 jcu-sindonirev04092011L2 cs110 jcu-sindonirev04092011
L2 cs110 jcu-sindonirev04092011
 
DFAIT Usability Final 6 Apr08
DFAIT Usability Final 6 Apr08DFAIT Usability Final 6 Apr08
DFAIT Usability Final 6 Apr08
 
Whitepaper-Custos
Whitepaper-CustosWhitepaper-Custos
Whitepaper-Custos
 
Sant andreu
Sant andreuSant andreu
Sant andreu
 

Similar to Battery white-paper-part-iii

Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...
Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...
Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...Lewis Larsen
 
Lead acid batteries life and death
Lead acid batteries life and deathLead acid batteries life and death
Lead acid batteries life and deathImran Shahnawaz
 
Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...
Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...
Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...Lewis Larsen
 
Battery Testing 101 by Megger and Transcat
Battery Testing 101 by Megger and TranscatBattery Testing 101 by Megger and Transcat
Battery Testing 101 by Megger and TranscatTranscat
 
The COST of Battery Maintenance_3.ppt
The COST of Battery Maintenance_3.pptThe COST of Battery Maintenance_3.ppt
The COST of Battery Maintenance_3.pptDileepaDaulagala
 
Degradation Curve effects and control technology.pptx
Degradation Curve effects and control technology.pptxDegradation Curve effects and control technology.pptx
Degradation Curve effects and control technology.pptxsheikhmuhammadawais7
 
P.p.t on types of electric cells
P.p.t on types of electric cellsP.p.t on types of electric cells
P.p.t on types of electric cellsPiyush Singh
 
Wet & dry batteries
Wet & dry batteriesWet & dry batteries
Wet & dry batteriesmunibz04
 
Battery (electricity)
Battery (electricity)Battery (electricity)
Battery (electricity)vishal gupta
 
Rechargeable Sodium-ion Battery - The Future of Battery Development
Rechargeable Sodium-ion Battery - The Future of Battery DevelopmentRechargeable Sodium-ion Battery - The Future of Battery Development
Rechargeable Sodium-ion Battery - The Future of Battery DevelopmentDESH D YADAV
 
Lecture 2 construction of lead acid battery 2
Lecture 2 construction of lead acid battery   2Lecture 2 construction of lead acid battery   2
Lecture 2 construction of lead acid battery 2manfredhaule
 
Presentation on electronic battery
Presentation on electronic batteryPresentation on electronic battery
Presentation on electronic batteryNaman Nandurkar
 
Li-Ion Batteries PPT.pdf
Li-Ion Batteries PPT.pdfLi-Ion Batteries PPT.pdf
Li-Ion Batteries PPT.pdfkingkymera9957
 
Smart Battery Management System for Lithium Ion Battery
Smart Battery Management System for Lithium Ion BatterySmart Battery Management System for Lithium Ion Battery
Smart Battery Management System for Lithium Ion BatteryIRJET Journal
 
Next generation batteries
Next generation batteries Next generation batteries
Next generation batteries awais awan
 
Basic cells and batteries
Basic cells and batteriesBasic cells and batteries
Basic cells and batteriesdesmondprince
 
A Study of the Factors that Affect Lithium Ion Battery Degradation
A Study of the Factors that Affect Lithium Ion Battery DegradationA Study of the Factors that Affect Lithium Ion Battery Degradation
A Study of the Factors that Affect Lithium Ion Battery DegradationPower System Operation
 

Similar to Battery white-paper-part-iii (20)

BATTERY.ppt
BATTERY.pptBATTERY.ppt
BATTERY.ppt
 
Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...
Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...
Lattice Energy LLC- Field Failures and LENRs in Lithium-based Batteries-Jan 2...
 
Lead acid batteries life and death
Lead acid batteries life and deathLead acid batteries life and death
Lead acid batteries life and death
 
Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...
Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...
Lattice Energy LLC-Why has Tesla Model S had more thermal runaways than Nissa...
 
Battery Testing 101 by Megger and Transcat
Battery Testing 101 by Megger and TranscatBattery Testing 101 by Megger and Transcat
Battery Testing 101 by Megger and Transcat
 
The COST of Battery Maintenance_3.ppt
The COST of Battery Maintenance_3.pptThe COST of Battery Maintenance_3.ppt
The COST of Battery Maintenance_3.ppt
 
Degradation Curve effects and control technology.pptx
Degradation Curve effects and control technology.pptxDegradation Curve effects and control technology.pptx
Degradation Curve effects and control technology.pptx
 
P.p.t on types of electric cells
P.p.t on types of electric cellsP.p.t on types of electric cells
P.p.t on types of electric cells
 
Wet & dry batteries
Wet & dry batteriesWet & dry batteries
Wet & dry batteries
 
Battery (electricity)
Battery (electricity)Battery (electricity)
Battery (electricity)
 
Rechargeable Sodium-ion Battery - The Future of Battery Development
Rechargeable Sodium-ion Battery - The Future of Battery DevelopmentRechargeable Sodium-ion Battery - The Future of Battery Development
Rechargeable Sodium-ion Battery - The Future of Battery Development
 
Lecture 2 construction of lead acid battery 2
Lecture 2 construction of lead acid battery   2Lecture 2 construction of lead acid battery   2
Lecture 2 construction of lead acid battery 2
 
Paper battery2
Paper battery2Paper battery2
Paper battery2
 
Presentation on electronic battery
Presentation on electronic batteryPresentation on electronic battery
Presentation on electronic battery
 
Laptop battery repair
Laptop battery repairLaptop battery repair
Laptop battery repair
 
Li-Ion Batteries PPT.pdf
Li-Ion Batteries PPT.pdfLi-Ion Batteries PPT.pdf
Li-Ion Batteries PPT.pdf
 
Smart Battery Management System for Lithium Ion Battery
Smart Battery Management System for Lithium Ion BatterySmart Battery Management System for Lithium Ion Battery
Smart Battery Management System for Lithium Ion Battery
 
Next generation batteries
Next generation batteries Next generation batteries
Next generation batteries
 
Basic cells and batteries
Basic cells and batteriesBasic cells and batteries
Basic cells and batteries
 
A Study of the Factors that Affect Lithium Ion Battery Degradation
A Study of the Factors that Affect Lithium Ion Battery DegradationA Study of the Factors that Affect Lithium Ion Battery Degradation
A Study of the Factors that Affect Lithium Ion Battery Degradation
 

More from Intertek CE

CE Presentation
CE Presentation CE Presentation
CE Presentation Intertek CE
 
EMC Testing brochure
EMC Testing brochureEMC Testing brochure
EMC Testing brochureIntertek CE
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilitiesIntertek CE
 
Emc testing-brochure
Emc testing-brochureEmc testing-brochure
Emc testing-brochureIntertek CE
 
ETL Mark Fact-sheet
ETL Mark Fact-sheetETL Mark Fact-sheet
ETL Mark Fact-sheetIntertek CE
 
Hvac single-sheet-brochure
Hvac single-sheet-brochureHvac single-sheet-brochure
Hvac single-sheet-brochureIntertek CE
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilitiesIntertek CE
 
E uv usexplosiveareas
E uv usexplosiveareasE uv usexplosiveareas
E uv usexplosiveareasIntertek CE
 
Eu p power_supplies_im_final
Eu p power_supplies_im_finalEu p power_supplies_im_final
Eu p power_supplies_im_finalIntertek CE
 
Er p directive-televisions
Er p directive-televisionsEr p directive-televisions
Er p directive-televisionsIntertek CE
 
Ems pre reg_tips
Ems pre reg_tipsEms pre reg_tips
Ems pre reg_tipsIntertek CE
 
Emc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsEmc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsIntertek CE
 
Effects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsEffects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsIntertek CE
 
Eco design directive
Eco design directiveEco design directive
Eco design directiveIntertek CE
 

More from Intertek CE (20)

CE Presentation
CE Presentation CE Presentation
CE Presentation
 
EMC Testing brochure
EMC Testing brochureEMC Testing brochure
EMC Testing brochure
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilities
 
Emc testing-brochure
Emc testing-brochureEmc testing-brochure
Emc testing-brochure
 
ETL Mark Fact-sheet
ETL Mark Fact-sheetETL Mark Fact-sheet
ETL Mark Fact-sheet
 
Hvac single-sheet-brochure
Hvac single-sheet-brochureHvac single-sheet-brochure
Hvac single-sheet-brochure
 
Hvac brochure
Hvac brochureHvac brochure
Hvac brochure
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilities
 
S mark-en
S mark-enS mark-en
S mark-en
 
Intertek gs en
Intertek gs enIntertek gs en
Intertek gs en
 
Etl vs-ul-chart
Etl vs-ul-chartEtl vs-ul-chart
Etl vs-ul-chart
 
Wh mark
Wh markWh mark
Wh mark
 
E uv usexplosiveareas
E uv usexplosiveareasE uv usexplosiveareas
E uv usexplosiveareas
 
Eu p power_supplies_im_final
Eu p power_supplies_im_finalEu p power_supplies_im_final
Eu p power_supplies_im_final
 
Er p directive-televisions
Er p directive-televisionsEr p directive-televisions
Er p directive-televisions
 
Ems pre reg_tips
Ems pre reg_tipsEms pre reg_tips
Ems pre reg_tips
 
Emc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsEmc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systems
 
Emc safety
Emc safetyEmc safety
Emc safety
 
Effects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsEffects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designs
 
Eco design directive
Eco design directiveEco design directive
Eco design directive
 

Recently uploaded

Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...lizamodels9
 
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCRashishs7044
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadAyesha Khan
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Riya Pathan
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607dollysharma2066
 
International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...ssuserf63bd7
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailAriel592675
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...ictsugar
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfrichard876048
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Timedelhimodelshub1
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...lizamodels9
 
Investment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy CheruiyotInvestment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy Cheruiyotictsugar
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607dollysharma2066
 
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxContemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxMarkAnthonyAurellano
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024christinemoorman
 
Cybersecurity Awareness Training Presentation v2024.03
Cybersecurity Awareness Training Presentation v2024.03Cybersecurity Awareness Training Presentation v2024.03
Cybersecurity Awareness Training Presentation v2024.03DallasHaselhorst
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...lizamodels9
 
Market Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 EditionMarket Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 EditionMintel Group
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCRashishs7044
 

Recently uploaded (20)

Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
 
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
 
International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detail
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdf
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Time
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
 
Investment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy CheruiyotInvestment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy Cheruiyot
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
 
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxContemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024
 
Cybersecurity Awareness Training Presentation v2024.03
Cybersecurity Awareness Training Presentation v2024.03Cybersecurity Awareness Training Presentation v2024.03
Cybersecurity Awareness Training Presentation v2024.03
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
 
Market Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 EditionMarket Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 Edition
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
 

Battery white-paper-part-iii

  • 1. The Future of Battery Technologies – Part III Risks/Safety Factors for Lithium Batteries Dr. Annika Ahlberg Tidblad www.intertek.com 1
  • 2. This white paper is the third in our series on “The Future of Battery Technologies,” and provides an overview on the risks and safety factors associated with lithium batteries– common causes of external and internal battery faults, common issues to consider for primary and rechargeable batteries, and more. The white paper was authored by Dr Annika Ahlberg Tidblad, Intertek’s resident expert in battery testing. Her background is in research at KTH, the Swedish Royal Institute of Technology, with PhDs in applied electrochemistry and corrosion science, along with ten years of experience in battery technology. The Future of Battery Technologies – Part III – Risks/Safety Factors for Lithium Batteries One of the lithium battery's major strengths is its high energy density, but that is also why the risks of lithium-based chemistry are greater than in other battery systems, should anything go wrong. Although the risks are directly linked to the specific cell chemistry, cell size and the number of cells in the battery, there are certain common factors. Lithium batteries contain inflammable material in the form of organic electrolytes that have a low flash point and polymers that can maintain a fire and increase the risk of spreading to surrounding areas. The anode in primary lithium batteries consists of metallic lithium that melts at 180° and it reacts C, violently with water and air if the cell breaks or vents. The cells also contain several compounds that are toxic in themselves and which form harmful combustion products in the case of fire. One should always try to avoid exposing batteries to heat. This is partly because the cell chemistry may become unstable if the temperature is too high, which can lead to venting, and in the worst case scenario, to explosion and fire. Partly because heat accelerates the normal chemical processes taking place in the battery cell, and thereby such reactions and processes that lead to aging and loss of capacity, i.e. decomposition of both electrode and electrolyte material. Heat can either be generated by the cell itself or come from an external source. This is especially problematic if a multi-cell battery is exposed to uneven thermal conditions, as the cells will age at different rates, which may lead to problems in cell balancing. Cell balancing means that battery cells that must interact in one and the same stack are chosen in such a way that the cell capacity has as little spread as possible. A battery stack is never stronger than the weakest cell. Low temperatures can also pose a problem. Primary batteries generally only lose their function when it becomes too cold, which can be serious enough. Rechargeable batteries often have limited chargeability at low temperatures, and should not be charged if the ambient temperature is lower than the lowest recommended charge temperature, as it may lead to formation of metallic lithium which is precipitated as islands on the anode, so-called lithium plating, and forms dendrites that can cause interior short circuits in the cell. www.intertek.com 1
  • 3. Common External Causes of Battery Faults Some of the most common causes of battery faults originating from the user or application include: 1. External short circuit of the battery 2. Too high discharge or charge current 3. Pole reversal, i.e. discharge of a cell below 0V 4. Charging primary batteries 5. Incorrect or insufficient charge control of chargable batteries All five of these conditions generate heat to a varying extent in the battery cell, which leads to increased aging or breakdown of the cell. As these risks are caused by external factors, it is possible to prevent and avoid them. External short circuit When battery poles are short circuited, the high short circuit current leads to generation of a lot of heat in the cell. The most efficient way of preventing this from happening is to employ smart battery design that ensures that the + and - poles are physically isolated from each other, by countersinking them into the battery casing and designing them in such a way that it is not possible to connect the battery incorrectly. In certain cases, it may be necessary to integrate further forms of protection in the form of a fuse, or a PTC (Positive Temperature Coefficient) component, which breaks the electrical circuit if the current or the temperature begins to run away. Certain cell manufacturers integrate PTCs in their cells. It is also important to be aware of the risk of a short circuit when transporting individual cells or batteries. The rules that exist for packaging lithium cells and batteries, with or without equipment, are intended to prevent accidents from accidental short circuits. Too high discharge or charge current If the current is too high, the mass transport of the reactants for the main reactions is limiting, and the charge volume applied is partially consumed by other reactions in the cell, such as gassing and decomposition, which lead to increases in temperature. If the temperature increase is too high, it leads to further side reactions, which in turn generate even more heat. This increases the risk of venting and, in the worst-case scenario, uncontrolled cell reactions and thermal runaway. www.intertek.com 2
  • 4. When charging secondary cells, it is important not to exceed the recommended maximum charge current. If the charge current is too high, there is a risk of the lithium ions not managing to diffuse into the anode structure during charge, and instead being precipitated as lithium metal on the anode surface, which results in loss of capacity but also increases the risk of internal short circuits during subsequent use. Apart from current limiters, it is important that there is a low voltage protection to prevent any cell discharging below the lowest recommended voltage limit of the cell. In rechargeable batteries, the low voltage protection prevents the anode's base metal, usually copper, from dissolving and contaminating the cell. Li-ion cells that are heavily discharged risk both irreversible loss of capacity and increased self-discharge in subsequent use. Rechargeable batteries also need to be fitted with an over-voltage protection to prevent early aging, lithium plating on the anode, because cathodes that consist of metal oxides form unstable phases and lose oxygen to the surrounding area. Depending on the application and the complexity of the battery, it is not always sufficient with over-voltage and low voltage protection at the stack level, and control may have to be implemented on an individual cell level within the battery stack. Pole reversal Pole reversal can take place in battery stacks that consist of multiple cells connected in series. It is important to make sure that the cells in a multi-cell battery stack are well matched to begin with, and they are exposed to mainly the same loads and other conditions, so that the capacity continues to be evenly distributed. Otherwise, in the worst case scenario, the weakest cell could risk being heavily discharged and forced to reverse its poles, which means that the cell would be charged by the other cells, which are still being discharged. Multi-cell battery stacks usually have a cell-balancing function that distributes the current between the cells in a suitable manner. If the battery stack is fitted with low voltage protection, this may help to prevent pole reversal. Charging primary batteries Primary lithium batteries are not constructed to be charged. If this takes place, gas is formed within the cell, causing its internal pressure to rise. This may result in venting, or most seriously, in explosion. Primary lithium cells connected in parallel, and thereby exposed to a potential source of charging, should be protected by diodes. Incorrect or insufficient charge control of rechargeable batteries Charging is the single most risky element in the battery cycle, as energy is permitted to flow into the system from an external source. It is extremely important to comply with the charge www.intertek.com 3
  • 5. recommendations of the cell and battery manufacturers, both with respect to current limitation, voltage limitation and temperature, in order to ensure a long and safe battery life. The risks involved in too high charge current, exceeding the voltage limits, and too high and low temperatures, have been discussed above. Internal Causes of Battery Failure In addition to external fault sources, there are risks that may be difficult to predict or prevent, and which are caused by unsuitable cell design, manufacturing faults or ageing mechanisms within the battery cell, such as: 1. Weak or faulty seals that can cause leakage or failure 2. Pollutants that can lead to gas-developing secondary reactions, resulting in aging or venting due to overpressure in the cell 3. Internal short circuits caused by formation of dendrites on the electrodes, metal particles or faulty insulation of conductors, etc. Primary lithium batteries Primary lithium batteries have a higher energy density than the rechargeable Li-ion and Li- polymer cells. Small primary cells, e.g. coin cells, often lack the integrated safety components at cell level. Slightly larger cylinder batteries and prismatic cells often have so-called safety valves, which is a form of fuse, or PTC. The greatest safety risks are involved when a battery consists of several cells. In such cases, the cells should be soldered together in a battery stack to lower the risk of the user mixing different types of cell, and cell chemistries, when changing batteries. Even if the battery cells have integrated overheating protection, it is recommended that the battery is fitted with an external temperature limitation protector. The electrical protection must also include protection against charging, short circuit and a bypass connection protection that prevents pole reversal of an individual cell in a series, or a combination of serial and parallel connected cells. In certain cases, a battery must be fully discharged before a used battery can be disposed of safely as waste. If required, this takes place using a resistive load that gives a very low current flow. Rechargeable lithium ion batteries Most of us have seen and remember the scenes of burning laptops on the Internet, TV and in newspapers between 2006 and 2009. Studies of failures in the field showed that these were usually caused by an internal short circuit. The short circuit leads to the www.intertek.com 4
  • 6. cell's energy being discharged through a very limited volume, which leads to a rapid local temperature increase, reaching up to > 200° in sec onds. The heat induces the electrodes C and electrolyte to begin to decompose, and these reactions add further heat, tipping the cell into so-called thermal runaway in which the cell temperature and pressure increase exponentially over time. The overpressure leads to the cell venting, which liberates electrolyte aerosol in the surrounding area, and can easily ignite. In extreme cases, the cell splits or explodes unless the overpressure can be ventilated out sufficiently quickly. Depending on the construction of the cell and the internal positioning of the cells in a battery pack, the ignited electrolyte from one cell may heat up the adjacent cells and causes the cascade effect. Most Li-ion batteries on the market today indicate 60° as their upper usage temperature. The C majority of batteries currently on the market have graphite anodes. Graphite is not stable and can react chemically with the electrolyte in the cell. During manufacture and formation of the cell, a passive layer is formed on the anode surface, the SEI (Solid Electrolyte Interface) layer, which prevents continued reaction between the electrode and the electrolyte. As early as 90- 120° the layer can begin to break down, allowing exothermal gas evolving reactions to C, begin. If a sufficiently large area of the SEI layer breaks down, the cell may enter thermal runaway. Not all cells that develop an internal short circuit suffer thermal runaway. Factors that influence this include: • The size and location of the short circuit • The size and design of the cell • The active material in the cell; cobalt oxide is, e.g. more reactive than manganese dioxide and iron phosphate • Thermal properties of the various materials in the cells and the cells' abilities to disseminate heat • The cell’s state of charge, its age and history Internal short circuits caused by production factors may occur in all types of Li-ion cells and it is unlikely that it will be possible to completely eliminate this type of fault. There are various types of integrated protection at cell level that attempt to prevent and counteract risks. Figure 1 shows a cut-through of a cylinder cell. At the top of the cell there are 2 mechanical protectors in the form of a CID (current interrupt device) that triggers at a pressure of around 10 bar, and a safety valve. Both of these are irreversible, and the cell no longer works if either of these protectors is triggered. In addition, there is usually a PTC that throttles the current at temperatures over 125° This PTC function is rever sible and conduction restarts when the C. temperature falls. The separator between the anode and the cathode consists of 3 layers of polymer and is usually of the "shut-down" type, which means that when the cell temperature gets too high, around 165° the separator melts an d the pores close. The consequence is C, that the electric circuit is broken as the ion conduction in the cell ceases to function. This effect is irreversible. A number of additives have also been added to the electrolyte in the form of www.intertek.com 5
  • 7. flame retardants or inhibitors and redox shuttles. The role of the redox shuttle is to manage and consume any overcharge effect so that the cell voltage does not get too high. The cell container is also a part of the total protection which secures the cell's integrity against its surroundings. The increasingly more common "pouch" cells, i.e. cells with a soft coating that consists of a polymer-coasted metal foil, lack many of the mechanical protection components that are found in cylindrical and prismatic cells with steel or aluminium casing. Pouch cells have no integral CID, PTC or safety valve, but are completely dependent on external protection circuits. In the case of a strong overpressure, the cell's welded seams split, generally in vicinity to the pole connectors where the weld is the weakest. Nor are pouch cells as resistant to impact or puncturing as cells with metal casing. Figure 1 Cut-through of a Li-Ion cylinder cell Intertek’s expertise in battery testing & energy storage services ensures products meet performance, reliability and safety criteria. Intertek has expanded global energy storage testing facilities and advisory services. Throughout design, manufacturing & system deployment cycles, Intertek provides evaluations for performance, electrical safety, interoperability, fit for use, component selection and more. Please visit our website at www.intertek.com/energy-storage, contact icenter@intertek.com or call your regional lab: Europe: +46 8 750 00 00 North America: +1 800 967-5352 Asia Pacific: +86 21 6127-8200 www.intertek.com 6