What could you
    do with four                                                                                          Feedback

    channels?
                                                                                                          Analog/Digital



    Take multiple measurements
    simultaneously and track down the                                                     Safety control
    root cause of your most complex                                                                                        Output
    troubleshooting challenges.                                       Analog                                               Condition


                                                              Input                      Process/Display
                                                                      Digital




                                                                                     Power Supply
    Easily diagnose timing-related issues
    with multiple signals                                                                                          Transducers
    • Real-time inspection of multiple related                                                                     Measurements’
      signals simultaneously
    • Measure a combination of input and output        For industrial electronics, four channels allows you to
      signals and system safety interlocks and         perform three-dimensional testing, measuring input,
      feedback loops                                   output and feedback signals simultaneously.
    Find problems in industrial systems
    including:
    •   Circuit voltage/current overloading
    •   Attenuation/input impedance mismatch
    •   Signal fluctuation/drift
                                                         Mains           AC to DC     DC lter                 DC to AC converter
    •   Conditioning circuits signal integrity           supply         conversion   and buffer

    •   Test point verification for critical signals                                               +Vdc
    •   Input/output/feedback timing issues
    •   Induced noise and disturbances
    •   Random shutdowns/reset                           L1                           bus
                                                                                     voltage                                           T1
                                                                                                                                       T2
    Diagnose VSDs or power inverters and                 L2
                                                                                                                                       T3
    converters
                                                         L3
    • Harmonics, transients and loads in three-
      phase power input                                Gnd
    • Troubleshoot dc to ac converters for faulty                                                  -Vdc
      control circuits or output IGBT gate stages
    • Cable interface—test PWM output for reflec-         Mechanical
                                                           output
                                                                                         Motor (load)               Cable interface

      tions and transients
                                                                                                                                   T3

                                                                                                                                   T2

                                                                                                                                   T1




                                                       In three-phase systems like variable speed drives, UPS or
                                                       back-up generators, use four channels to diagnose power
                                                       input, dc to ac converters, or cable interface problems.




5

Weitere ähnliche Inhalte

Mehr von FlukeinMalta

ScopeMeter 190 Series II
ScopeMeter 190 Series IIScopeMeter 190 Series II
ScopeMeter 190 Series IIFlukeinMalta
 
Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011FlukeinMalta
 
Save Money with Fluke Thermal Imagers
Save Money with Fluke Thermal ImagersSave Money with Fluke Thermal Imagers
Save Money with Fluke Thermal ImagersFlukeinMalta
 

Mehr von FlukeinMalta (6)

ScopeMeter 190 Series II
ScopeMeter 190 Series IIScopeMeter 190 Series II
ScopeMeter 190 Series II
 
Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011
 
Save Money with Fluke Thermal Imagers
Save Money with Fluke Thermal ImagersSave Money with Fluke Thermal Imagers
Save Money with Fluke Thermal Imagers
 
Ti32 Data Sheet
Ti32 Data SheetTi32 Data Sheet
Ti32 Data Sheet
 
Ti25 manual
Ti25 manualTi25 manual
Ti25 manual
 
Ti25 data sheet
Ti25 data sheetTi25 data sheet
Ti25 data sheet
 

Fluke Scopemeter - 190 Series II

  • 1. What could you do with four Feedback channels? Analog/Digital Take multiple measurements simultaneously and track down the Safety control root cause of your most complex Output troubleshooting challenges. Analog Condition Input Process/Display Digital Power Supply Easily diagnose timing-related issues with multiple signals Transducers • Real-time inspection of multiple related Measurements’ signals simultaneously • Measure a combination of input and output For industrial electronics, four channels allows you to signals and system safety interlocks and perform three-dimensional testing, measuring input, feedback loops output and feedback signals simultaneously. Find problems in industrial systems including: • Circuit voltage/current overloading • Attenuation/input impedance mismatch • Signal fluctuation/drift Mains AC to DC DC lter DC to AC converter • Conditioning circuits signal integrity supply conversion and buffer • Test point verification for critical signals +Vdc • Input/output/feedback timing issues • Induced noise and disturbances • Random shutdowns/reset L1 bus voltage T1 T2 Diagnose VSDs or power inverters and L2 T3 converters L3 • Harmonics, transients and loads in three- phase power input Gnd • Troubleshoot dc to ac converters for faulty -Vdc control circuits or output IGBT gate stages • Cable interface—test PWM output for reflec- Mechanical output Motor (load) Cable interface tions and transients T3 T2 T1 In three-phase systems like variable speed drives, UPS or back-up generators, use four channels to diagnose power input, dc to ac converters, or cable interface problems. 5