2. The ALTAIR Pro Single-Gas Detector has a wide
> range of features, including simple intuitive
operation, small rugged design, and
dependable technology.
These innovative toxic gas and oxygen detectors are based upon the
design of the popular ALTAIR Single-Gas Detector, but with added
features and functionality.
> Tough rubberized housing > Versions available for CO, H2S, O2,
NH3, Cl2, ClO2, NO2, SO2, HCN,
> One-button operation and PH3
> Accurately measures gas > Great RFI performance
concentration or percent oxygen
> Adjustable alarm set points
> Displays information on a large, are offered for LOW, HIGH,
clear, backlit LCD. TWA, and STEL
> Superior dust and water protection > Alarms are indicated by flashing
(rated IP67 except O2-R) LEDs, audible alarm, and internal
> Event-logging and data-logging vibrating alarm
> Excellent impact resistance > Replaceable battery and sensor
The ALTAIR Pro Single-Gas Detector The ALTAIR Pro Single-Gas Detector
provides worry-free performance and is designed and built with MSA’s
stands up to the roughest handling in superior quality and is part of MSA's
even the toughest industrial ALTAIR Detector family of products.
environments. Sensors and battery
are easily replaced to keep the unit
performing for years.
The ALTAIR Pro Single-Gas Detector’s unique design combined with its highly competitive price makes it
the clear choice when selecting a single-gas detection instrument. It is accurate, reliable, durable, easy to
use, easy to maintain, and packed with features. The ALTAIR Pro Single-Gas Detector is designed and
manufactured by MSA, the most trusted name in the safety products industry.
MSAnet.com | 1.800.MSA.2222
3. Ease-of-Use Easily Replaceable, Commercially Rugged Design
The ALTAIR Pro Single-Gas Detector Available Battery Thick rubberized housing withstands
combines user flexibility and functional The detector runs on a single CR2 camera accidental drops or other impacts and also
simplicity. True single-button operation battery, simple to install and commercially provides additional water ingress resistance.
provides users with a clear path to any available. Installed battery life is Metal screw inserts offer stability over the
function. With a single button, users can: approximately 9,000 hrs (> 1 year). A unit’s lifetime. A durable suspension clip
long wake-up period each time units are completes this tough outer shell.
• turn the unit on. activated is avoided by supplying small
• activate the backlight. amounts of power to sensors even when Water and Dust Resistance
• activate the infrared link for units are powered off. The ALTAIR Pro Single-Gas Detector is
communication with a computer. highly water-and dust-resistant. Simple yet
• display information about the unit, such Remote Oxygen Detector (O2-R) effective design innovatively seals the unit,
as software version and alarm settings. The remote oxygen version for The ALTAIR exceeding the industry average IP rating.
• perform a fresh air setup (FAS). Pro Single-Gas Detector’s remote oxygen
sensor attaches remotely to the end of a Test and Calibration Stations
• initiate a bump test. MSA is proud to offer the ALTAIR
• change calibration gas concentration. ten-foot cable, rather than inside instrument
housing. Design allows users to lower the QuickCheck® Station, an easy and cost-
• initiate calibration. effective way to perform daily alarm
• reset peak reading display. sensor into remote locations and monitor
O2 levels from ten feet away. and gas response tests on your ALTAIR Pro
• manually change LOW, HIGH, TWA, STEL Single-Gas Detectors. The station is available
alarm set points (in protected SETUP Sensors in manual and automatic versions and
(mode only). The ALTAIR Pro Single-Gas Detector uses quickly verifies that the instrument is
• turn the unit off. fast-responding 20 Series oxygen and toxic ready for the upcoming day’s use.
Another ease-of-use feature is the built-in sensors and meets UL, cUL, ATEX, and
gas delivery adapter; no accessories are Australian standards. Sensors simply plug MSA also offers the ALTAIR Galaxy®
needed to conduct gas response tests, in to the internal circuit board for fast, Automated Test System for complete
eliminating hidden replacement costs. easy replacement. automatic calibration and record-keeping
of your ALTAIR Pro Single-Gas Detectors.
Distinctive Alarm System Built-In IR Communication Please contact MSA for additional
Triple alarm system leaves no doubt for users (Event & data logging) information on either of these stations.
in alarm situations. Piercing audio alarm Data logging is standard on the Altair Pro
averages 95 dB @ 1 foot and is designed to Single-Gas Detector. The unit automatically
be distinctive from other workplace sounds. records the 50 latest events in the session
Extended frequency range covers a wide log, while simultaneously recording peak
sound spectrum. Visual alarm features dual gas readings or low O2 readings every three
LED displays located on the unit’s top, visible minutes in a periodic data log. Combined,
from all angles. Internal vibrating alarm is also these two tools provide a great way to assess
standard on all units, emitting a pulse that alarm conditions, confirm bump tests or
directly calls additional attention to users calibration, and verify employee gas
when in alarm mode. concentration exposures.
To access data, simply link the unit to your
MSA infrared adapter using standard built-in
IR communication. MSA FiveStar® Link™
Software allows you to view various logs,
adjust alarm set points, assign the unit a
specific name, and disable or activate
particular features and options, a one-stop
unit control center.
MSAnet.com | 1.800.MSA.2222