SlideShare ist ein Scribd-Unternehmen logo
1 von 228
Downloaden Sie, um offline zu lesen
Estap 2012-2013 catalogue all pages
ESTAP HEAD OFFICE - SANCAKTEPE / İSTANBUL

ESTAP FACTORY - ESKİŞEHİR

40.000 m2 open area, 20.000 m2 closed area. Making production with 400 employess.
CONTENTS
FREE STANDING CABINETS
ServerMAX 	

600x1000 - 800x1000	

3-22

DCMax Datacenter solutions		

23-26

Universal Line 	
		
		
		
		

600x600 - 600x800 - 600x1000	
Universal Line JUMBO
800x600 - 800x800 - 800x1000
Universal Line PCcase
600x800

27-66	

EUROline 	
8
	 00x800 - 800x1000

600x600 - 600x800 - 600x1000	

67-88

ECOline	
8
	 00x800 - 800x1000

600x600 - 600x800 - 600x1000	

89-108

RELAYrack	
		

Single frame, D=600	
Double frame, D= 800, D=1000

109-116

PROline 	

600x450 - 600x560 - 600x(160+450) 	

117-130

PROline Residential	

600x150 - 600x300	

131-136

EUROline wall mounting	

600x450 - 600x600	

137-146

ECOline wall mounting 	

600x450 - 600x600	

147-156

WALL MOUNTING CABINETS

SOHOline wall mounting	
520x300 - 520x400	
	292x300 (10”)
SOHO Slimline		

157-166
167-168

OTHER PRODUCTS
Fiber Optic Boxes		

169-171

PDU		

173-174

Accessories 		
Free standing accessories
Wall mounting accessories

175-215

OUTDOOR ENCLOSURES		

217-224

QUALITY CERTIFICATIONS	

225

IP PROTECTION CLASS

226
	

NOTES		

227-228
ServerMAX free standing

•	 Compatible with all EIA-310 		
	 compliant 19” equipment.  All 	
	 type of servers, brands will 	 	
	 physically fit in ServerMAX 	 	
	 server cabinet.
•	 Bottom plate has an extra 	 	
	 perforated plate to prevent 	 	
	 insects or mice from reaching 	
	 the cables.
•	 Efficient passive air circulation
•	 Numbered U positions facilitate 	
	 easy installation of rack mounted 	
	 equipment.

3
ServerMAX free standing
600x1000 - 800x1000

ServerMAX free standing enclosure

26U	 36U	

42U	

47U

		

42U	

47U

	

600 x 1000*

800 x 1000*

ServerMAX protects your
technological investments
•	19”
•	HIGH QUALITY PRODUCTS
•	COMPLIMENTS YOUR DECOR AND 	
	 ENVIRONMENT
•	SECURE AND STURDY
•	EASY TO MAINTAIN: LARGE	INNER 	
	 VOLUME
•	HIGH SECURITY FOR UNAUTHORIZED 	
	 ACCESS
•	STRONG PROTECTION AGAINST 	 	
	 PHYSICAL DAMAGE
•	EXCELLENT PASSIVE AIR VENTILATION

* Please check drawing pages for cabinet sizes.
4
SERVERMAX FREE STANDING ENCLOSURES FOR	

STANDARD DIMENSIONS:
Heights: 26U, 36U, 42U, 47U
Width: 600 mm
Depth: 1000 mm
Heights: 42U, 47U
Width: 780 mm
Depth: 1000 mm
LOAD CARRYING CAPACITY: 1000 kg

600x1000 -800x1000

COLOUR:
RAL 9005 black
RAL 7035 light grey
STANDARDS:
ISO 9001 : 2008 Quality Management Systems
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for  
electronic equipment)
Overall cabinet dimensions for IEC 297-2

KEY FEATURES
Adjustable mounting depth: 19” mounting angles
are adjustable in depth for various mounts for adjustable
depth distance, please look at drawing pages.
Bottom plate: fitted with an additional plate to
prevent insects/vermin. If necessary a filter may be
integrated to prevent dust infiltration.
Bottom plate is complete with pre-punched removable
sections: when airflow comes from the floor, these
sections can be removed to provide efficient airflow
inside the cabinet.
Reversible doors: Front and rear doors may be
detached and reversed to allow the door to open from
the rear of the cabinet.
Side doors are split in two: Front section used to
access the cabinet; additional smaller section secured
inside the cabinet. If additional ventilation is necessary it
can be demanded as vented. The main inner strip of this
panel is designed for the housing of cables and power
strips.
Numbered “U” positions facilitate easy installation
for rack mounted equipment.
Vertical mounting rails with square holes;
adjustable in depth.

5
ServerMAX free standing
600x1000 - 800x1000

Optional plexi front door: May be used instead of
vented front door.  
All in one: ServerMAX includes; casters, doors, ground
studs, levelling feet, roof, bottom, side panels, C-rails, tilt bars,
unloaded fan tray.
Optimized depth: 1000 mm.Today and next generation
installation of servers, for power distribution and cable
management. 1000 mm is the optimum depth for comfort
cabling, housing server and gaining space in data centers.
Fixing to floor: ServerMAX can be easily fixed to the
floor when necessary.  A floor fixing kit is used for this
purpose. Please see accessories for floor fixing kit.
Efficient passive ventilation: New generation servers
and networking products need adequate ventilation to
operate efficiently. ServerMAX server cabinets provide

6

efficient passive ventilation because of its vented structure of
front and rear doors. Front and rear doors have maximum
perforation (%63) patterns for high-density cooling that meets
or exceeds server manufacturer’s ventilation requirements.
There is a fan tray on roof: Removable easily from
the top.When the maintanence of fans are required, it can be
reached directly from the top without touching any mounted
device or servers.
It is possible to attach a filter on top of the server fan unit.
Generous cable access holes are provided in the roof
and base. One on top, one on bottom holes are special ESTAP
style cable entries; sliding type with rubber edges.
FEATURES	

Quick release side doors: During installation and while
conducting routine maintenance of installed equipment, it is
often advantageous to remove the side panels. Quick release
slam latches and locks on the side panels allow for quick and
easy access.

600x1000 - 800x1000

Anti-tilt bars: As standard, ServerMAX is fitted with
2 sliding type tilt bars to make the cabinet stable in weight
center.  Whenever the servers are moved out, tilt bars are
drawn out to counter-balance the cabinets weight center.

Double opening rear doors improve access and
serviceability to rear of rack mounted equipment.The split
rear doors help to maximize floor space. Only 390 mm for
W=780 mm cabinets of clearance is required behind the
enclosure to allow for door swing.
D= 200 mm extention unit: If deeper equipment
is loaded into ServerMAX cabinets requiring additional
depth for cable radius, cable bundles, PDU housing etc, a
D=200mm extension unit may be installed to ServerMAX
cabinets: the rear door is removed and reinstalled onto the
extension unit. (Please see diagrams on pages 18-19)
Expansion: ServerMAX enclosures can be easily
expanded to create complete rows of enclosures without
side panels.  With a proper baying kit (please see accessories)
all cabinets are bayed easily and quickly.
Welded: Bottom and roof of the cabinet is completely
welded and a closed structure. Sturdy and rugged, it protects
against physical elements like dust, insects.
Lockable doors and side panels: Front and rear
doors are lockable using a 3 point locking mechanism.  
A handle-style locking system provides increased security to
prevent unauthorized access.  All doors and side panels are
only accessible with a key provided by ServerMAX.
Stability: Heavy duty frame design, 2 mm mounting rails,
angles, heavy duty type castor group provide 1000 kg load
rating.

7
ServerMAX free standing
FEATURES 	

600x1000 - 800x1000

Grounding: All parts are fitted with grounding studs to
provide electrical continuity.

Surface treatment: Fosfat coating, oil remove and
passivation.

Heavy duty vertical frames: Instead of 4ea. vertical
profiles, ServerMAX cabinets  are 6ea.(3ea.in left+3ea.in right)
main vertical profiles that gives extra stability for heavy loads.

Material thicknesses: Roof, bottom, vertical main frames,
1,5 mm C-rails, 19” mounting angles, profiles and all frames
are 2 mm  thickness. Sturdy steel construction.

More C rails: Instead of 6ea. there are 8 horizontal C rails
in depth for extra stability. (42U, 47U)

Paint: Electrostatic powder coating.

Reinforced bottom: Bottoms are reinforced with
horizontal profiles in width and depth for extra stability.
Rounded aesthetic monoblok front door: Front
door is a heavy duty type monoblock perforated and welded
structure. It’s shape is rounded in front to enhance the
aesthetics.

Easy to dismantle and assembly: The rigidly welded
frame construction can be dismantled and assembled easily
without any special tools.Thus, narrow doors, staircases and
lifts are no problem.  
Special cable entry on top and bottom case:
Bottom plate and top case have a special cable entry,
completely closed, sliding type with rubber edges.
Cables are entered and fixed.
Housing for cabling: The cabinet itself has enough
housing for vertical cable management at back. For 600x1000
cabinet, cable rings are used for cable management.
For 780x1000 cabinets there are special vertical cable
management panels of Ieft & right with cover plate for hiding
and protecting the cables.  These allow customers to easily
route, manage and access large numbers of data cables even
while an enclosure is loaded with rack mount equipment and
bayed in a row.
Power/energy distribution: Rear power distribution
housing at back of the cabinet provide easy access to multiple
receptacles.  Vertical power distribution strips can easily
be mounted in that space.  This housing never interfere
with equipment or takes any valuable “U” space.  Providing
increased accessibility to receptacles allows customers to
support more power cords within the enclosure.
Power strips are the length of cabinets: 26U, 36U, 42U, 47U.

8
ADDITIONAL FEATURES FOR 	

More Volume Width=780 mm:
Provides more efficient
cooling and more
professional cabling
ServerMAX Width=780 mm cabinet has all
features mentioned before. Plus these additional
features.

800x1000 mm

Vertical cable management panels can be used at
rear of the cabinet  for professional cabling and to hide the
power cables.
Extra Housing space for cabling and power
distribution: This extra space provides housing for the
vertical cable management panels and the vertical power
strips.

Left and right front panel: Front panels can be used to
hide unwanted views of cables. If server cabinet is additionally
used for networking in the front, cable management is needed:
Estap cable rings can be used to attach this panel and secure
cables.Access holes allow the patch cord to reach the rear of
cabinet.

9
ServerMAX free standing
SELECTION STEPS FOR	

600x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure for ServerMAX W=600 mm:
	

Product range name	

+	

U height (HHU)

The product options have the below structure:
	

Colour option (MX)	

+	

Front door option (FX)	

+	 Rear door option (RX)

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example : SRV42U (Width=600 mm)
	
Step 2
Please choose the colour from the table and place it after the part number.
For example : SRV42U - M01 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
	
For example : SRV42U - M01 - F15 (FX= look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example : SRV42U - M01 - F15 - R07 (RX= look at the RX rear door options on the next page)

10
PART NUMBER DEFINITION FOR 	

600x1000

FX***

MAIN PART NUMBER STRUCTURE
	

SRV 	
Product
range
ServerMAX

F14**

U
height

+

SRV

Front door options

- 	HHU

600

HHU
26U
36U

SRV

42U
47U

H

SRV	:  ServerMAX product range  (W=600 mm)
HHU	:  “U” height
WD	:  600x1000 mm

Front view

F15
	
	

R07*

600

OPTIONS

MX 	 - 	 FX 	

MX

- 	 RX

Front
door
options

Colour
options

+

FX

M01

F14**

M02

600

Rear
door
options

+

RX
R07*

F15

H

H

R07*

MX	:	
Colour options
	
	 M01= RAL 9005 black 	
	
	 M02= RAL 7035 light grey

Front view

Front view

RX***
Rear door option

FX	: 	Front door options
	
	 F14**= Single opening, monoblock,welded, curved %63 	
	
	 perforated door, 3 point handled locking             
	
	 F15= Single opening, monoblock,welded, curved plexi glass 	
	
	 door, 3 point handled locking

R07*
600

RX	:	 Rear door option
	
q	 R07*= Double opening %63 perforated door with 	 	
	
	 complete metal frame, 3 point handled locking

H

Back view
H= Enclosure height
* R07 is the standard rear door.
** F14 is the standard front door.

*** F14, F15 R07 can be used as front or rear door.
11
ServerMAX free standing
TECHNICAL DRAWINGS FOR 	

600x1000 - 26U/36U/42U/47U

R07* / ***

F14** / ***
F15***

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with casters
(mm)

ServerMAX cabinets 19” 600 x 1000 mm

SRV26U

26U 600x1000 mm

26

600

1000

740

1179

1291

1338

SRV36U

36U 600x1000 mm

36

600

1000

740

1623

1735

1782

SRV42U

42U 600x1000 mm

42

600

1000

740

1890

2002

2049

SRV47U

47U 600x1000 mm

47

600

1000

740

2112

2224

2271

*  R07 is the standard rear door.
** F14 is the standard front door.
*** F14, F15, R07 can be used as front or rear door.

12
TECHNICAL DRAWINGS FOR	

600x1000 - 26U/36U/42U/47U

565
200

180

(Min 795)
740

H

Front view

Bottom view

Mounting profile
1000

12

600

F14**

(Min 25)
56

140

140

906

200

(Min 158)
184

600

600

F15

H

Front view

47

H

Side view

Back view

Front view

600
200

R07*

1000

200

600

30

H

Top view
H= Enclosure height

Iso view

Front view
*R07 is the standard rear door.
** F14 is the standard front door.

13
ServerMAX free standing
PART NUMBER DEFINITION FOR	

800x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure for ServerMAX W=780 mm:
	

Product range name	

+	

U height (HHU)	

+ 	 Width (WW, D=1000 mm)

The product options have the below structure:
	

Colour option (MX)	

+	

Front door option (FX)	

+	

Rear door option (RX)

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example : SRV42U8 (Width=780 mm)
	
Step 2
Please choose the colour from the table and place it after the part number.
For example: SRV42U8 - M01 (MX= Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
	
For example: SRV42U8 - M01 - F16 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: SRV42U8 - M01 - F16 - R08 (RX= Look at the RX rear door options on the next page)

14
PART NUMBER DEFINITION FOR	

800x1000

FX***

MAIN PART NUMBER STRUCTURE

Front door options

	 SRV 	 - 	HHU 	- 	 WW
Product
range
ServerMAX

SRV

Width
&
depth=
1000 mm

U
height

+

HHU

+

780

8

42U
SRV

F16**

WW

47U

H

SRV	:  ServerMAX product range  
HHU	:  “U” height
WW	:  Width (W=780 mm)

	

OPTIONS
	

MX	 - 	 FX	

-	 RX	

Front
door
options

Colour
options

MX

Front view

+

FX

M01

F16**

M02

F17

R08*

780

780

Rear
door
options

+

RX

F17

R08*

H

H

R08*

MX	:  Colour options
	
	 M01= RAL 9005 black
	
	 M02= RAL 7035 light grey

Front view

Front view

RX***
Rear door option

FX	:  Front door options
	
	 F16**= Single opening, monoblock, welded, curved %63 	
	
	 perforated door, 3 point handled locking
	
	 F17= Single opening, welded, curved plexi glass door,
	
	 3 point handled locking

R08*
780

RX	: 	Rear door option
	
	 R08*=  Double opening %63 perforated door with 	
	
	 complete metal frame, 3 point handled locking
	

H

Back view
H= Enclosure height
* R08 is the standard rear door.
** F16 is the standard front door.

*** F16, F17 R08 can be used as front or rear door.
15
ServerMAX free standing
TECHNICAL DRAWINGS FOR	

800x1000 - 42U/47U

R08*/***

F16**/***
F17***

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with casters
(mm)

ServerMAX free standing cabinets 19” 780 x 1000 mm

SRV42U8

42U 780x1000 mm

42

780

1000

740

1890

2002

2049

SRV47U8

47U 780x1000 mm

47

780

1000

740

2112

2224

2271

*  R08 is the standard rear door.
** F16 is the standard front door.
*** F16, F17, R08 can be used as front or rear door.

16
TECHNICAL DRAWINGS FOR	

800x1000 - 42U/47U

780

745

F16**

(Min 762)
740

H

(Min 27)
44

140

140

906

200

(Min 190)
195

300

280

19”
Mounting profile

Bottom view
1000

780

12

780

Front view

H

H

Side view

47

Front view

F17

Back view

Front view

780

780

R08*

200

300

Top view
H= Enclosure height

29

1000

H

Iso view

Front view
* R08 is the standard rear door.
** F16 is the standard front door.

17
ServerMAX free standing
TECHNICAL DRAWINGS FOR	

600x1000

Technical drawing of extention unit D=200 mm for 600x1000 mm ServerMAX
Top view after extention unit
600

70

200

145

Note: Depth of existing cabinet + 200 mm
Exploded view

Iso view

Part
number

Width:
overall
(mm)

Depth:
overall
(mm)

Height:
without
levelling feet
(mm)

Height:
with casters
(mm)

SRV26U EXT620

26U Extention unit D=200 mm, suitable for ServerMAX W=600 mm

26

600

200

1281

1328

SRV36U EXT620

36U Extention unit D=200 mm, suitable for ServerMAX W=600 mm

36

600

200

1726

1773

SRV42U EXT620

42U Extention unit D=200 mm, suitable for ServerMAX W=600 mm

42

600

200

1993

2040

SRV47U EXT620

18

Product definition
(mm)

U
Size

ServerMAX 19” 600 x 1000 mm extention unit

47U Extention unit D=200 mm, suitable for ServerMAX W=600 mm

47

600

200

2215

2262
TECHNICAL DRAWINGS FOR 	

800x1000

Technical drawing of extention unit D=200 mm for 780x1000 mm ServerMAX
Top view after extention unit
780

70

200

145

Note: Depth of existing cabinet + 200 mm

Exploded view
Iso view

Part
number

Product definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Height:
without
levelling feet
(mm)

Height:
with casters
(mm)

ServerMAX 19” 780 x 1000 mm extention unit

SRV42U EXT820

42U Extention unit D=200 mm, suitable for ServerMAX W=780 mm

42

780

200

1993

2040

SRV47U EXT820

47U Extention unit D=200 mm, suitable for ServerMAX W=780 mm

47

780

200

2215

2262

19
ServerMAX free standing
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment	 	
	
EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, 	
IEC60917 and IEC60297
Industrial environment 	
EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297
Statical mechanical structure load test 	
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability 	
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, 	
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and flame resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree 	
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and	
IEC60297
Transportation
ETS300019-1-2 Class 2.3
Storage
ETS300019-1-1 Class 1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530,  TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS
20

KEY FEATURES

Main profile (framework) has an aesthetic structure which
increases mechanical resistance, folded at an angle of 90
degrees and consisting of 4 bends for each profile. In total;
16 folds provide framework stability.Additionally, 2 piece
vertical side panel divider profile provides additional
resistance each with a 4 fold design; total of 8 fold additional
support. In total ServerMax main profile framework consists
of a 24 fold engineering design. Manufactured and tested to
provide axial (x, y, z) resistance that meets EN 61587-1 / 5.2.1
and 5.2.2, and external impact resistance that meets
EN 61587-1 / 5.3.3.  
Bottom and upper cases have a structure to increase
the resistance and strength of the cabinet by monoblock
bended, welded and profile-interlocking design. Profiles are
manufactured to interlock bottom and upper cases with
screws.  The bottom case providing cable access is fitted with
a sliding blanking access plate to prevent dust.
A rubber edge on the cable access plate and sliding structure,
it is possible to fix the cables and allows cables to be placed
into the cabinet without any damage.
Additional there are pre-punched knock outs for air
distribution delivered from raised floor.  
Rear door in standard configuration is a double opening
door which is removable and lockable. Integral locking is a 3
point locking system.
Rear doors can be opened up to 215 degrees, are removable
and lockable with handle type locking unit.
Side panels have a structure that can be opened and
removed with slam latch and key.They are lockable and
removable. Side panels consist of a divider profile which
creates 2 pieces side panels on each side. Original functional
side panel is lockable and removable as mentioned above;
the smaller side panel is fixed from inner side with screws.
If additional ventilation is needed this panel can be replaced
with a slotted / perforated one.
Within this engineering construction, the original functional
side panel becomes easy to carry while the divider profile
provides better resistancy.
Front doors are single opening, monoblock, welded, curved,
%63 perforated in standard. Integral locking as 3 point locking
system. For options please see the related diagrams and
technical charts in pages 11-15.
Front door can be opened up to 215 degrees, removable and
lockable with handle type locking unit.
Vented top panel housing with a dedicated space for
ventilation, the fan module system allows easy installation of
max. 6 fans from top.
19”(inch) mounting angles (2ea. in front and 2ea. in rear) are
part of cabinet interior configuration and adjustable in depth.
Baying is possible for side by side applications without
side panels. Levelling feet and integrated castor group are
standard in shipping configuration.
The cabinet meets EN 61587-1, IEC 60917, IEC 60297
standards, RoHS compliancy, Gost and TSE certified.
Cabinets are manufactured in our factory which has
ISO 9001: 2008 Quality Assurance System and our
responsibility for enviroment with ISO 14001:2004
Environmental Management System.
TECHNICAL SPECIFICATIONS

Custom number
85380000 / 85381000 / 853710990019
Packs of (ea.)
1
Shipping structure
Assembled
Mounting surface
Stand alone
Load carrying capacity (kg)
1000
Certification on product
TSE, Gost
Surface finish
Electrostatic powder coated c/with surface treatment , 80 +/ - 5
micron paint thickness and tested according to IEC  60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11
STANDARD PRODUCT
Standart colour
RAL 7035, RAL 9005
Baying
Possible with baying kit for side by side applications without side
panels  
IP protection standard
IP20
FRONT DOOR
Single opening, monoblock, welded,curved, %63 perforated
Front door construction
Monoblock curved, welded construction
Front door lock
Handle type, 3 point locking
Hinge system
Spring loaded
Door opening angle and swapping
215 degree

Door opening angle and swapping
215 degree
FRAMEWORK                   
Top and bottom base units
Solid Metal 2 mm
Top and bottom base units construction
Completely welded corner socket system
Uprights
Solid metal, 2 mm
Uprights construction
Tightly fixed into top and bottom base units
3 times folded 3 x 2 = 6 folds
SIDE PANEL DIVIDER PROFILE
Solid metal 2 mm
Side panel construction
Tightly fixed into top and bottom base units
4 times folded x 2 = 8 folds
INTERIOR PARTS                    
19’’ mounting angles
Solid metal, 2 mm
1 times folded for an L profile system
U marking available
2 ea. at rear, 2 ea. at front
Pre-configured as 19’’
Zinc plated, passivated, 8-12 micron
Adjustable in depth
Omega type support rails in depth
Solid metal, 1,5 mm
3 times folded for W=600 mm cabinets
Omega type folded for W=780 mm cabinets
3 ea. at left, 3 ea. at right  26U and 36U
4 ea. at left, 4 ea. at right  42U and 47U

SIDE PANEL
Solid metal, 1 mm. Left and right (2ea.)
Construction
Lockable, removable c/with slam latches and lock
Lock
Barrel type lock unit, single point + slam latch (2ea)
REAR DOOR
Solid metal, 1 mm
Rear door construction
Double door opening, %63 perforated, lockable, removable
Rear door lock
Handled type lock unit, 3 point
Hinge system
Spring loaded

For CUSTOMIZED PRODUCTS rather than
above options, please contact sales department.  

21
ServerMAX free standing accessories
FREQUENTLY USED ACCESSORIES SELECTION CHART FOR SERVERMAX

Estap has a wide range of accessories: Heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable
managements, cable rings, organisers, trays, plinths and so on...
* See the other and part number definition on pages 173-213.

* Please state colour choice in your orders. 	

M01=RAL 9005 black and M02= RAL 7035 light grey

Frequently used accessories selection table

ServerMAX / Vertical PDU part numbers
M44 24 AL IEC AMP MCB

ServerMAX / Cable management unit
(suitable for 780x1000 Server Cabinets)

Enclosure sizes*
800x1000

42U

M44ORG42SRV

47U

M44ORG47SRV

ServerMAX /
Cable management rings

Part number

44x30

K44RING01

44x60

K44RING021U

44x110

K44RING03

70x160

K44RING04

ServerMAX /
Floor fixing kit

Enclosure sizes*
600x1000
800x1000
M44DPR03

22

* Please check drawing pages for cabinet sizes.

M44DPR04
Data Center solutions

’Data center solutions
which is mission critical,
require reliable, flexible
and scalable infrastructures
alongside guarantied high
performance.
ESTAP OFFERS energy efficient
MANAGABLE, MEASURABLE AND
SCALABLE SOLUTIONS TO DATA
CENTER PROJECTS.

23
Data Center

solutions

MAIN FEATURES
DCMax data center server cabinets are designed to provide
hot corridor, cold corridor and its containment structure,
which has been widely used in enterprise datacenters.
Design criteria serves to provide:
•	 Maximum performance for cooling of IP20 and IP55 		
	solutions
•	 Wide range of cabinet sizes and accessories
	 H=42/47U – W=600/800 mm – D=1000/1100/1200 mm
•	 Load capacity= 1500 kg. DCMax structure is suitable for 		
	 carrying heavy loads and is seismic tested to 1000 kg
	 (BELLCORE GR-63-CORE ZONE 4, NEBS)
•	 Maximum inner space for servers
•	 Minimum environmental space requirement
•	 Professional cable management
•	 Heavy duty structure
•	 Compability with all vendors servers
•	 High technical performance, grounding continuity
•	 Power / energy management
•	 Controllable and reliable security with monitoring
•	 Aesthetic and professional design

19” OPEN FRAME CABLING CABINET, IP20
Estap System Rack cabinet series offers an ideal solution
for the data center which include high density cabling
and need effective cooling. Its heavy-duty structure
is suitable to house the component of the network
backbone.

24

HOT & COLD CORRIDOR APPLICATIONS
Estap datacenter cooling solution offers real and energy
efficient cooling with its wide product range such as
water chilled sidecoolers, in-row coolers, heat removal
units, cold corridor containment and so on.
Data Center solutions

LCD CONSOLES & KVM
The high quality KVM switch is ideal for use in small to middle sized server
rooms and provides direct connection to many servers.
Estap consoles with/without integrated KVM are a space saving and
functional solution for a comfortable connection to PCs, servers KVM
installations in a 1U rack-mounting area.

REMOTE MONITORING SYSTEM
Supplies real time monitoring and
management solution for data centers
to secure flawless operation with high
resilien.

POWER DISTRIBUTION UNITS (PDU)	
Estap managed IP PDUs provide reliable power distribution
and monitoring of individual outlets to data centers, for both
Blade servers.
Designed for high density, mission critical server applications,
Estap IP PDU range offers an excellent solution to scale
electrical power budgets and fight against the inevitable rise of
electrical energy costs in the data center business.

25
Data Center

solutions

Data Center solutions

ESTAP
Data center
COOLING
SOLUTIONS
Estap data center IT cooling
solution ensures maximum
IT availability at minimum running
cost. The power usage effectiveness
in the data centers indicates
that approximately %30 of the
total incoming power is utilised
by cooling and cooling related
equipment.

FEATURES
Cold corridor

• Liquid / gas cooling
• High cooling capacity
• Easy mounting and maintenance

ESTAP DATA CENTER COOLING SOLUTIONS
Hot corridor

26

In Row coolers are utilised. To serve for cooling and/or
enhancing the cooling capacity of a cold corridor containment.
Heat rejection can be handled by an existing chilled water system:
The modular solution serve scalable cooling capacity growth.
Universal Line free standing

•	 Provides unique features for 	 	
	 system designers, installers and 	
	 network managers.
•	 Suitable for office, equipment 	
	 room and cabling closet 	
	
	 installations
•	 Exceptionally sturdy and strong
•	 Highly cost-effective and 	
	
	 assembly-friendly solutions 	 	
	 for numerous applications
•	 Multiple cable entry points 	 	
	 provide maximum versatility
•	 Delivered as assembled and side 	
	 by side mounting is possible

27
Universal Line free standing enclosures
600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000

Universal Line free standing enclosures

	16U	 20U	22U	 26U	 32U	

	 26U	 36U	

42U	

36U	

39U	

42U	

44U	

47U

600 x 600*

600 x 800*

600 x 1000*

47U

Universal Line JUMBO free standing enclosures

32U	

	

	

	

42U	

36U	

39U	

42U	

44U	

47U

800 x 1000*

47U

Universal Line PCcase

36U	

600 x 800*

Highly cost-effective and
assembly-friendly solutions
for numerous applications

* Please check drawing pages for cabinet sizes.

28

800 x 600*

800 x 800*
UNIVERSAL LINE ENCLOSURES FOR	

STANDARD DIMENSIONS:
Heights:16U, 20U, 22U, 26U 32U, 36U, 39U,
42U, 44U, 47U
Width: 600 mm
Depth: 600 mm - 780 mm
Heights: 26U, 36U, 42U, 47U
Width: 600 mm
Depth: 1000 mm
LOAD CARRYING CAPACITY:  600 kg

600x600 - 600x800  - 600x1000

COLOUR:
RAL 9005 black
RAL 7035 light grey
STANDARDS:
ISO 9001: 2008 Quality Management Sytem
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for  
electronic equipment)
Overall cabinet dimensions for IEC 297-2

KEY FEATURES
• The Universal Line free standing cabinets are suitable for
office, equipment room, housing server and cabling closet
installations. Attention to style with attractive colours
black RAL 9005 and light grey RAL 7035 and smoked
glass door reinforced with vertical left and right metal
frames means that cabinets can be deployed in the most
demanding of office environments where appea counts.
• However, Universal Line are an exceptionally sturdy and
strong cabinet enabling usage for all applications.
• Front door frames are available with orange decorative
stripe.
• The Universal Line offers a highly cost-effective and
assembly-friendly solution for numerous applications in
the field of network technology and electronics.  The
Universal Line is highly configurable to the end users
requirements and provides unique features to benefit
system designers, installers and network managers.
• Standard cabinet is completely assembled and delivered
as a single enclosure.
• Side by side mounting is also possible when side panels
are not used; baying kits to be added.
• The rigid welded frame construction can be
disassembled and assembled easily without any special
tools.  Thus narrow doors, staircases and elevators are
no problem.

29
29
Universal Line free standing enclosures

Universal Line free standing enclosures
offer a wide range of options.

30
UNIVERSAL LINE FREE STANDING ENCLOSURES FOR 	

600x600 - 600x800 - 600x1000

EASY TO ACCESS
Front door
Features a full-length smoked and shatterproof glass
door with decorative accent stripe reinforced with
left/right metal frames and integral locking mechanism.
Side doors
Lockable, removable, complete with slam latches and
barrel type locks.

19” mounting angles (front/2ea and back/2ea) allow for
flexible configuration and are adjustable in depth.
C rails 3 fold 1,5 mm thickness to increase the stability
of equipment .
Levelling feet included as a standard feature.

Rear door
Lockable, removable lock.
Secure, locking front and back doors with spring loaded
hinges offer best accessibility even when connecting
the cabinets. The door hinge is easily swapped from
one side to the other to change the direction the door
opens.
Giving you 4-way access to equipment. Front and rear
door can be replaced giving you flexibility for different
installations.
CABLE ACCESS
Multiple cable entry points provide maximum versatility.
There is a rubber edge sliding cover mechanism that
protects and fix the cables.  There is a brush on the rear
panel that can be positioned on top or bottom (brush
entry available on height of 26 U and above)
CONSTRUCTION
Rigid welded frame construction in steel sheet, rapidly
disassembled with 4 screws per corner. Corners of base
has welded sockets that tightly fixed into the columns
give maximum stability.
Frames are made with a 24-fold design for increased
stability.
Vented Pagoda style top cover with built-in space for
available top mount ventilation fan system providing
protection against dust flow from the top, additionally
this causes a chimney effect to provide passive air flow
via convection.

31
Universal Line free standing
SELECTION STEPS FOR	

600x600 - 600x800

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
	 roduct range name	

+	

U height (HHU)	

+	

Width&Depth (WD)

+	

Rear door option (RX)

The product options have the below structure:
C
	 olour option (MX)	

+	

Front door option (FX)	

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U66
	
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U66 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
	
For example: CKR42U66 - M02 - F01 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U66 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page)

32
PART NUMBER DEFINITION FOR	

600x600 - 600x800

FX

MAIN PART NUMBER STRUCTURE
	

CKR 	
Product
range
Universal Line

F01*

Width
&
Depth

U
height

+

CKR

Front door options

- 	 HHU 	 - 	 WD

+

HHU

F02

600

600

WD

16U
20U
22U
26U
32U

H

66

36U

CKR

H

68

39U
42U
44U

Front view

47U

Front view

F03

CKR	:  Universal Line free standing product range  
HHU	:  “U” height
WD	:  Width and depth

F04

600

600

								
OPTIONS

	
	

MX 	

-	

- 	 RX**

Front door
options

Colour
options

MX

FX	

+

FX

Rear door
options

+

H

H

RX

M01

F01*

R01

M02

F02

R02

F03

* 	 F01 is the standard front door.
**	RX - R01 is standard rear door for 22U and below, is optional door for 26U and above
	 R02 is standard rear door for 26U and above with 2 brushed cable access part

Front view

RX**
Rear door options
300

R02
55

MX	:	
Colour options
	
	 M01= RAL 9005 black 	
	
	 M02= RAL 7035 light grey
FX	: 	Front door options
	
	 F01*= Single opening shatter proof glass door with left and 	
	
	 right metal frame slotted, single point handled locking
           	 	 F02= Single opening shatter proof glass door with complete 	
	
	 metal frame slotted, single point handled locking
	
	 F03= Single opening solid metal door, single point handled 	
	
	 locking
	
	 F04= Single opening %63 perforated door with complete 	
	
	 metal frame slotted, single point handled locking
RX**	:	 Rear door options
	
	 R01= Single opening solid metal rear door with barrel type 	
	
	 single point lock unit for 22U and below
	
	 R02= Single opening solid metal rear door with barrel type 	
	
	 single point lock unit with brushed cable entry, for 26U and 	
	
	 above

Front view

R01
600

55

F04

H= Enclosure height

300
Back view

Back view

33
Universal Line free standing
TECHNICAL DRAWINGS FOR	

600x600 - 16U/20U/22U

R01**

F01*

F02

F03

F04

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line free standing cabinets 19” 600 x 600 mm

CKR16U66

16U 600x600

16

600

600

390

715

865

880

945

CKR20U66

20U 600x600

20

600

600

390

890

1042

1057

1122

CKR22U66

22U 600x600

22

600

600

390

980

1131

1146

1211

* F01 is the standard front door.
** R01 is the standard rear door for 22U and below.

34
TECHNICAL DRAWINGS FOR 	

600x600 - 16U/20U/22U

600

395

F01*
(Min 30)
111

300

(Min 520)
390

478

200

H

(Min 45)
95

Front view

Bottom view

600

19”

F02

Mounting profile

H

600

600
Front view

600

F03

H

Side view

Front view

H

Back view

Front view

600

600

600

F04

H

Top view
H= Enclosure height

Iso view

Front view
* F01is the standard front door.

35
Universal Line free standing
TECHNICAL DRAWINGS FOR	

600x800 - 16U/20U/22U

R01**

F01*

F02

F03

F04

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line free standing cabinets 19” 600 x 780 mm

CKR16U68

16U 600x780

16

600

780

555

715

865

880

945

CKR20U68

20U 600x780

20

600

780

555

890

1042

1057

1122

CKR22U68

22U 600x780

22

600

780

555

980

1131

1146

1211

* F01 is the standard front door.
** R01 is the standard rear door for 22U and below.

36
TECHNICAL DRAWINGS FOR	

600x800 - 16U/20U/22U

600

F01*

395

200

(Min 30)
130

300

658

(Min 701)
555

H

(Min 45)
91

Front view

600

F02

19”

Bottom view

Mounting profile

H

600

780
Front view
H

600

F03

H

H

Front view

Side view

Back view

Front view

600

600

780

F04

H

Top view
H= Enclosure height

Iso view

Front view
* F01is the standard front door.

37
Universal Line free standing
TECHNICAL DRAWINGS FOR 	

600x600 - 26U/32U/36U/39U/42U/44U/47U

R02**

F01*

F02
F03
F04

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line free standing cabinets 19” 600 x 600 mm

CKR26U66

26U 600x600

26

600

600

390

1160

1309

1324

1389

CKR32U66

32U 600x600

32

600

600

390

1422

1576

1591

1656

CKR36U66

36U 600x600

36

600

600

390

1603

1754

1769

1834

CKR39U66

39U 600x600

39

600

600

390

1735

1887

1902

1967

CKR42U66

42U 600x600

42

600

600

390

1868

2021

2036

2101

CKR44U66

44U 600x600

44

600

600

390

1960

2110

2125

2190

CKR47U66

47U 600x600

47

600

600

390

2093

2244

2259

2324

* F01 is the standard front door.
** R02 is the standard rear door for 26U and above.

38
TECHNICAL DRAWINGS FOR 	

600x600 - 26U/32U/36U/39U/42U/44U/47U

600

F01*

395

H

(Min 520)
390
(Min 45)
95

478

200

(Min 30)
111

300

Bottom view

Front view

F02

600

19”

Mounting profile
600

300
55

600

H

Front view
600

F03

55

H

Front view

H

300
Back view

Side view

600
Front view

F04

600

600

H

Top view
H= Enclosure height

Iso view
Front view
* F01 is the standard front door.

39
Universal Line free standing
TECHNICAL DRAWINGS FOR	

600x800 - 26U/32U/36U/39U/42U/44U/47U

R02**

F01*

F02
F03
F04

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line free standing cabinets 19” 600 x 780 mm

CKR26U68

26U 600x780

26

600

780

555

1160

1309

1324

1389

CKR32U68

32U 600x780

32

600

780

555

1422

1576

1591

1656

CKR36U68

36U 600x780

36

600

780

555

1603

1754

1769

1834

CKR39U68

39U 600x780

39

600

780

555

1735

1887

1902

1967

CKR42U68

42U 600x780

42

600

780

555

1868

2021

2036

2101

CKR44U68

44U 600x780

44

600

780

555

1960

2110

2125

2190

CKR47U68

47U 600x780

47

600

780

555

2093

2244

2259

2324

* F01 is the standard front door.
** R02 is the standard rear door for 26U and above.

40
TECHNICAL DRAWINGS FOR 	

600x800 - 26U/32U/36U/39U/42U/44U/47U

395

600

F01*

200

(Min 30)
130

300

(Min 45)
91

658

(Min 701)
555

H

Bottom view

Front view

F02

600

19”

Mounting profile
780

300
55

600

H

Front view
600

F03

55

H

H

300
Front view

Side view

Back view

600
Front view

F04

780

600

H

Top view
H= Enclosure height

Iso view
Front view
* F01is the standard front door.

41
Universal Line free standing
SELECTION STEPS FOR 	

600x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
	 roduct range name	

+	

U height (HHU)	

+	

Width&Depth (WD)

+	

Rear door option (RX)

The product options have the below structure:
C
	 olour option (MX)	

+	

Front door option (FX)	

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U6100
	
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U6100 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
	
For example: CKR42U6100 - M02 - F01 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U6100 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page)

42
PART NUMBER DEFINITION FOR 	

600x1000

FX

MAIN PART NUMBER STRUCTURE
	

CKR 	
Product
range
Universal Line

CKR

Front door options

- 	HHU 	- 	WD

+

HHU

F05*

Width
&
Depth

U
height

+

F06

600

600

WD

26U
6100

36U

CKR

42U
47U

H

CKR	:  Universal Line free standing product range  
HHU	:  U height
WD	:  Width and depth

H

Front view

Front view

F07
	 OPTIONS

F08

600

	

600

MX 	 - 	 FX 	 - 	 RX
Front
door
options

Colour
options

MX

+

FX

Rear
door
options

+

RX

F05*

R01

M02

F06

R02*

F07

R03

F08

F04

MX	:	
Colour options
	
	 M01= RAL 9005 black 	
M02= RAL 7035 light grey
FX	: 	Front door options
	
	 F05*= Single opening tempered proof glass door with left 	
	
	 and right metal frame slotted, single point handled locking             
	
	 F06= Single opening tempered proof glass door with 	
	
	 complete metal frame slotted, single point handled locking
	
	 F07= Single opening  solid metal door, single point handled 	
	
	 locking
	
	 F08= Single opening %63 perforated door with complete 	
	
	 metal frame slotted, single point handled locking
RX	:	 Rear door options
	
	 R01= Single opening solid metal rear door with barrel 	
	
	 type, single point lock unit	 	
	
	 R02*= Single opening solid metal rear door with barrel 	
	
	 type, single point lock unit, brushed cable entry on top and 	
	
	 bottom
	
	 R03= Double opening % 63 perforated rear door with 	
	
	 complete frame, 3 point handled locking
	
	 F04= Single opening %63 perforated door with 	
	
	
	 complete metal frame slotted, single point handled locking

H

H

Front view

Front view

RX
Rear door options

R02*
300

R03

R01

F04

55

M01

Back view

Back view

Back view

Back view

H= Enclosure height

* F05 and R02 are the standard doors
43
Universal Line free standing
TECHNICAL DRAWINGS FOR 	

600x1000 - 26U/36U/42U/47U

R01
R03
F04
R02**

F05*

F06
F07
F08

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line free standing cabinets 19” 600 x 1000 mm

CKR26U6100

26U 600x1000

26

600

1000

740

1175

1309

1324

1389

CKR36U6100

36U 600x1000

36

600

1000

740

1620

1754

1769

1834

CKR42U6100

42U 600x1000

42

600

1000

740

1889

2021

2036

2101

CKR47U6100

47U 600x1000

47

600

1000

740

2110

2244

2259

2324

* F05 is the standard front door.
** R02 is the standard rear door for 26U and above.

44
TECHNICAL DRAWINGS FOR 	

600x1000 - 26U/36U/42U/47U

600

395

F05*

200

(Min 30)
150

300

878

(Min 921)
740

H

Front view
(Min 45)
106

Bottom view
1000

19”

Mounting profile
300
55

600

F06

600

H

Front view
600

F07

55

H

Front view

H

300
Back view

Side view

600

Front view

F08

1000

600

H

Top view
H= Enclosure height

Iso view
Front view
* F05 is the standard front door.

45
Universal Line free standing
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment	 	
	
EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30,  	
IEC60917 and IEC60297
Industrial environment
EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297
Statical mechanical structure load test 	
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability 	
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, 		
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and flame resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and 	
IEC60297
Transportation
ETS300019-1-2 Class2.3
Storage
ETS300019-1-1 Class1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530,  TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS
46

KEY FEATURES

Main profile (framework) has an aesthetic structure which
increases mechanical resistance, folded at an angle of 45
degrees and consisting of 6 bends for each profile. In total;
24 folds provide framework stability.  Tested to provide (x,
y, z) axis resistance that meets EN 61587-1/5.2.1 and 5.2.2
and external impact resistance that meets EN 615871/5.3.3.
Bottom and upper case have a structure which increases
resistance and strength of cabinet by mono-block bended,
welded and profile-interlocking design. Profiles are
manufactured to interlock bottom and upper case with
screws. Cable access at bottom case has a sliding type
blanking access plate that would block dust inlet.
A rubber edge on the cable access plate with sliding
structure, allows fixing of cables into the cabinet without
any damage.
Rear door is manufactured with 2 cable access parts 1 ea.
with brush on top 1 ea. on bottom for 26 U and above
sizes*.
Rear door in standard configuration is a single opening
door which is removable and lockable. For options please
see the related diagrams and technical charts on pages
33-43.
Side panels have a structure that can be opened and
removed with slam latch and key and are lockable and
removable.
Front doors are a framed glass structure which is tempered,
anti-static, secure and smoked glass (4 mm thickness)
with a decorative stripe, according to EN 12150-1:2000
standard.  Front door in standard configuration has left and
right metal frame structure with high density polyurethane
adhesive and screw. For front door options please see the
related diagrams and technical charts on pages 33-43.  
Front door can be opened to 125 degrees, removable and
lockable  with handle type locking unit.
Pagoda style vented top panel with a dedicated space of
ventilation fan module system allows easy installation of
max. 4  fans.
19”(inch) mounting angles (2ea. in front and 2ea. in rear) are
part of the cabinet interior configuration and adjustable in
depth.
Baying is possible for side by side applications without side
panels. Levelling feet are standard in shipping configuration.  
The cabinet meets
EN 61587-1, IEC 60917, IEC 60297 standards, RoHS
compliancy, Gost and TSE certified.
Cabinets are manufactured in our factory which has ISO
9001: 2008 Quality Assurance System and our responsibility
for environment with  ISO 14001:2004 Environmental
Management System.
* Please see related diagrams to define the difference of
rear door design between up to 26U and above 26U
TECHNICAL SPECIFICATIONS

Custom number
85380000 / 85381000 / 853710990019
Shipping structure
Assembled
Mounting type
Stand alone
Load carrying capacity (kg)
600
Certification on product
TSE, Gost
Surface finish
Electrostatic powder coated c/with surface treatment , 80 +/ - 5
micron paint thickness and tested according to IEC  60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11
STANDARD PRODUCT
Standard colour
RAL 7035, RAL 9005
Standard stripe colour
Orange
IP protection standard
IP20
FRONT DOOR
Shatterproof glass with left and right metal frame
Glass
4 mm thickness full-length smoked, shatterproof, tempered,
secure
Front door construction
Single door opening
Front door lock
Handle type, single point locking
Adhesive material
High density polyurethane DIN 53479, DIN 53505
Hinge system
Spring loaded
Door opening angle and swapping
125 degree, possible to swap one side to the other
SIDE PANEL
Solid metal, 1 mm left and right (2ea.)
Side panel construction
Lockable, removable c/with slam latches and lock
Side panel lock
Barrel type lock unit, single point + Slam latch (2ea)

REAR DOOR
Solid metal, 1 mm
Rear door construction
Single opening, solid metal with brushed cable entry on top and
bottom.      
Rear door lock
Barrel type lock unit, single point
Hinge system
Spring loaded
Door opening angle and swapping
125 degree, possible to swap one side to the other
TOP COVER
                   
Solid metal 1 mm
Top cover construction
Pagoda type structure provides efficient air removal   
    
FRAMEWORK                   
Top and bottom base units
Solid metal 1,5 mm
Top and bottom base units construction
Completely welded corner socket system
Uprights
Solid metal, 1,5 mm
Uprights construction
Tightly fixed into top and bottom base units 6 times folded    
          
INTERIOR PARTS     
19’’ mounting angles
Solid metal, 1,5 mm
3 times folded 600x600, 600x780 / 1 time folded for 600x1000
“U” marking available 2 ea. at rear, 2 ea. at front
Pre-configured as 19’’
Zinc plated, passivated, 8-12 micron.
Adjustable in depth
C type support rails in depth
Solid metal, 1,5 mm  
3 times folded, 2 ea. at left , 2 ea. at right up to 26U
3 ea. at left , 3 ea. at right  26U and higher
OPTIONS    
For front and rear door options, please look at pages
33-43.

For CUSTOMIZED PRODUCTS rather than
above options, please contact sales department.  

47
Universal Line JUMBO

free standing

SELECTION STEPS FOR 	

800x800

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
	 roduct range name	

+	

U height (HHU)	

+	

Width&Depth (WD)

+	

Rear door option (RX)

The product options have the below structure:
C
	 olour option (MX)	

+	

Front door option (FX)	

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U88
	
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U88 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
	
For example: CKR42U88 - M02 - F09 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U88 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page)

48
PART NUMBER DEFINITION FOR 	

800x600 - 800x800

FX

MAIN PART NUMBER STRUCTURE
	
CKR 	
- 	HHU 	- 	WD
Product
range
Universal Line

CKR

Width
&
Depth

U
height

+

HHU

+

F09*

WD

32U

F10

780

780

86

36U

CKR

Front door options

88

39U

H

H

42U
44U
47U

CKR	:  Universal Line free standing product range  
HHU	:  “U” height
WD	:  Width and depth

Front view

F11

Front view

F12***

780

R04**

780

780

						

	 OPTIONS

MX 	 - 	 FX 	 - 	 RX
Front
door
options

Colour
options

MX

+

FX

Rear
door
options

+

H

H

H

RX

M01

F09*

R04**

M02

F10

R05

F11

R06*

F12***

F12***

Front view

* F09 and R06 are the standard doors.
** R04 can be usable as front door also.
*** F12 used as rear door as well.

Front view

RX

R04**

Rear door options

R04**

R06*
55

300

H

55

MX	:	Colour options
	
	 M01= RAL 9005 black 	
M02= RAL 7035 light grey
FX	: 	Front door options
	
	 F09*= Double opening tempered proof glass door with left and 	
	
	 right metal frame slotted, two point barrel type locking
	
	 F10= Single opening tempered proof glass door with complete 	
	
	 metal frame slotted, single point handled locking
	
	 F11= Single opening solid metal door, single point handled 	
	
	 locking
	
	 F12***= Single opening %63 perforated door with complete 	
	
	 metal frame slotted, single point handled locking
	
	 R04**= Double opening %63 perfore door with complete 	
	
	 metal frame, 3 point handled locking      
RX	:	Rear door options
	
	 R06*= Double opening complete metal door with brushed cable 	
	
	 entry, barrel type single point lock unit.
	
	 R04**= Double opening %63 perforated door  with complete 	
	
	 metal frame, 3 point handled locking
	
	 R05= Single opening solid metal rear door with barrel type, 	
	
	 single point lock unit
	
	 F12***= Single opening %63 perforated door with complete 	
	
	 metal frame slotted, single point handled locking

Front view

300

Back view

R05

Back view

Back view

F12***

Back view

H= Enclosure height

49
Universal Line JUMBO
TECHNICAL DRAWINGS FOR	

800x600 - 32U/36U/39U/42U/44U/47U

F12***
R05
R04**
R06*

F09*
F10
F11
R04**
F12***

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line JUMBO cabinets 19” 780 x 600 mm

CKR32U86

32U 780x600

32

780

600

365

1422

1576

1591

1656

CKR36U86

36U 780x600

36

780

600

365

1603

1754

1769

1834

CKR39U86

39U 780x600

39

780

600

365

1735

1887

1902

1967

CKR42U86

42U 780x600

42

780

600

365

1868

2021

2036

2101

CKR44U86

44U 780x600

44

780

600

365

1960

2110

2125

2190

CKR47U86

47U 780x600

47

780

600

365

2093

2244

2259

2324

* F09 and R06 are the standard doors.
** R04 is usable as front door also.
*** F12 is usable as rear door also.

50
TECHNICAL DRAWINGS FOR 	

800x600 - 32U/36U/39U/42U/44U/47U

F09*

515

F10

780

300
478

(Min 408)
365

55

H

(Min 138)
141

200

780

(Min 50)
90

300

19”

Bottom view

Front view

Mounting profile

780

Front view

F11
780

300
55

600

H

H

H

H

Front view

F12
55

780

Front view

300

Side view

H

Back view

Front view

780

R04

55
300
600

780

H

Top view
H= Enclosure height

Iso view

Front view
* F09 is the standard door.

51
Universal Line JUMBO
TECHNICAL DRAWINGS	

800x800 - 32U/36U/39U/42U/44U/47U

F12***
R05
R04**
R06*

F09*
F10
F11
R04**
F12***

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line JUMBO cabinets 19” 780 x 780 mm

CKR32U88

32U 780x780

32

780

780

550

1422

1576

1591

1656

CKR36U88

36U 780x780

36

780

780

550

1603

1754

1769

1834

CKR39U88

39U 780x780

39

780

780

550

1735

1887

1902

1967

CKR42U88

42U 780x780

42

780

780

550

1868

2021

2036

2101

CKR44U88

44U 780x780

44

780

780

550

1960

2110

2125

2190

CKR47U88

47U 780x780

47

780

780

550

2093

2244

2259

2324

* F09 and R06 are the standard doors.
** R04 is usable as front door also
*** F12 is usable as rear door also.

52
TECHNICAL DRAWINGS FOR 	

800x800 - 42U/47U

515
300
(Min 40)
95

F10
780

(Min 720)
550

780

H

H

(Min 130)
131

658

300

85

300

F09*

Front view

19”

Bottom view

Mounting profile

Front view

F11
780

780

300
55

780

H

H

H

Front view

F12
55

780

Front view

300

Side view

Back view
H

780
Front view

R04

55

780

300

780

H

Top view
H= Enclosure height

Iso view

Front view
* F09 is the standard front door.

53
Universal Line JUMBO free standing
SELECTION STEPS FOR 	

800x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
	 roduct range name	

+	

U height (HHU)	

+	

Width&Depth (WD)

+	

Rear door option (RX)

The product options have the below structure:
C
	 olour option (MX)	

+	

Front door option (FX)	

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U8100
	
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U8100 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
	
For example: CKR42U8100 - M02 - F09 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U8100 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page)

54
PART NUMBER DEFINITION FOR 	

800x1000

FX

MAIN PART NUMBER STRUCTURE
	

CKR 	

- 	HHU 	- 	WD

Product
range
Universal Line

CKR

Front door options

Width
&
Depth

U
height

+

HHU

+

WD

H

H

Front view

						
	

780

47U

CKR	:  Universal Line product range  
HHU	:  “U” height
WD	:  Width and depth
OPTIONS

F10

780

8100

42U

CKR

F09*

F11

Front view

F12***

780

R04**

780

780

MX 	 - 	 FX 	 - 	 RX
Front
door
options

Colour
options

MX

+

FX

Rear
door
options

+

H

RX

M01

F09*

R04**

M02

F10

R05

F11

R06*

F12

H

F12***

Front view

Front view

Front view

R04**

RX

MX	:	Colour options
	
	 M01= RAL 9005 black 	
M02= RAL 7035 light grey
FX	: 	Front door options
	
	 F09*= Double opening tempered proof glass door with left and 	
	
	 right metal frame slotted, two point barrel type locking
	
	 F10= Single opening tempered proof glass door with complete 	
	
	 metal frame slotted, single point handled locking
	
	 F11= Single opening solid metal door, single point handled 	
	
	 locking
	
	 F12***= Single opening %63 perforated door with complete 	
	
	 metal frame slotted, single point handled locking
	
	 R04**= Double opening %63 perforated door with complete 	
	
	 metal frame, 3 point handled locking      
RX	:	Rear door options
	
	 R05= Single opening solid metal rear door with barrel type, 	
	
	 single point lock unit
	
	 R04**= Double opening %63 perforated door  with complete 	
	
	 metal frame, 3 point handled locking
	
	 R06*= Double opening complete metal door with brushed cable 	
	
	 entry, barrel type single point lock unit.
	
	 F12***= Single opening %63 perforated door with complete 	
	
	 metal frame slotted, single point handled locking

Rear door options

* F09 and R06 are the standard doors
** R04 is usable as front door also.
*** F12 is usable as rear door also.

R04**

R06*
55

300

55

H

300

Back view

R05

Back view

Back view

F12***

Back view

H= Enclosure height

55
Universal Line JUMBO
TECHNICAL DRAWINGS FOR	

800x1000 - 42U/47U

F12***
R05
R04**
R06*

F09*
F10
F11
R04**
F12***

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

Universal Line JUMBO cabinets 19” 780 x 1000 mm

CKR42U8100

42U 780X1000

42

780

1000

740

1889

2021

2036

2101

CKR47U8100

47U 780X1000

47

780

1000

740

2110

2244

2259

2324

* F09 and R06 are the standard doors.
** R04 is usable as front door also.
*** F12 is usable as rear door also.

56
TECHNICAL DRAWINGS FOR 	

800x1000 - 42U/47U

515
300
(Min 26)
120

F10

780

780

(Min 852)
740
(Min 118)
136

878

300

85

300

F09*

Bottom view

H

H

Front view

19”

Mounting profile

Front view

F11
780

780

1000

55

300

H

H

H

Front view

55

F12
780

300

Front view

Side view

Back view

H

780
Front view

R04
780

1000

300

55

H

Top view
H= Enclosure height

Iso view

Front view
* F09 is the standard front door.

57
Universal Line JUMBO
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment	 	
	
EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30,  	
IEC60917 and IEC60297
Industrial environment
EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297
Statical mechanical structure load test 	
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability 	
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, 		
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and flame resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and 	
IEC60297
Transportation
ETS300019-1-2 Class2.3
Storage
ETS300019-1-1 Class1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530,  TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS
58

KEY FEATURES

Main profile (framework) has an aesthetic structure which
increases mechanical resistance, folded at an angle of 45
degrees and consisting of 6 bends for each profile. In total;
24 folds provide framework stability.Tested to provide (x, y,
z) axis resistance that meets EN 61587-1 /  5.2.1 and 5.2.2,
and external impact resistance that meets
EN 61587-1 / 5.3.3.
Bottom and upper case have a structure to increase
resistance and strength of cabinet by mono block bended,
welded and profile-interlocking design.  Profiles  are
manufactured to interlock bottom and upper case with
screws.The bottom case providing cable access is fitted
with a sliding blanking access plate to prevent dust.
A rubber edge on the cable access plate and sliding
structure, allows cables to be placed into the cabinet and
fixed inside with no damage.  Additionally both on top and
bottom, there are brushed cable entry plates for mass
cabling needs.
Rear door is manufactured with 2 cable access part top/
bottom with brush.
Rear door in standard configuration is a double opening
door which is removable and lockable. For options please
see the related diagrams and technical charts in pages 4955.
Side panels have a structure that can be opened and
removed with slam latch and key and are lockable and
removable.
Front doors are a framed glass structure which is tempered,
anti-static, secure and smoked glass (4 mm thickness)
with a decorative stripe, according to EN 12150-1:2000
standard. Front door in standard configuration has left and
right metal frame structure with high density polyurethane
adhesive and screw and double opening.
For options please see the related diagrams and technical
charts in pages 49-55.  
Front door is a double openning door which can be opened
to 125 degrees, removable and lockable with handle type
locking unit.
Pagoda style vented top panel with a dedicated space of
ventilation fan module system allows easy installation of
max. 4 fans.
19”(inch) mounting angles (2 ea. in front and 2 ea. in rear)  
are part of the cabinet interior configuration and adjustable
in depth.
Baying is possible for side by side applications without side
panels.. Levelling feet are standard in shipping configuration.
The cabinet meets EN 61587-1, IEC 60917, IEC 60297
standards, RoHS compliancy, Gost and  TSE certified.
Cabinets are manufactured in our factory which has
ISO 9001: 2008 Quality Assurance System and our
responsibility for enviroment with ISO 14001: 2004
Environmental Management System.
TECHNICAL SPECIFICATIONS

Custom number
85380000 / 85381000 / 853710990019
Shipping structure
Assembled
Mounting type
Stand alone
Load carrying capacity (kg)
600
Certification on product
TSE, Gost
Surface finish
Electrostatic powder coated c/with surface treatment , 80 +/ - 5
micron paint thickness and tested according to IEC  60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11
STANDARD PRODUCT
Standard colour
RAL 7035, RAL 9005
Standard stripe colour
Orange
Baying
Possible with baying kit for side by side applications without side
panels
IP protection standard
IP20
FRONT DOOR
Shatterproof glass with left and right metal frame
Glass
4 mm thickness full-length smoked, shatterproof, tempered,
secure
Front door construction
Double opening door
Front door lock
2 point locking barrel type
Adhesive material
High density polyurethane DIN 53479, DIN 53505
Hinge system
Spring loaded
Door opening angle and swapping
125 degree
SIDE PANEL
Solid metal, 1 mm left and right (2 ea.)
Side panel construction
Lockable, removable c/with slam latches and lock
Side panel lock
Barrel type lock unit, single point + Slam latch (2 ea)

REAR DOOR
Solid metal, 1 mm
Rear door construction
Double door opening,  lockable, removable       
Rear door lock
Barrel type lock unit, single point
Hinge system
Spring loaded
Door opening angle and swapping
125 degree
TOP COVER
                   
Solid metal 1,2 mm
Top cover construction
Pagoda type, allows efficient air removal   
    
FRAMEWORK                   
Top and bottom base units
Solid metal 1,5 mm
Top and bottom base units construction
Completely welded corner socket system
Uprights
Solid metal, 1,5 mm
Uprights construction
Tightly fixed into top and bottom base units 6 times folded        
      
INTERIOR PARTS     
19’’ mounting angles
Solid metal, 1,5 mm
3 times folded 800x600, 800x800 / 1 time folded for 800x1000
“U” marking available
2 ea. at rear, 2 ea. at front
Pre-configured as 19’’
Zinc plated, passivated, 8-12 micron.
Adjustable in depth
Omega type support rails in depth
Solid metal, 1,5 mm  
3 times folded
2 ea. at left , 2 ea. at right up to 26U
3 ea. at left , 3 ea. at right  26U and higher
OPTIONS    
For the front and rear door options, please look at pages
49-55.

For CUSTOMIZED PRODUCTS rather than
above options, please contact sales department.  

59
Universal Line JUMBO

Accessories

SPECIAL ACCESSORIES* FOR JUMBO

Teleskopic cable trunking
Designed to protect and hide cable bundles coming from
the ceiling. Since the height between ceiling and cabinet is
variable, it is manufactured as telescopic to fit all dimensions.
Coming complete with cover which when closed gives a
professional look.
Vertical cable management channels
(left and right)
Designed to manage large patch cable bundles in front of
the cabinet. It is installed through the height of the cabinet,
and each “U” dimension, there is a hole to pass horizontal
patch cables on vertical axis.  A spring hinged cover in front
of the vertical cable management panel integral with slam
latch.The cover protect and hide all cable bundles.  When
it is closed, it gives a professional look. Labour costs are
reduced by %20 and is a time saving system.
Vertical cable management trunking
Designed to carry large cable bundles through the vertical
axis of the cabinet. From top to bottom, it is continuous
with the height of cabinet. Bottom edge of the trunking
fits into the cabinet bottom cable entry, top edge of the
trunking fits into the cabinet top cable entry. It has holes
for cable access for horizantal axis. It is punched in a shape
to tie the cables. Since it has a sliding cover on the trunking,
cable bundles are hidden and protected.  When closed, it
offers a chic looking finish.
*See accessories for product part numbers, definitions and please contact sales department.

Professional cabling solutions
with JUMBO
Left and right cable management panels
hide and protect all networking cables as
well as providing a professional looking
finish.

Double opening rear doors provide space saving
between cabinet and wall.

60
UNIVERSAL LINE JUMBO FEATURES

Perforated, vented  
Pagoda-style top
providing maximum
protection against dust

Front door with
integrated locking
mechanism for
added security.

Side panel comes with
snap closures and locks
providing security, whilst
allowing four-way access
to the equipment.

Sliding access panel on
the bottom for cable
entry and a brush entry
on the rear panel that
can be positioned on the
top or bottom

61
Universal Line PCcase free standing
	

600x800 - 36U

STANDARD DIMENSIONS:
Height: 36U
Width: 600 mm
Depth:  780 mm

STANDARDS:
ISO 9001: 2008 Quality Management Systems
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for  
electronic equipments)
Overall cabinet dimensions to IEC 297-2

COLOUR:
RAL 9005 black
RAL 7035 light grey

• 19”
•	 FITS YOUR DECOR AND ENVIRONMENT
•	 SECURE AND STURDY
•	 EASY TO MAINTAIN AND LARGE INNER 	 	
	 VOLUME
•	 DUST PROOF
•	 AIR CIRCULATION WITH VENTED FILTERS

62

	

PCcase is ideal for office, factory, workshop, storage,
store, gas stations and laboratories etc. as server
housing. It protects your servers and devices against
dust, humidity, hot/cold air but most important that
against unauthorized peoples. Servers, all kind of PC’s,
monitors, keyboards, UPS’s, switches and networking
products can easily be placed in it.
Its agronomy provides the keyboards at hands level and
monitor is at eye level.
600x800 - 36U

FEATURES
PCccase cabinets match all features defined for
Universal Line as main construction.
It has 3 sections;
1st compartment: Screen section
11U space covered, (not 19’’, equipped with a fixed
shelf which should be base for the screen unit).
2nd Compartment: Keyboard section
3U space covered (not 19’’, equipped with a specific
sliding shelf integrated with mouse housing and
platform).
3rd Compartment: Device section
19” 22U usable (19’’, 22U rail allowing use of all
standard accessories to mount all kind of devices
printers, UPS, server or any LAN/WAN devices...)

All compartments are lockable.
Both side doors are lockable, removable, and
openable.
Side doors have filtered and vented air circulation
trays that allow air circulation or air entry.
It is possible to use together with cooling fans which
also has filtered and vented tray on top that allow
air circulation.
Bottom section has two door options:
Glass door or solid metal door.

63
Universal Line PCcase
TECHNICAL DRAWINGS	

600x800 - 36U

Exploded view

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

36U 600x780 mm PCcase, metal door
section at bottom

Height:
vertical
mounting
profile (mm)

PCCASE36M

Depth: max
mounting
profile (mm)

36U 600x780 mm PCcase, glass door
section at bottom

Depth:
overall
(mm)

PCCASE36

64

Product
definition
(mm)

Width:
overall
(mm)

Part
number

U
Size

Universal Line PCcase cabinets 19” 600 x 780 mm

36

600

780

555

1603

1766

1781

1846
TECHNICAL DRAWINGS FOR 	

600x800 - 36U

395

600

(Min 30)
91

1746

(Min 701)
555

658

200

(Min 30)
130

300

19”

Bottom view

Mounting profile

600

780

1746

Front view with glass door
600

Front view

Side view

Back view

1746

600

780

302

350

Front view with metal door
Top view

Iso view

65
Universal Line

free standing accessories

FREQUENTLY USED ACCESSORIES SELECTION TABLE FOR Universal Line

Estap has a wide range of accessories: Fixed shelves, heavy duty fixed shelves, sliding shelves, fans, cooling units,
vertical cable managements, cable rings, organisers, trays, plinth and so on...
* See the other accessories and part number definitions on pages 173-213.

* Please state colour choice in your orders. 	

M01=RAL 9005 black and M02= RAL 7035 light grey

Frequently used accessories selection table
Universal Line /
Shelves
part numbers
Fixed shelves

Enclosure Sizes*
PCcase

600x800

600x1000

800x600

800x800

800x1000

M44SBR80 M44SBR60 M44SBR80 M44SBR100 M44SBR60 M44SBR80 M44SBR100

Heavy duty fixed shelves
Sliding shelves

600x600

-

-

-

M55SR720

M44HRK80 M44HRK60 M44HRK80

Heavy duty sliding shelves

-

-

-

-

-

-

M44HRK60 M44HRK80

M55HR720

M55SR720
-

-

-

M55HR720

Universal Line /
Fan units
part numbers

PCcase

600x600

600x800

600x1000

800x600

800x800

800x1000

2 Fan unit with on/off switch

M44HV2F

M44HV2F

M44HV2F

M44HV2F

M44HV2F

M44HV2F

M44HV2F

4 Fan unit with on/off switch

M44HV4F

M44HV4F

M44HV4F

M44HV4F

M44HV4F

M44HV4F

M44HV4F

2 Fan unit with thermostat unit

M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT

M44HV2FT

4 Fan unit with thermostat unit

M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT

M44HV4FT

Universal Line /
Cable management
part numbers
1U cable management
panel (5 rings)
Vertical cable management

Universal Line /
PDU
part numbers

Enclosure Sizes*

Enclosure Sizes*
PCcase

600x600

600x800

600x1000

800x600

E44ORG1U E44ORG1U E44ORG1U E44ORG1U E44ORG1U
-

-

-

-

800x800

800x1000

E44ORG1U

E44ORG1U

M44ORGxxU M44ORGxxU M44ORGxxU

Enclosure Sizes*
PCcase

600x600

600x800

600x1000

800x600

800x800

800x1000

6 way PDU with 1x16A
CCT breaker,1U

M446AL

M446AL

M446AL

M446AL

M446AL

M446AL

M446AL

9 way PDU with 1x16A
CCTbreaker, 2U

M449ALC

M449ALC

M449ALC

M449ALC

M449ALC

M449ALC

M449ALC

800x600

800x800

800x1000

Universal Line /
Castor
part numbers
Castor group
Fixings/ cagenut, screw, washer
(1set=20 pcs.)

66

Enclosure Sizes*
PCcase

600x600

600x800

600x1000

M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1
KFS6X15

* Please check drawing pages for cabinet sizes.

KFS6X15

KFS6X15

KFS6X15

KFS6X15

KFS6X15

M22TKGR1
KFS6X15
EUROline free standing

Reduce

%ip5e0t
sh m n

*

cost

•	 Real flatpack design
•	 Max. 10 min** for assembly
•	 Easy to carry and transport
•	 Easy to maintenance
•	 High volume capacity for large
	 cable bundles
*	 Mixed quantity and mixed size
** Measured values by Estap. It can change 	
	 according to size of the enclosure

67
EUROline free standing
600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000

EUROline free standing enclosures

22U	 26U	 32U	 36U	

42U

600 x 600*

42U

600 x 1000*

32U	 36U	

42U

800 x 800*

					

42U

800 x 1000*

			

600 x 800*

Openable, lockable,
removable side panels,
front and rear doors
• 19”
• MODULAR STRUCTURE
• READY FOR ASSEMBLY
• STURDY, RUGGED STEEL CONSTRUCTION
• REDUCE  THE SHIPMENT COST
• FLATPACK

* Please check drawing pages for cabinet sizes.

68
600x600 - 600x800 - 600x1000 - 800x800 - 800x1000

STANDARD DIMENSIONS:
Heights: 22U, 26U, 32U, 36U, 42U
Width: 600 mm
Depth: 645 mm and 825 mm

LOAD CARRYING CAPACITY: 400 kg

Heights: 42U
Width: 600 mm
Depth: 1005 mm

RAL 7035 light grey

Heights: 32U, 36U, 42U
Width: 780 mm
Depth: 825 mm
Height: 42U
Width: 780 mm
Depth: 1005 mm

COLOUR:
RAL 9005 black

STANDARDS:
ISO 9001: 2008 Quality Management Systems
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for  
electronic equipment)
Overall cabinet dimensions for IEC 297-2

KEY FEATURES
• High quality production
• Aesthetic look
• Sturdy, rugged steel construction
• Openable, lockable, removable side panels, front and rear
doors.
• Secure, tempered front door,  with left&right metal frames,
and handle type lock.
• Easy to maintain, high volume capacity for large cable bundles.
• Upper case is suitable for fan units and brushed cable entry.
• Welded corners and sturdy construction.
• Bottom case is completely open for large cable entries.
Bottom plate with sliding type Estap standard cable entry, can
be used to close case.
• Rugged steel for 19” mounting angles
• Reduce shipment costs %50*
• Easy to transport
• Strong protection against transport damages
• Easy to assemble
• After mounting, cardboard packaging and wooden pallets
may be retained and reused for future shipments.
* Mixed quantity and mixed size

69
EUROline free standing
SELECTION STEPS FOR 	

600x600 - 600x800

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and
‘’Options’’ sections.
The below example explains how to select the right options.
The product part number has the below structure:
P
	 roduct range name	

+	

U height (HHU)	

+	

Width&Depth (WD)

+	

Rear door option (RX)

The product options have the below structure:
C
	 olour option (MX)	

+	

Front door option (FX)	

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: EU42U68
	
Step 2
Please choose the colour from the table and place it after the part number.
For example: EU42U68 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
	
For example: EU42U68 - M02 - F18 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: EU42U68 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page)

70
PART NUMBER DEFINITION 	

600x600 - 600x800

FX

MAIN PART NUMBER STRUCTURE
	

EU 	

Front door option

- 	 HU 	- 	WD
H

Product
range
EUROline

EU

Width
&
depth

U
height

+

HHU
22U

+

F18

WD
66
68

26U

EU

600

32U
36U
42U

EU	:  EUROline free standing product range  
HHU	:  “U” height
WD	:  Width and depth

H

OPTIONS
	

MX 	 - 	 FX	 - 	 RX
Front
door
option

Colour

MX
M01

+

FX
F18

Rear
door
option

+

RX

Front view

R10

RX

M02

Rear door option
600

R10

MX	: Colour options
		 RAL 9005 black
M01=
		 RAL 7035 light grey
M02=
FX	:  Front door option
		Single opening shatter proof glass door with left 	
F18=
	
	 and right metal frame slotted, single point handled 	
	
	 locking            
H

RX	: Rear door option
		Single opening solid metal rear door with 	 	
R10=
	
	 barrel type lock unit, single point

H= Enclosure height

Back view

71
EUROline free standing
TECHNICAL DRAWINGS FOR 	

600x600 - 22U/26U/32U/36U/42U

R10

F18

*

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

EUROline free standing cabinets 19” 600 x 645 mm

EU22U66

22U 600x645

22

600

645

331,5

1070

1135

1150

1215

EU26U66

26U 600x645

26

600

645

331,5

1245

1310

1325

1370

EU32U66

32U 600x645

32

600

645

331,5

1515

1575

1590

1655

EU36U66

36U 600x645

36

600

645

331,5

1700

1755

1770

1825

EU42U66

42U 600x645

42

600

645

331,5

1960

2025

2040

2105

* Bottom cover plate is an optional accessory.

72
TECHNICAL DRAWINGS FOR 	

600x600 - 22U/26U/32U/36U/42U

F18

600

H

(Min 93,5)
155

566

(Min 455)
331,5

(Min 91,5)
153

521

19”

Bottom view*

Note: *Bottom is empty, the top of the

Front view

Mounting profile

enclosure appears

600

645

566

521

300

200

H

Bottom view*
Note: * Bottom cover plate is an optional

accessory

Side view

645

600
300

Back view

72

Front view

Top view
H= Enclosure height

Iso view

73
EUROline free standing
TECHNICAL DRAWINGS FOR 	

600x800 - 22U/26U/32U/36U/42U

R10

F18

*
Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

EUROline free standing cabinets 19” 600 x 825 mm

EU22U68

22U 600x825

22

600

825

511,5

1070

1135

1150

1215

EU26U68

26U 600x825

26

600

825

511,5

1245

1310

1325

1395

EU32U68

32U 600x825

32

600

825

511,5

1515

1575

1590

1655

EU36U68

36U 600x825

36

600

825

511,5

1700

1755

1770

1840

EU42U68

42U 600x825

42

600

825

511,5

1960

2025

2040

2110

* The bottom cover plate is an optional accessory.

74
TECHNICAL DRAWINGS FOR 	

600x800 - 22U/26U/32U/36U/42U

521

F18

(Min 635)
511,5

746

(Min 91,5)
153

600

(Min 91,5)
153

H

19”

Bottom view*

Mounting profile

Note: * Bottom is empty, the top of the
enclosure appears

521

825

746

200

600

Front view

300
H

Bottom view*
Note: * Bottom cover plate is an optional

accessory

Side view

Front view

Back view

825

72

600
300

Top view
H= Enclosure height

Iso view

75
EUROline free standing
SELECTION STEPS FOR 	

600x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and
‘’Options’’ sections.
The below example explains how to select the right options.
The product part number has the below structure:
P
	 roduct range name	

+	

U height (HHU)	

+	

Width&Depth (WD)

+	

Rear door option (RX)

The product options have the below structure:
C
	 olour option (MX)	

+	

Front door option (FX)	

HOW TO SELECT THE OPTIONS
Step 1 - Please choose product part number.
For example: EU42U61	
Step 2 - Please choose the colour from the table and place it after the part number.
For example: EU42U61 - M02 (MX=Look at the MX colour options on the next page)
Step 3 - Please choose the front door from the table and place it after MX colour.	
For example: EU42U61 - M02 - F18 (FX= Look at the FX front door options on the next page)
Step 4 - Please choose the rear door from the table and place it after FX front door option.
For example: EU42U61 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page)

76
PART NUMBER DEFINITION FOR 	

600x1000

FX

MAIN PART NUMBER STRUCTURE
	

Front door options

EU 	 - 	HHU 	- 	WD
Product
range
EUROline

EU

Width
&
depth

U
height

+

EU

HHU

+

WD

600

61

42U

EU	:  EUROline free standing product range  
HHU	:  “U” height
WD	:  Width and depth

F21

600

F18*

H

H

OPTIONS
	 MX	 - 	 FX 	 - 	 RX
Front
door
options

Colour
options

MX

+

FX

Front view

Front view

Rear
door
options

+

RX

M01

F18*

R10**

M02

F21

R07

RX
RX
Rear door options
Rear door options

MX	:  Colour options
		 RAL 9005 black
M01=
		 RAL 7035 light grey
M02=
FX	:  Front door options
		 Single opening shatter proof glass door with  	
F18*=
	
	 left and right metal frame slotted, single point handled 	
	
	 locking
		Single opening %63 perforated front door,
F21=
	
	 full slotted frame, single point handled locking
RX	: Rear door options
		 Single opening solid metal rear door  with  	
R10**=
	
	 barrel  type lock unit, single point locking
		 Double opening complete framed % 63 		
R07=
	
	 perforated front door, 3 point handled locking

600

R10**

600

H

Back view

R07

H

Back view

H= Enclosure height
H= Enclosure height
* F18 is the standard front door.
** R10 is the standard rear door.

77
EUROline free standing
TECHNICAL DRAWINGS FOR 	

600x1000 - 42U

R07

R10**

F21
F18*

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

EUROline free standing cabinets 19” 600 x 1005 mm

EU42U61

42U 600x1005

42

600

1005

702,5

1960

2025

2040

2110

* F18 is the standard front door.
** R10 is the standard rear door.

78
TECHNICAL DRAWINGS FOR 	

600x1000 - 42U

600

522

(Min 85,5)
147

522

(Min 825,5)
702,50

926

463

(Min 86,5)
148

F18*

Bottom view*
Note: *Bottom is empty, the top of the
enclosure appears

H

19”
Mounting profile

600

Front view

1005

600

H

F21

H

Side view

Front view

Back view

Front view

600

1005

72

300

Top view

Iso view

H= Enclosure height
* F18 is the standard front door.

79
EUROline free standing
SELECTION STEPS FOR 	

800x800 - 800x1000

STEPS TO SELECT RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section on the catalogue, has a ‘’Main part numbers’’ and
‘’Options’’ sections.
The below example explains how to select the right options.
The product part number has the below structure:
P
	 roduct range name	

+	

U height (HHU)	

+	

Width&Depth (WD)

+	

Rear door option (RX)

The product options have the below structure:
C
	 olour option (MX)	

+	

Front door option (FX)	

HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: EU42U88 or EU42U81
Step 2
Please choose the colour from the table and place it after the part number.
For example: EU42U88 - M02 (MX=Look at the MX colour options on the next page) or
	
EU42U81 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: EU42U88 - M02 - F20 (FX= Look at the FX front door options on the next page) or
	
EU42U81 - M02 - F20 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: EU42U88 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page) or
	
EU42U81 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page)

80
PART NUMBER DEFINITION 	

800x800 - 800x1000

FX

MAIN PART NUMBER STRUCTURE
	
EU	 - 	HHU	 - 	WD
Product
range
EUROline

EU

Width
&
depth

U
height

+

HHU
32U

Front door options

+

780

H

H

81

EU	:  EUROline free standing product range  
HHU	:  “U” height
WD	:  Width and depth

Front view

Front view

RX

				
OPTIONS

	

MX 	 - 	 FX 	 - 	

Rear door options

RX

780

Front
door
options

Colour
options

MX

+

FX

F19*

88

42U
42U

780

WD

36U

EU

F20**

R12***

Rear
door
options

+

RX

M01

F20**

R12***

M02

F19*

R11

R08*

R08*

H

F19*

MX	:  Colour options
		 RAL 9005 black
M01=
		 RAL 7035 light grey
M02=

Back view
780

FX	:  Front door options
		 Double opening shatter proof glass door with 	 	
F20**=
	
	 left and right metal frame slotted, 3 point handled 	
	
	
	 locking  
		Single opening %63 perforated front door,
F19=
	
	 full slotted frame, single point handled locking
		 Double opening complete framed %63 	 	
R08*=
	
	
	 perforated front door, 3 point handled locking         
RX	: Rear door options
		 Double opening metal rear door with 	 	
R12***=
	
	 3 point handled locking
		Single opening solid metal rear door with 	 	
R11=
	
	 barrel type lock unit, single point lock unit
		 Double opening complete framed %63 	 	
R08*=
	
	 perforated front door,  3 point handled locking
	
	 F19*= Single opening %63 perforated front door,
	
	 full slotted frame, single point handled locking

H

Back view

R08*

780

	
	
H

	

H= Enclosure height
* R08 and F19 can be used as both front and rear door.
** F20 is the standard front door.
*** R12 is the standard rear door.

R11

Back view

81
EUROline free standing
TECHNICAL DRAWINGS FOR 	

800x800 - 32U/36U/42U

F19**
R08**
R11
R12****

F19**
F20***
R08**

*

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

EUROline free standing cabinets 19” 780 x 825 mm

EU32U88

32U 780x825

32

780

825

511,5

1515

1525

1540

1655

EU36U88

36U 780x825

36

780

825

511,5

1630

1755

1770

1840

EU42U88

42U 780x825

42

780

825

511,5

1960

2025

2040

2110

* The bottom cover plate is optional.
** R08 and F19 can be used as both front and door rear door.
*** F20 is the standard front door.
**** R12 is the standard rear door.	

82
TECHNICAL DRAWINGS FOR 	

800x800 - 32U/36U/42U

780

F20*

701

(Min 725)
511,5

H

(Min 47,5)
154

776

746

(Min 44,5)
151

513

19”

Bottom view*

Mounting profile

Note: *Bottom is empty, the top of the

Front view

enclosure appears

780

701

825

780

F19

200

300

746

H

H

Bottom view

Note: Bottom cover plate is an optional

accessory

Front view

Side view

Back view

Front view

780

Top view
H= Enclosure height

747

300

300

R08

72

702

H

Iso view

Front view
* F20 is the standard front door.

83
EUROline free standing
TECHNICAL DRAWINGS FOR 	

800x1000 - 42U

F19**
R08**
R12****
R11

F19**

F20***
R08**

*

Exploded view

Part
number

Product
definition
(mm)

U
Size

Width:
overall
(mm)

Depth:
overall
(mm)

Depth: max
mounting
profile (mm)

Height:
vertical
mounting
profile (mm)

Height:
without
levelling feet
(mm)

Height:
with
levelling feet
(mm)

Height:
with casters
(mm)

EUROline free standing cabinets 19” 780 x 1005 mm

EU42U81

42U 780x1005

42

780

1005

704,5

1960

2025

2040

2110

* The bottom cover plate is optional.
** R08 and F19 can be used as both front and door rear door.
*** F20 is the standard front door.
**** R12 is the standard rear door.	

84
TECHNICAL DRAWINGS FOR 	

800x1000 - 42U

701
513

780

H

(Min 40)
146,5

926

(Min 784,5)
704,50

(Min 40)
146,5

F20*

Bottom view*
Note: *Bottom is empty, the top of the
enclosure appears

19”

Mounting profile

Front view

1005

780

780

F19

H
H

Front view

Side view

Back view

780
702

Front view

780

R08

72

300

H

300

927

1005

55

H= Enclosure height

Top view

Iso view

Front view
* F20 is the standard front door.

85
EUROline free standing
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment			
EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, 	
IEC60917 and IEC60297
Industrial environment 	
EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297
Statical mechanical structure load test 	
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability 	
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, 	
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and Flame Resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree
IP00.When bottom cover plate is used, it becomes IP20
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and	
IEC60297
Transportation
ETS300019-1-2 Class2.3
Storage
ETS300019-1-1 Class1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530,  TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS

86

KEY FEATURES
Main profile vertical (framework) has a structure which
increases mechanical resistance with aesthetic appearance and
a specially closed profile system of 30x30 mm from automation
industry. Folded with an angle of 90 degree:The corner joints
are welded with 4 fold connection brackets.The main profile
vertical (framework) connects to top and bottom case with
heavy duty 5 fold bended profile system.  A total of 20 folds
provide stability for the top and bottom case.  Additionally,
at 600x1000 and 800x1000 mm sizes a 5 fold (bend surface)
bracket system provides additional stability, providing a 25 fold
(bent surface) design criteria for the frame. Manufactured and
tested to provide axial (x, y, z) resistance that meets EN 61587-1
/  5.2.1 and 5.2.2, and external impact resistance that meets EN
61587-1 / 5.3.3.
Using a folded profile system for structure, the bottom and
upper case are connected to the vertical profile system using
heavy duty screws which provide modularity. Bottom case if
fully open for large cable bundles to be placed; if required to
close the bottom, a cover plate can be purchased as an optional
accessory with sliding type edged cable entry panel.
The rubber edge on the cable access plate and sliding structure,
allows cables to be placed into the cabinet and fixed inside with
no damage.
For W=600 mm enclosure rear door is single solid metal,
removable and lockable. Integral locking is single point barrel
type locking system. For W=800 mm enclosure rear door in
double opening, complete metal and 3 point handled locking.
For options please see the related diagrams and technical charts
On pages 71-77-81.
Rear doors can be opened up to 220 degrees.
Side panels have a structure that can be opened and removed
with a key and are lockable and removable. Side panels are
consist of 2 piece side panels on each side for D=1000 mm
range due to easy handling and maintanence needs. Original
functional side panel is lockable and removable as mentioned
above; the smaller side panel is fixed from inner side with
screws.Within this engineering construction the original
functional side panel becomes easy to carry while installation
and maintanance is in process.
Front doors are single opening, left and right metal framed glass
door,  single point handled locking on the W=600 mm series,
front doors are double opening, left and right metal framed glass
door, 3 point handled locking on the W=800 mm series, front
door can be opened up to 220 degrees, removable and lockable
with handle type locking unit. For options please see the related
diagrams and technical charts on pages 71-77-81.
Vented top panel housing with a dedicated space for ventilation,
fan module system allows easy installation of max. 4 fans from
top.
19”(inch) mounting angles (2 ea. in front and 2 ea. in rear) are
part of cabinets interior configuration and adjustable in depth.
Baying is possible for side by side applications. Levelling feet are
standard in shipping configuration.The cabinet meets
EN 61587-1, IEC 60917, IEC 60297 standards RoHS compliancy,
Gost and TSE certified.
Cabinets are manufactured in our factory which has
ISO 9001: 2008 Quality Assurance System and our responsibility
for environment with ISO 14001:2004 Environmental
Management System.
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages

Weitere ähnliche Inhalte

Ähnlich wie Estap 2012-2013 catalogue all pages

leaflet_19_racks_and_accessories.pdf
leaflet_19_racks_and_accessories.pdfleaflet_19_racks_and_accessories.pdf
leaflet_19_racks_and_accessories.pdfMohamedshabana38
 
PASSIVE NETWORKING EQUIPMENTS - NETCAB.pdf
PASSIVE NETWORKING EQUIPMENTS - NETCAB.pdfPASSIVE NETWORKING EQUIPMENTS - NETCAB.pdf
PASSIVE NETWORKING EQUIPMENTS - NETCAB.pdfPCTLAutomation
 
Sapa energy product line
Sapa energy product lineSapa energy product line
Sapa energy product lineprofilalouminio
 
Cleanroom catalog 2015 - reduced
Cleanroom catalog   2015 - reducedCleanroom catalog   2015 - reduced
Cleanroom catalog 2015 - reducedSusan Szewczuk
 
Adjustable polypropylene pedestal
Adjustable polypropylene pedestalAdjustable polypropylene pedestal
Adjustable polypropylene pedestalNitishJambhurkar
 
Innovations 2015
Innovations 2015Innovations 2015
Innovations 2015Eeu SC
 
Innovations 2015
Innovations  2015Innovations  2015
Innovations 2015Eeu SC
 
Siemens Sivacon S8 Info
Siemens Sivacon S8 InfoSiemens Sivacon S8 Info
Siemens Sivacon S8 Infonor52097
 
Roller shutter Supergradhermetic - Gradhermetic
Roller shutter Supergradhermetic - GradhermeticRoller shutter Supergradhermetic - Gradhermetic
Roller shutter Supergradhermetic - GradhermeticGerardRocaSimn
 
Mayline Technology Furniture
Mayline   Technology FurnitureMayline   Technology Furniture
Mayline Technology FurnitureJoshua Long
 
Nassau Industrial Doors Ltd
Nassau Industrial Doors LtdNassau Industrial Doors Ltd
Nassau Industrial Doors Ltdgerttcow
 
Ls catalog thiet bi dien tm lvs_catalog_e_0901
Ls catalog thiet bi dien tm lvs_catalog_e_0901Ls catalog thiet bi dien tm lvs_catalog_e_0901
Ls catalog thiet bi dien tm lvs_catalog_e_0901Dien Ha The
 
Ls catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vn
Ls catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vnLs catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vn
Ls catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vnDien Ha The
 
MaperGlas_CTU_Telescopic_Enclosures
MaperGlas_CTU_Telescopic_EnclosuresMaperGlas_CTU_Telescopic_Enclosures
MaperGlas_CTU_Telescopic_EnclosuresMAPERGLAS
 

Ähnlich wie Estap 2012-2013 catalogue all pages (20)

leaflet_19_racks_and_accessories.pdf
leaflet_19_racks_and_accessories.pdfleaflet_19_racks_and_accessories.pdf
leaflet_19_racks_and_accessories.pdf
 
evoline-en Rack 42U.pdf
evoline-en Rack 42U.pdfevoline-en Rack 42U.pdf
evoline-en Rack 42U.pdf
 
PASSIVE NETWORKING EQUIPMENTS - NETCAB.pdf
PASSIVE NETWORKING EQUIPMENTS - NETCAB.pdfPASSIVE NETWORKING EQUIPMENTS - NETCAB.pdf
PASSIVE NETWORKING EQUIPMENTS - NETCAB.pdf
 
Sapa energy product line
Sapa energy product lineSapa energy product line
Sapa energy product line
 
UNITILE, DATA CENTER
UNITILE, DATA CENTER UNITILE, DATA CENTER
UNITILE, DATA CENTER
 
Cleanroom catalog 2015 - reduced
Cleanroom catalog   2015 - reducedCleanroom catalog   2015 - reduced
Cleanroom catalog 2015 - reduced
 
Versa Pod 2010
Versa Pod 2010Versa Pod 2010
Versa Pod 2010
 
Adjustable polypropylene pedestal
Adjustable polypropylene pedestalAdjustable polypropylene pedestal
Adjustable polypropylene pedestal
 
Innovations 2015
Innovations 2015Innovations 2015
Innovations 2015
 
Innovations 2015
Innovations  2015Innovations  2015
Innovations 2015
 
Air curtains 2015 catalogue - Airtecnics Full range
Air curtains 2015 catalogue - Airtecnics Full rangeAir curtains 2015 catalogue - Airtecnics Full range
Air curtains 2015 catalogue - Airtecnics Full range
 
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
 
Siemens Sivacon S8 Info
Siemens Sivacon S8 InfoSiemens Sivacon S8 Info
Siemens Sivacon S8 Info
 
Roller shutter Supergradhermetic - Gradhermetic
Roller shutter Supergradhermetic - GradhermeticRoller shutter Supergradhermetic - Gradhermetic
Roller shutter Supergradhermetic - Gradhermetic
 
Mayline Technology Furniture
Mayline   Technology FurnitureMayline   Technology Furniture
Mayline Technology Furniture
 
Nassau Industrial Doors Ltd
Nassau Industrial Doors LtdNassau Industrial Doors Ltd
Nassau Industrial Doors Ltd
 
WGS-803 Industrial Wall-mount Switch
WGS-803 Industrial Wall-mount Switch WGS-803 Industrial Wall-mount Switch
WGS-803 Industrial Wall-mount Switch
 
Ls catalog thiet bi dien tm lvs_catalog_e_0901
Ls catalog thiet bi dien tm lvs_catalog_e_0901Ls catalog thiet bi dien tm lvs_catalog_e_0901
Ls catalog thiet bi dien tm lvs_catalog_e_0901
 
Ls catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vn
Ls catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vnLs catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vn
Ls catalog thiet bi dien tm lvs_catalog_e_0901_dienhathe.vn
 
MaperGlas_CTU_Telescopic_Enclosures
MaperGlas_CTU_Telescopic_EnclosuresMaperGlas_CTU_Telescopic_Enclosures
MaperGlas_CTU_Telescopic_Enclosures
 

Kürzlich hochgeladen

AI You Can Trust - Ensuring Success with Data Integrity Webinar
AI You Can Trust - Ensuring Success with Data Integrity WebinarAI You Can Trust - Ensuring Success with Data Integrity Webinar
AI You Can Trust - Ensuring Success with Data Integrity WebinarPrecisely
 
Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...
Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...
Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...Will Schroeder
 
OpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability AdventureOpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability AdventureEric D. Schabell
 
Salesforce Miami User Group Event - 1st Quarter 2024
Salesforce Miami User Group Event - 1st Quarter 2024Salesforce Miami User Group Event - 1st Quarter 2024
Salesforce Miami User Group Event - 1st Quarter 2024SkyPlanner
 
UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8DianaGray10
 
Linked Data in Production: Moving Beyond Ontologies
Linked Data in Production: Moving Beyond OntologiesLinked Data in Production: Moving Beyond Ontologies
Linked Data in Production: Moving Beyond OntologiesDavid Newbury
 
COMPUTER 10 Lesson 8 - Building a Website
COMPUTER 10 Lesson 8 - Building a WebsiteCOMPUTER 10 Lesson 8 - Building a Website
COMPUTER 10 Lesson 8 - Building a Websitedgelyza
 
AI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just MinutesAI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just MinutesMd Hossain Ali
 
IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019
IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019
IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019IES VE
 
Empowering Africa's Next Generation: The AI Leadership Blueprint
Empowering Africa's Next Generation: The AI Leadership BlueprintEmpowering Africa's Next Generation: The AI Leadership Blueprint
Empowering Africa's Next Generation: The AI Leadership BlueprintMahmoud Rabie
 
Crea il tuo assistente AI con lo Stregatto (open source python framework)
Crea il tuo assistente AI con lo Stregatto (open source python framework)Crea il tuo assistente AI con lo Stregatto (open source python framework)
Crea il tuo assistente AI con lo Stregatto (open source python framework)Commit University
 
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDEADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDELiveplex
 
Cybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptxCybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptxGDSC PJATK
 
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPAAnypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPAshyamraj55
 
20230202 - Introduction to tis-py
20230202 - Introduction to tis-py20230202 - Introduction to tis-py
20230202 - Introduction to tis-pyJamie (Taka) Wang
 
Building AI-Driven Apps Using Semantic Kernel.pptx
Building AI-Driven Apps Using Semantic Kernel.pptxBuilding AI-Driven Apps Using Semantic Kernel.pptx
Building AI-Driven Apps Using Semantic Kernel.pptxUdaiappa Ramachandran
 
Computer 10: Lesson 10 - Online Crimes and Hazards
Computer 10: Lesson 10 - Online Crimes and HazardsComputer 10: Lesson 10 - Online Crimes and Hazards
Computer 10: Lesson 10 - Online Crimes and HazardsSeth Reyes
 
Nanopower In Semiconductor Industry.pdf
Nanopower  In Semiconductor Industry.pdfNanopower  In Semiconductor Industry.pdf
Nanopower In Semiconductor Industry.pdfPedro Manuel
 
How Accurate are Carbon Emissions Projections?
How Accurate are Carbon Emissions Projections?How Accurate are Carbon Emissions Projections?
How Accurate are Carbon Emissions Projections?IES VE
 
UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...
UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...
UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...UbiTrack UK
 

Kürzlich hochgeladen (20)

AI You Can Trust - Ensuring Success with Data Integrity Webinar
AI You Can Trust - Ensuring Success with Data Integrity WebinarAI You Can Trust - Ensuring Success with Data Integrity Webinar
AI You Can Trust - Ensuring Success with Data Integrity Webinar
 
Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...
Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...
Apres-Cyber - The Data Dilemma: Bridging Offensive Operations and Machine Lea...
 
OpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability AdventureOpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability Adventure
 
Salesforce Miami User Group Event - 1st Quarter 2024
Salesforce Miami User Group Event - 1st Quarter 2024Salesforce Miami User Group Event - 1st Quarter 2024
Salesforce Miami User Group Event - 1st Quarter 2024
 
UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8
 
Linked Data in Production: Moving Beyond Ontologies
Linked Data in Production: Moving Beyond OntologiesLinked Data in Production: Moving Beyond Ontologies
Linked Data in Production: Moving Beyond Ontologies
 
COMPUTER 10 Lesson 8 - Building a Website
COMPUTER 10 Lesson 8 - Building a WebsiteCOMPUTER 10 Lesson 8 - Building a Website
COMPUTER 10 Lesson 8 - Building a Website
 
AI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just MinutesAI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just Minutes
 
IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019
IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019
IESVE Software for Florida Code Compliance Using ASHRAE 90.1-2019
 
Empowering Africa's Next Generation: The AI Leadership Blueprint
Empowering Africa's Next Generation: The AI Leadership BlueprintEmpowering Africa's Next Generation: The AI Leadership Blueprint
Empowering Africa's Next Generation: The AI Leadership Blueprint
 
Crea il tuo assistente AI con lo Stregatto (open source python framework)
Crea il tuo assistente AI con lo Stregatto (open source python framework)Crea il tuo assistente AI con lo Stregatto (open source python framework)
Crea il tuo assistente AI con lo Stregatto (open source python framework)
 
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDEADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
 
Cybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptxCybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptx
 
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPAAnypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPA
 
20230202 - Introduction to tis-py
20230202 - Introduction to tis-py20230202 - Introduction to tis-py
20230202 - Introduction to tis-py
 
Building AI-Driven Apps Using Semantic Kernel.pptx
Building AI-Driven Apps Using Semantic Kernel.pptxBuilding AI-Driven Apps Using Semantic Kernel.pptx
Building AI-Driven Apps Using Semantic Kernel.pptx
 
Computer 10: Lesson 10 - Online Crimes and Hazards
Computer 10: Lesson 10 - Online Crimes and HazardsComputer 10: Lesson 10 - Online Crimes and Hazards
Computer 10: Lesson 10 - Online Crimes and Hazards
 
Nanopower In Semiconductor Industry.pdf
Nanopower  In Semiconductor Industry.pdfNanopower  In Semiconductor Industry.pdf
Nanopower In Semiconductor Industry.pdf
 
How Accurate are Carbon Emissions Projections?
How Accurate are Carbon Emissions Projections?How Accurate are Carbon Emissions Projections?
How Accurate are Carbon Emissions Projections?
 
UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...
UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...
UWB Technology for Enhanced Indoor and Outdoor Positioning in Physiological M...
 

Estap 2012-2013 catalogue all pages

  • 2. ESTAP HEAD OFFICE - SANCAKTEPE / İSTANBUL ESTAP FACTORY - ESKİŞEHİR 40.000 m2 open area, 20.000 m2 closed area. Making production with 400 employess.
  • 3. CONTENTS FREE STANDING CABINETS ServerMAX 600x1000 - 800x1000 3-22 DCMax Datacenter solutions 23-26 Universal Line 600x600 - 600x800 - 600x1000 Universal Line JUMBO 800x600 - 800x800 - 800x1000 Universal Line PCcase 600x800 27-66 EUROline 8 00x800 - 800x1000 600x600 - 600x800 - 600x1000 67-88 ECOline 8 00x800 - 800x1000 600x600 - 600x800 - 600x1000 89-108 RELAYrack Single frame, D=600 Double frame, D= 800, D=1000 109-116 PROline 600x450 - 600x560 - 600x(160+450) 117-130 PROline Residential 600x150 - 600x300 131-136 EUROline wall mounting 600x450 - 600x600 137-146 ECOline wall mounting 600x450 - 600x600 147-156 WALL MOUNTING CABINETS SOHOline wall mounting 520x300 - 520x400 292x300 (10”) SOHO Slimline 157-166 167-168 OTHER PRODUCTS Fiber Optic Boxes 169-171 PDU 173-174 Accessories Free standing accessories Wall mounting accessories 175-215 OUTDOOR ENCLOSURES 217-224 QUALITY CERTIFICATIONS 225 IP PROTECTION CLASS 226 NOTES 227-228
  • 4. ServerMAX free standing • Compatible with all EIA-310 compliant 19” equipment. All type of servers, brands will physically fit in ServerMAX server cabinet. • Bottom plate has an extra perforated plate to prevent insects or mice from reaching the cables. • Efficient passive air circulation • Numbered U positions facilitate easy installation of rack mounted equipment. 3
  • 5. ServerMAX free standing 600x1000 - 800x1000 ServerMAX free standing enclosure 26U 36U 42U 47U 42U 47U 600 x 1000* 800 x 1000* ServerMAX protects your technological investments • 19” • HIGH QUALITY PRODUCTS • COMPLIMENTS YOUR DECOR AND ENVIRONMENT • SECURE AND STURDY • EASY TO MAINTAIN: LARGE INNER VOLUME • HIGH SECURITY FOR UNAUTHORIZED ACCESS • STRONG PROTECTION AGAINST PHYSICAL DAMAGE • EXCELLENT PASSIVE AIR VENTILATION * Please check drawing pages for cabinet sizes. 4
  • 6. SERVERMAX FREE STANDING ENCLOSURES FOR STANDARD DIMENSIONS: Heights: 26U, 36U, 42U, 47U Width: 600 mm Depth: 1000 mm Heights: 42U, 47U Width: 780 mm Depth: 1000 mm LOAD CARRYING CAPACITY: 1000 kg 600x1000 -800x1000 COLOUR: RAL 9005 black RAL 7035 light grey STANDARDS: ISO 9001 : 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2 KEY FEATURES Adjustable mounting depth: 19” mounting angles are adjustable in depth for various mounts for adjustable depth distance, please look at drawing pages. Bottom plate: fitted with an additional plate to prevent insects/vermin. If necessary a filter may be integrated to prevent dust infiltration. Bottom plate is complete with pre-punched removable sections: when airflow comes from the floor, these sections can be removed to provide efficient airflow inside the cabinet. Reversible doors: Front and rear doors may be detached and reversed to allow the door to open from the rear of the cabinet. Side doors are split in two: Front section used to access the cabinet; additional smaller section secured inside the cabinet. If additional ventilation is necessary it can be demanded as vented. The main inner strip of this panel is designed for the housing of cables and power strips. Numbered “U” positions facilitate easy installation for rack mounted equipment. Vertical mounting rails with square holes; adjustable in depth. 5
  • 7. ServerMAX free standing 600x1000 - 800x1000 Optional plexi front door: May be used instead of vented front door. All in one: ServerMAX includes; casters, doors, ground studs, levelling feet, roof, bottom, side panels, C-rails, tilt bars, unloaded fan tray. Optimized depth: 1000 mm.Today and next generation installation of servers, for power distribution and cable management. 1000 mm is the optimum depth for comfort cabling, housing server and gaining space in data centers. Fixing to floor: ServerMAX can be easily fixed to the floor when necessary. A floor fixing kit is used for this purpose. Please see accessories for floor fixing kit. Efficient passive ventilation: New generation servers and networking products need adequate ventilation to operate efficiently. ServerMAX server cabinets provide 6 efficient passive ventilation because of its vented structure of front and rear doors. Front and rear doors have maximum perforation (%63) patterns for high-density cooling that meets or exceeds server manufacturer’s ventilation requirements. There is a fan tray on roof: Removable easily from the top.When the maintanence of fans are required, it can be reached directly from the top without touching any mounted device or servers. It is possible to attach a filter on top of the server fan unit. Generous cable access holes are provided in the roof and base. One on top, one on bottom holes are special ESTAP style cable entries; sliding type with rubber edges.
  • 8. FEATURES Quick release side doors: During installation and while conducting routine maintenance of installed equipment, it is often advantageous to remove the side panels. Quick release slam latches and locks on the side panels allow for quick and easy access. 600x1000 - 800x1000 Anti-tilt bars: As standard, ServerMAX is fitted with 2 sliding type tilt bars to make the cabinet stable in weight center. Whenever the servers are moved out, tilt bars are drawn out to counter-balance the cabinets weight center. Double opening rear doors improve access and serviceability to rear of rack mounted equipment.The split rear doors help to maximize floor space. Only 390 mm for W=780 mm cabinets of clearance is required behind the enclosure to allow for door swing. D= 200 mm extention unit: If deeper equipment is loaded into ServerMAX cabinets requiring additional depth for cable radius, cable bundles, PDU housing etc, a D=200mm extension unit may be installed to ServerMAX cabinets: the rear door is removed and reinstalled onto the extension unit. (Please see diagrams on pages 18-19) Expansion: ServerMAX enclosures can be easily expanded to create complete rows of enclosures without side panels. With a proper baying kit (please see accessories) all cabinets are bayed easily and quickly. Welded: Bottom and roof of the cabinet is completely welded and a closed structure. Sturdy and rugged, it protects against physical elements like dust, insects. Lockable doors and side panels: Front and rear doors are lockable using a 3 point locking mechanism. A handle-style locking system provides increased security to prevent unauthorized access. All doors and side panels are only accessible with a key provided by ServerMAX. Stability: Heavy duty frame design, 2 mm mounting rails, angles, heavy duty type castor group provide 1000 kg load rating. 7
  • 9. ServerMAX free standing FEATURES 600x1000 - 800x1000 Grounding: All parts are fitted with grounding studs to provide electrical continuity. Surface treatment: Fosfat coating, oil remove and passivation. Heavy duty vertical frames: Instead of 4ea. vertical profiles, ServerMAX cabinets are 6ea.(3ea.in left+3ea.in right) main vertical profiles that gives extra stability for heavy loads. Material thicknesses: Roof, bottom, vertical main frames, 1,5 mm C-rails, 19” mounting angles, profiles and all frames are 2 mm thickness. Sturdy steel construction. More C rails: Instead of 6ea. there are 8 horizontal C rails in depth for extra stability. (42U, 47U) Paint: Electrostatic powder coating. Reinforced bottom: Bottoms are reinforced with horizontal profiles in width and depth for extra stability. Rounded aesthetic monoblok front door: Front door is a heavy duty type monoblock perforated and welded structure. It’s shape is rounded in front to enhance the aesthetics. Easy to dismantle and assembly: The rigidly welded frame construction can be dismantled and assembled easily without any special tools.Thus, narrow doors, staircases and lifts are no problem. Special cable entry on top and bottom case: Bottom plate and top case have a special cable entry, completely closed, sliding type with rubber edges. Cables are entered and fixed. Housing for cabling: The cabinet itself has enough housing for vertical cable management at back. For 600x1000 cabinet, cable rings are used for cable management. For 780x1000 cabinets there are special vertical cable management panels of Ieft & right with cover plate for hiding and protecting the cables. These allow customers to easily route, manage and access large numbers of data cables even while an enclosure is loaded with rack mount equipment and bayed in a row. Power/energy distribution: Rear power distribution housing at back of the cabinet provide easy access to multiple receptacles. Vertical power distribution strips can easily be mounted in that space. This housing never interfere with equipment or takes any valuable “U” space. Providing increased accessibility to receptacles allows customers to support more power cords within the enclosure. Power strips are the length of cabinets: 26U, 36U, 42U, 47U. 8
  • 10. ADDITIONAL FEATURES FOR More Volume Width=780 mm: Provides more efficient cooling and more professional cabling ServerMAX Width=780 mm cabinet has all features mentioned before. Plus these additional features. 800x1000 mm Vertical cable management panels can be used at rear of the cabinet for professional cabling and to hide the power cables. Extra Housing space for cabling and power distribution: This extra space provides housing for the vertical cable management panels and the vertical power strips. Left and right front panel: Front panels can be used to hide unwanted views of cables. If server cabinet is additionally used for networking in the front, cable management is needed: Estap cable rings can be used to attach this panel and secure cables.Access holes allow the patch cord to reach the rear of cabinet. 9
  • 11. ServerMAX free standing SELECTION STEPS FOR 600x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure for ServerMAX W=600 mm: Product range name + U height (HHU) The product options have the below structure: Colour option (MX) + Front door option (FX) + Rear door option (RX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example : SRV42U (Width=600 mm) Step 2 Please choose the colour from the table and place it after the part number. For example : SRV42U - M01 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example : SRV42U - M01 - F15 (FX= look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example : SRV42U - M01 - F15 - R07 (RX= look at the RX rear door options on the next page) 10
  • 12. PART NUMBER DEFINITION FOR 600x1000 FX*** MAIN PART NUMBER STRUCTURE SRV Product range ServerMAX F14** U height + SRV Front door options - HHU 600 HHU 26U 36U SRV 42U 47U H SRV : ServerMAX product range (W=600 mm) HHU : “U” height WD : 600x1000 mm Front view F15 R07* 600 OPTIONS MX - FX MX - RX Front door options Colour options + FX M01 F14** M02 600 Rear door options + RX R07* F15 H H R07* MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey Front view Front view RX*** Rear door option FX : Front door options F14**= Single opening, monoblock,welded, curved %63 perforated door, 3 point handled locking F15= Single opening, monoblock,welded, curved plexi glass door, 3 point handled locking R07* 600 RX : Rear door option q R07*= Double opening %63 perforated door with complete metal frame, 3 point handled locking H Back view H= Enclosure height * R07 is the standard rear door. ** F14 is the standard front door. *** F14, F15 R07 can be used as front or rear door. 11
  • 13. ServerMAX free standing TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U R07* / *** F14** / *** F15*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with casters (mm) ServerMAX cabinets 19” 600 x 1000 mm SRV26U 26U 600x1000 mm 26 600 1000 740 1179 1291 1338 SRV36U 36U 600x1000 mm 36 600 1000 740 1623 1735 1782 SRV42U 42U 600x1000 mm 42 600 1000 740 1890 2002 2049 SRV47U 47U 600x1000 mm 47 600 1000 740 2112 2224 2271 * R07 is the standard rear door. ** F14 is the standard front door. *** F14, F15, R07 can be used as front or rear door. 12
  • 14. TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U 565 200 180 (Min 795) 740 H Front view Bottom view Mounting profile 1000 12 600 F14** (Min 25) 56 140 140 906 200 (Min 158) 184 600 600 F15 H Front view 47 H Side view Back view Front view 600 200 R07* 1000 200 600 30 H Top view H= Enclosure height Iso view Front view *R07 is the standard rear door. ** F14 is the standard front door. 13
  • 15. ServerMAX free standing PART NUMBER DEFINITION FOR 800x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure for ServerMAX W=780 mm: Product range name + U height (HHU) + Width (WW, D=1000 mm) The product options have the below structure: Colour option (MX) + Front door option (FX) + Rear door option (RX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example : SRV42U8 (Width=780 mm) Step 2 Please choose the colour from the table and place it after the part number. For example: SRV42U8 - M01 (MX= Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: SRV42U8 - M01 - F16 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: SRV42U8 - M01 - F16 - R08 (RX= Look at the RX rear door options on the next page) 14
  • 16. PART NUMBER DEFINITION FOR 800x1000 FX*** MAIN PART NUMBER STRUCTURE Front door options SRV - HHU - WW Product range ServerMAX SRV Width & depth= 1000 mm U height + HHU + 780 8 42U SRV F16** WW 47U H SRV : ServerMAX product range HHU : “U” height WW : Width (W=780 mm) OPTIONS MX - FX - RX Front door options Colour options MX Front view + FX M01 F16** M02 F17 R08* 780 780 Rear door options + RX F17 R08* H H R08* MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey Front view Front view RX*** Rear door option FX : Front door options F16**= Single opening, monoblock, welded, curved %63 perforated door, 3 point handled locking F17= Single opening, welded, curved plexi glass door, 3 point handled locking R08* 780 RX : Rear door option R08*= Double opening %63 perforated door with complete metal frame, 3 point handled locking H Back view H= Enclosure height * R08 is the standard rear door. ** F16 is the standard front door. *** F16, F17 R08 can be used as front or rear door. 15
  • 17. ServerMAX free standing TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U R08*/*** F16**/*** F17*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with casters (mm) ServerMAX free standing cabinets 19” 780 x 1000 mm SRV42U8 42U 780x1000 mm 42 780 1000 740 1890 2002 2049 SRV47U8 47U 780x1000 mm 47 780 1000 740 2112 2224 2271 * R08 is the standard rear door. ** F16 is the standard front door. *** F16, F17, R08 can be used as front or rear door. 16
  • 18. TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U 780 745 F16** (Min 762) 740 H (Min 27) 44 140 140 906 200 (Min 190) 195 300 280 19” Mounting profile Bottom view 1000 780 12 780 Front view H H Side view 47 Front view F17 Back view Front view 780 780 R08* 200 300 Top view H= Enclosure height 29 1000 H Iso view Front view * R08 is the standard rear door. ** F16 is the standard front door. 17
  • 19. ServerMAX free standing TECHNICAL DRAWINGS FOR 600x1000 Technical drawing of extention unit D=200 mm for 600x1000 mm ServerMAX Top view after extention unit 600 70 200 145 Note: Depth of existing cabinet + 200 mm Exploded view Iso view Part number Width: overall (mm) Depth: overall (mm) Height: without levelling feet (mm) Height: with casters (mm) SRV26U EXT620 26U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 26 600 200 1281 1328 SRV36U EXT620 36U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 36 600 200 1726 1773 SRV42U EXT620 42U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 42 600 200 1993 2040 SRV47U EXT620 18 Product definition (mm) U Size ServerMAX 19” 600 x 1000 mm extention unit 47U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 47 600 200 2215 2262
  • 20. TECHNICAL DRAWINGS FOR 800x1000 Technical drawing of extention unit D=200 mm for 780x1000 mm ServerMAX Top view after extention unit 780 70 200 145 Note: Depth of existing cabinet + 200 mm Exploded view Iso view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Height: without levelling feet (mm) Height: with casters (mm) ServerMAX 19” 780 x 1000 mm extention unit SRV42U EXT820 42U Extention unit D=200 mm, suitable for ServerMAX W=780 mm 42 780 200 1993 2040 SRV47U EXT820 47U Extention unit D=200 mm, suitable for ServerMAX W=780 mm 47 780 200 2215 2262 19
  • 21. ServerMAX free standing TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class 2.3 Storage ETS300019-1-1 Class 1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 20 KEY FEATURES Main profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 90 degrees and consisting of 4 bends for each profile. In total; 16 folds provide framework stability.Additionally, 2 piece vertical side panel divider profile provides additional resistance each with a 4 fold design; total of 8 fold additional support. In total ServerMax main profile framework consists of a 24 fold engineering design. Manufactured and tested to provide axial (x, y, z) resistance that meets EN 61587-1 / 5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Bottom and upper cases have a structure to increase the resistance and strength of the cabinet by monoblock bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper cases with screws. The bottom case providing cable access is fitted with a sliding blanking access plate to prevent dust. A rubber edge on the cable access plate and sliding structure, it is possible to fix the cables and allows cables to be placed into the cabinet without any damage. Additional there are pre-punched knock outs for air distribution delivered from raised floor. Rear door in standard configuration is a double opening door which is removable and lockable. Integral locking is a 3 point locking system. Rear doors can be opened up to 215 degrees, are removable and lockable with handle type locking unit. Side panels have a structure that can be opened and removed with slam latch and key.They are lockable and removable. Side panels consist of a divider profile which creates 2 pieces side panels on each side. Original functional side panel is lockable and removable as mentioned above; the smaller side panel is fixed from inner side with screws. If additional ventilation is needed this panel can be replaced with a slotted / perforated one. Within this engineering construction, the original functional side panel becomes easy to carry while the divider profile provides better resistancy. Front doors are single opening, monoblock, welded, curved, %63 perforated in standard. Integral locking as 3 point locking system. For options please see the related diagrams and technical charts in pages 11-15. Front door can be opened up to 215 degrees, removable and lockable with handle type locking unit. Vented top panel housing with a dedicated space for ventilation, the fan module system allows easy installation of max. 6 fans from top. 19”(inch) mounting angles (2ea. in front and 2ea. in rear) are part of cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels. Levelling feet and integrated castor group are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for enviroment with ISO 14001:2004 Environmental Management System.
  • 22. TECHNICAL SPECIFICATIONS Custom number 85380000 / 85381000 / 853710990019 Packs of (ea.) 1 Shipping structure Assembled Mounting surface Stand alone Load carrying capacity (kg) 1000 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standart colour RAL 7035, RAL 9005 Baying Possible with baying kit for side by side applications without side panels IP protection standard IP20 FRONT DOOR Single opening, monoblock, welded,curved, %63 perforated Front door construction Monoblock curved, welded construction Front door lock Handle type, 3 point locking Hinge system Spring loaded Door opening angle and swapping 215 degree Door opening angle and swapping 215 degree FRAMEWORK Top and bottom base units Solid Metal 2 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 2 mm Uprights construction Tightly fixed into top and bottom base units 3 times folded 3 x 2 = 6 folds SIDE PANEL DIVIDER PROFILE Solid metal 2 mm Side panel construction Tightly fixed into top and bottom base units 4 times folded x 2 = 8 folds INTERIOR PARTS 19’’ mounting angles Solid metal, 2 mm 1 times folded for an L profile system U marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19’’ Zinc plated, passivated, 8-12 micron Adjustable in depth Omega type support rails in depth Solid metal, 1,5 mm 3 times folded for W=600 mm cabinets Omega type folded for W=780 mm cabinets 3 ea. at left, 3 ea. at right 26U and 36U 4 ea. at left, 4 ea. at right 42U and 47U SIDE PANEL Solid metal, 1 mm. Left and right (2ea.) Construction Lockable, removable c/with slam latches and lock Lock Barrel type lock unit, single point + slam latch (2ea) REAR DOOR Solid metal, 1 mm Rear door construction Double door opening, %63 perforated, lockable, removable Rear door lock Handled type lock unit, 3 point Hinge system Spring loaded For CUSTOMIZED PRODUCTS rather than above options, please contact sales department. 21
  • 23. ServerMAX free standing accessories FREQUENTLY USED ACCESSORIES SELECTION CHART FOR SERVERMAX Estap has a wide range of accessories: Heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable managements, cable rings, organisers, trays, plinths and so on... * See the other and part number definition on pages 173-213. * Please state colour choice in your orders. M01=RAL 9005 black and M02= RAL 7035 light grey Frequently used accessories selection table ServerMAX / Vertical PDU part numbers M44 24 AL IEC AMP MCB ServerMAX / Cable management unit (suitable for 780x1000 Server Cabinets) Enclosure sizes* 800x1000 42U M44ORG42SRV 47U M44ORG47SRV ServerMAX / Cable management rings Part number 44x30 K44RING01 44x60 K44RING021U 44x110 K44RING03 70x160 K44RING04 ServerMAX / Floor fixing kit Enclosure sizes* 600x1000 800x1000 M44DPR03 22 * Please check drawing pages for cabinet sizes. M44DPR04
  • 24. Data Center solutions ’Data center solutions which is mission critical, require reliable, flexible and scalable infrastructures alongside guarantied high performance. ESTAP OFFERS energy efficient MANAGABLE, MEASURABLE AND SCALABLE SOLUTIONS TO DATA CENTER PROJECTS. 23
  • 25. Data Center solutions MAIN FEATURES DCMax data center server cabinets are designed to provide hot corridor, cold corridor and its containment structure, which has been widely used in enterprise datacenters. Design criteria serves to provide: • Maximum performance for cooling of IP20 and IP55 solutions • Wide range of cabinet sizes and accessories H=42/47U – W=600/800 mm – D=1000/1100/1200 mm • Load capacity= 1500 kg. DCMax structure is suitable for carrying heavy loads and is seismic tested to 1000 kg (BELLCORE GR-63-CORE ZONE 4, NEBS) • Maximum inner space for servers • Minimum environmental space requirement • Professional cable management • Heavy duty structure • Compability with all vendors servers • High technical performance, grounding continuity • Power / energy management • Controllable and reliable security with monitoring • Aesthetic and professional design 19” OPEN FRAME CABLING CABINET, IP20 Estap System Rack cabinet series offers an ideal solution for the data center which include high density cabling and need effective cooling. Its heavy-duty structure is suitable to house the component of the network backbone. 24 HOT & COLD CORRIDOR APPLICATIONS Estap datacenter cooling solution offers real and energy efficient cooling with its wide product range such as water chilled sidecoolers, in-row coolers, heat removal units, cold corridor containment and so on.
  • 26. Data Center solutions LCD CONSOLES & KVM The high quality KVM switch is ideal for use in small to middle sized server rooms and provides direct connection to many servers. Estap consoles with/without integrated KVM are a space saving and functional solution for a comfortable connection to PCs, servers KVM installations in a 1U rack-mounting area. REMOTE MONITORING SYSTEM Supplies real time monitoring and management solution for data centers to secure flawless operation with high resilien. POWER DISTRIBUTION UNITS (PDU) Estap managed IP PDUs provide reliable power distribution and monitoring of individual outlets to data centers, for both Blade servers. Designed for high density, mission critical server applications, Estap IP PDU range offers an excellent solution to scale electrical power budgets and fight against the inevitable rise of electrical energy costs in the data center business. 25
  • 27. Data Center solutions Data Center solutions ESTAP Data center COOLING SOLUTIONS Estap data center IT cooling solution ensures maximum IT availability at minimum running cost. The power usage effectiveness in the data centers indicates that approximately %30 of the total incoming power is utilised by cooling and cooling related equipment. FEATURES Cold corridor • Liquid / gas cooling • High cooling capacity • Easy mounting and maintenance ESTAP DATA CENTER COOLING SOLUTIONS Hot corridor 26 In Row coolers are utilised. To serve for cooling and/or enhancing the cooling capacity of a cold corridor containment. Heat rejection can be handled by an existing chilled water system: The modular solution serve scalable cooling capacity growth.
  • 28. Universal Line free standing • Provides unique features for system designers, installers and network managers. • Suitable for office, equipment room and cabling closet installations • Exceptionally sturdy and strong • Highly cost-effective and assembly-friendly solutions for numerous applications • Multiple cable entry points provide maximum versatility • Delivered as assembled and side by side mounting is possible 27
  • 29. Universal Line free standing enclosures 600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000 Universal Line free standing enclosures 16U 20U 22U 26U 32U 26U 36U 42U 36U 39U 42U 44U 47U 600 x 600* 600 x 800* 600 x 1000* 47U Universal Line JUMBO free standing enclosures 32U 42U 36U 39U 42U 44U 47U 800 x 1000* 47U Universal Line PCcase 36U 600 x 800* Highly cost-effective and assembly-friendly solutions for numerous applications * Please check drawing pages for cabinet sizes. 28 800 x 600* 800 x 800*
  • 30. UNIVERSAL LINE ENCLOSURES FOR STANDARD DIMENSIONS: Heights:16U, 20U, 22U, 26U 32U, 36U, 39U, 42U, 44U, 47U Width: 600 mm Depth: 600 mm - 780 mm Heights: 26U, 36U, 42U, 47U Width: 600 mm Depth: 1000 mm LOAD CARRYING CAPACITY: 600 kg 600x600 - 600x800 - 600x1000 COLOUR: RAL 9005 black RAL 7035 light grey STANDARDS: ISO 9001: 2008 Quality Management Sytem ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2 KEY FEATURES • The Universal Line free standing cabinets are suitable for office, equipment room, housing server and cabling closet installations. Attention to style with attractive colours black RAL 9005 and light grey RAL 7035 and smoked glass door reinforced with vertical left and right metal frames means that cabinets can be deployed in the most demanding of office environments where appea counts. • However, Universal Line are an exceptionally sturdy and strong cabinet enabling usage for all applications. • Front door frames are available with orange decorative stripe. • The Universal Line offers a highly cost-effective and assembly-friendly solution for numerous applications in the field of network technology and electronics. The Universal Line is highly configurable to the end users requirements and provides unique features to benefit system designers, installers and network managers. • Standard cabinet is completely assembled and delivered as a single enclosure. • Side by side mounting is also possible when side panels are not used; baying kits to be added. • The rigid welded frame construction can be disassembled and assembled easily without any special tools. Thus narrow doors, staircases and elevators are no problem. 29 29
  • 31. Universal Line free standing enclosures Universal Line free standing enclosures offer a wide range of options. 30
  • 32. UNIVERSAL LINE FREE STANDING ENCLOSURES FOR 600x600 - 600x800 - 600x1000 EASY TO ACCESS Front door Features a full-length smoked and shatterproof glass door with decorative accent stripe reinforced with left/right metal frames and integral locking mechanism. Side doors Lockable, removable, complete with slam latches and barrel type locks. 19” mounting angles (front/2ea and back/2ea) allow for flexible configuration and are adjustable in depth. C rails 3 fold 1,5 mm thickness to increase the stability of equipment . Levelling feet included as a standard feature. Rear door Lockable, removable lock. Secure, locking front and back doors with spring loaded hinges offer best accessibility even when connecting the cabinets. The door hinge is easily swapped from one side to the other to change the direction the door opens. Giving you 4-way access to equipment. Front and rear door can be replaced giving you flexibility for different installations. CABLE ACCESS Multiple cable entry points provide maximum versatility. There is a rubber edge sliding cover mechanism that protects and fix the cables. There is a brush on the rear panel that can be positioned on top or bottom (brush entry available on height of 26 U and above) CONSTRUCTION Rigid welded frame construction in steel sheet, rapidly disassembled with 4 screws per corner. Corners of base has welded sockets that tightly fixed into the columns give maximum stability. Frames are made with a 24-fold design for increased stability. Vented Pagoda style top cover with built-in space for available top mount ventilation fan system providing protection against dust flow from the top, additionally this causes a chimney effect to provide passive air flow via convection. 31
  • 33. Universal Line free standing SELECTION STEPS FOR 600x600 - 600x800 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U66 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U66 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U66 - M02 - F01 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U66 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page) 32
  • 34. PART NUMBER DEFINITION FOR 600x600 - 600x800 FX MAIN PART NUMBER STRUCTURE CKR Product range Universal Line F01* Width & Depth U height + CKR Front door options - HHU - WD + HHU F02 600 600 WD 16U 20U 22U 26U 32U H 66 36U CKR H 68 39U 42U 44U Front view 47U Front view F03 CKR : Universal Line free standing product range HHU : “U” height WD : Width and depth F04 600 600 OPTIONS MX - - RX** Front door options Colour options MX FX + FX Rear door options + H H RX M01 F01* R01 M02 F02 R02 F03 * F01 is the standard front door. ** RX - R01 is standard rear door for 22U and below, is optional door for 26U and above R02 is standard rear door for 26U and above with 2 brushed cable access part Front view RX** Rear door options 300 R02 55 MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F01*= Single opening shatter proof glass door with left and right metal frame slotted, single point handled locking F02= Single opening shatter proof glass door with complete metal frame slotted, single point handled locking F03= Single opening solid metal door, single point handled locking F04= Single opening %63 perforated door with complete metal frame slotted, single point handled locking RX** : Rear door options R01= Single opening solid metal rear door with barrel type single point lock unit for 22U and below R02= Single opening solid metal rear door with barrel type single point lock unit with brushed cable entry, for 26U and above Front view R01 600 55 F04 H= Enclosure height 300 Back view Back view 33
  • 35. Universal Line free standing TECHNICAL DRAWINGS FOR 600x600 - 16U/20U/22U R01** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 600 mm CKR16U66 16U 600x600 16 600 600 390 715 865 880 945 CKR20U66 20U 600x600 20 600 600 390 890 1042 1057 1122 CKR22U66 22U 600x600 22 600 600 390 980 1131 1146 1211 * F01 is the standard front door. ** R01 is the standard rear door for 22U and below. 34
  • 36. TECHNICAL DRAWINGS FOR 600x600 - 16U/20U/22U 600 395 F01* (Min 30) 111 300 (Min 520) 390 478 200 H (Min 45) 95 Front view Bottom view 600 19” F02 Mounting profile H 600 600 Front view 600 F03 H Side view Front view H Back view Front view 600 600 600 F04 H Top view H= Enclosure height Iso view Front view * F01is the standard front door. 35
  • 37. Universal Line free standing TECHNICAL DRAWINGS FOR 600x800 - 16U/20U/22U R01** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 780 mm CKR16U68 16U 600x780 16 600 780 555 715 865 880 945 CKR20U68 20U 600x780 20 600 780 555 890 1042 1057 1122 CKR22U68 22U 600x780 22 600 780 555 980 1131 1146 1211 * F01 is the standard front door. ** R01 is the standard rear door for 22U and below. 36
  • 38. TECHNICAL DRAWINGS FOR 600x800 - 16U/20U/22U 600 F01* 395 200 (Min 30) 130 300 658 (Min 701) 555 H (Min 45) 91 Front view 600 F02 19” Bottom view Mounting profile H 600 780 Front view H 600 F03 H H Front view Side view Back view Front view 600 600 780 F04 H Top view H= Enclosure height Iso view Front view * F01is the standard front door. 37
  • 39. Universal Line free standing TECHNICAL DRAWINGS FOR 600x600 - 26U/32U/36U/39U/42U/44U/47U R02** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 600 mm CKR26U66 26U 600x600 26 600 600 390 1160 1309 1324 1389 CKR32U66 32U 600x600 32 600 600 390 1422 1576 1591 1656 CKR36U66 36U 600x600 36 600 600 390 1603 1754 1769 1834 CKR39U66 39U 600x600 39 600 600 390 1735 1887 1902 1967 CKR42U66 42U 600x600 42 600 600 390 1868 2021 2036 2101 CKR44U66 44U 600x600 44 600 600 390 1960 2110 2125 2190 CKR47U66 47U 600x600 47 600 600 390 2093 2244 2259 2324 * F01 is the standard front door. ** R02 is the standard rear door for 26U and above. 38
  • 40. TECHNICAL DRAWINGS FOR 600x600 - 26U/32U/36U/39U/42U/44U/47U 600 F01* 395 H (Min 520) 390 (Min 45) 95 478 200 (Min 30) 111 300 Bottom view Front view F02 600 19” Mounting profile 600 300 55 600 H Front view 600 F03 55 H Front view H 300 Back view Side view 600 Front view F04 600 600 H Top view H= Enclosure height Iso view Front view * F01 is the standard front door. 39
  • 41. Universal Line free standing TECHNICAL DRAWINGS FOR 600x800 - 26U/32U/36U/39U/42U/44U/47U R02** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 780 mm CKR26U68 26U 600x780 26 600 780 555 1160 1309 1324 1389 CKR32U68 32U 600x780 32 600 780 555 1422 1576 1591 1656 CKR36U68 36U 600x780 36 600 780 555 1603 1754 1769 1834 CKR39U68 39U 600x780 39 600 780 555 1735 1887 1902 1967 CKR42U68 42U 600x780 42 600 780 555 1868 2021 2036 2101 CKR44U68 44U 600x780 44 600 780 555 1960 2110 2125 2190 CKR47U68 47U 600x780 47 600 780 555 2093 2244 2259 2324 * F01 is the standard front door. ** R02 is the standard rear door for 26U and above. 40
  • 42. TECHNICAL DRAWINGS FOR 600x800 - 26U/32U/36U/39U/42U/44U/47U 395 600 F01* 200 (Min 30) 130 300 (Min 45) 91 658 (Min 701) 555 H Bottom view Front view F02 600 19” Mounting profile 780 300 55 600 H Front view 600 F03 55 H H 300 Front view Side view Back view 600 Front view F04 780 600 H Top view H= Enclosure height Iso view Front view * F01is the standard front door. 41
  • 43. Universal Line free standing SELECTION STEPS FOR 600x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U6100 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U6100 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U6100 - M02 - F01 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U6100 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page) 42
  • 44. PART NUMBER DEFINITION FOR 600x1000 FX MAIN PART NUMBER STRUCTURE CKR Product range Universal Line CKR Front door options - HHU - WD + HHU F05* Width & Depth U height + F06 600 600 WD 26U 6100 36U CKR 42U 47U H CKR : Universal Line free standing product range HHU : U height WD : Width and depth H Front view Front view F07 OPTIONS F08 600 600 MX - FX - RX Front door options Colour options MX + FX Rear door options + RX F05* R01 M02 F06 R02* F07 R03 F08 F04 MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F05*= Single opening tempered proof glass door with left and right metal frame slotted, single point handled locking F06= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F07= Single opening solid metal door, single point handled locking F08= Single opening %63 perforated door with complete metal frame slotted, single point handled locking RX : Rear door options R01= Single opening solid metal rear door with barrel type, single point lock unit R02*= Single opening solid metal rear door with barrel type, single point lock unit, brushed cable entry on top and bottom R03= Double opening % 63 perforated rear door with complete frame, 3 point handled locking F04= Single opening %63 perforated door with complete metal frame slotted, single point handled locking H H Front view Front view RX Rear door options R02* 300 R03 R01 F04 55 M01 Back view Back view Back view Back view H= Enclosure height * F05 and R02 are the standard doors 43
  • 45. Universal Line free standing TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U R01 R03 F04 R02** F05* F06 F07 F08 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 1000 mm CKR26U6100 26U 600x1000 26 600 1000 740 1175 1309 1324 1389 CKR36U6100 36U 600x1000 36 600 1000 740 1620 1754 1769 1834 CKR42U6100 42U 600x1000 42 600 1000 740 1889 2021 2036 2101 CKR47U6100 47U 600x1000 47 600 1000 740 2110 2244 2259 2324 * F05 is the standard front door. ** R02 is the standard rear door for 26U and above. 44
  • 46. TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U 600 395 F05* 200 (Min 30) 150 300 878 (Min 921) 740 H Front view (Min 45) 106 Bottom view 1000 19” Mounting profile 300 55 600 F06 600 H Front view 600 F07 55 H Front view H 300 Back view Side view 600 Front view F08 1000 600 H Top view H= Enclosure height Iso view Front view * F05 is the standard front door. 45
  • 47. Universal Line free standing TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 46 KEY FEATURES Main profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 45 degrees and consisting of 6 bends for each profile. In total; 24 folds provide framework stability. Tested to provide (x, y, z) axis resistance that meets EN 61587-1/5.2.1 and 5.2.2 and external impact resistance that meets EN 615871/5.3.3. Bottom and upper case have a structure which increases resistance and strength of cabinet by mono-block bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper case with screws. Cable access at bottom case has a sliding type blanking access plate that would block dust inlet. A rubber edge on the cable access plate with sliding structure, allows fixing of cables into the cabinet without any damage. Rear door is manufactured with 2 cable access parts 1 ea. with brush on top 1 ea. on bottom for 26 U and above sizes*. Rear door in standard configuration is a single opening door which is removable and lockable. For options please see the related diagrams and technical charts on pages 33-43. Side panels have a structure that can be opened and removed with slam latch and key and are lockable and removable. Front doors are a framed glass structure which is tempered, anti-static, secure and smoked glass (4 mm thickness) with a decorative stripe, according to EN 12150-1:2000 standard. Front door in standard configuration has left and right metal frame structure with high density polyurethane adhesive and screw. For front door options please see the related diagrams and technical charts on pages 33-43. Front door can be opened to 125 degrees, removable and lockable with handle type locking unit. Pagoda style vented top panel with a dedicated space of ventilation fan module system allows easy installation of max. 4 fans. 19”(inch) mounting angles (2ea. in front and 2ea. in rear) are part of the cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels. Levelling feet are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for environment with ISO 14001:2004 Environmental Management System. * Please see related diagrams to define the difference of rear door design between up to 26U and above 26U
  • 48. TECHNICAL SPECIFICATIONS Custom number 85380000 / 85381000 / 853710990019 Shipping structure Assembled Mounting type Stand alone Load carrying capacity (kg) 600 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standard colour RAL 7035, RAL 9005 Standard stripe colour Orange IP protection standard IP20 FRONT DOOR Shatterproof glass with left and right metal frame Glass 4 mm thickness full-length smoked, shatterproof, tempered, secure Front door construction Single door opening Front door lock Handle type, single point locking Adhesive material High density polyurethane DIN 53479, DIN 53505 Hinge system Spring loaded Door opening angle and swapping 125 degree, possible to swap one side to the other SIDE PANEL Solid metal, 1 mm left and right (2ea.) Side panel construction Lockable, removable c/with slam latches and lock Side panel lock Barrel type lock unit, single point + Slam latch (2ea) REAR DOOR Solid metal, 1 mm Rear door construction Single opening, solid metal with brushed cable entry on top and bottom. Rear door lock Barrel type lock unit, single point Hinge system Spring loaded Door opening angle and swapping 125 degree, possible to swap one side to the other TOP COVER Solid metal 1 mm Top cover construction Pagoda type structure provides efficient air removal FRAMEWORK Top and bottom base units Solid metal 1,5 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 1,5 mm Uprights construction Tightly fixed into top and bottom base units 6 times folded INTERIOR PARTS 19’’ mounting angles Solid metal, 1,5 mm 3 times folded 600x600, 600x780 / 1 time folded for 600x1000 “U” marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19’’ Zinc plated, passivated, 8-12 micron. Adjustable in depth C type support rails in depth Solid metal, 1,5 mm 3 times folded, 2 ea. at left , 2 ea. at right up to 26U 3 ea. at left , 3 ea. at right 26U and higher OPTIONS For front and rear door options, please look at pages 33-43. For CUSTOMIZED PRODUCTS rather than above options, please contact sales department. 47
  • 49. Universal Line JUMBO free standing SELECTION STEPS FOR 800x800 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U88 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U88 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U88 - M02 - F09 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U88 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page) 48
  • 50. PART NUMBER DEFINITION FOR 800x600 - 800x800 FX MAIN PART NUMBER STRUCTURE CKR - HHU - WD Product range Universal Line CKR Width & Depth U height + HHU + F09* WD 32U F10 780 780 86 36U CKR Front door options 88 39U H H 42U 44U 47U CKR : Universal Line free standing product range HHU : “U” height WD : Width and depth Front view F11 Front view F12*** 780 R04** 780 780 OPTIONS MX - FX - RX Front door options Colour options MX + FX Rear door options + H H H RX M01 F09* R04** M02 F10 R05 F11 R06* F12*** F12*** Front view * F09 and R06 are the standard doors. ** R04 can be usable as front door also. *** F12 used as rear door as well. Front view RX R04** Rear door options R04** R06* 55 300 H 55 MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F09*= Double opening tempered proof glass door with left and right metal frame slotted, two point barrel type locking F10= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F11= Single opening solid metal door, single point handled locking F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking R04**= Double opening %63 perfore door with complete metal frame, 3 point handled locking RX : Rear door options R06*= Double opening complete metal door with brushed cable entry, barrel type single point lock unit. R04**= Double opening %63 perforated door with complete metal frame, 3 point handled locking R05= Single opening solid metal rear door with barrel type, single point lock unit F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking Front view 300 Back view R05 Back view Back view F12*** Back view H= Enclosure height 49
  • 51. Universal Line JUMBO TECHNICAL DRAWINGS FOR 800x600 - 32U/36U/39U/42U/44U/47U F12*** R05 R04** R06* F09* F10 F11 R04** F12*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line JUMBO cabinets 19” 780 x 600 mm CKR32U86 32U 780x600 32 780 600 365 1422 1576 1591 1656 CKR36U86 36U 780x600 36 780 600 365 1603 1754 1769 1834 CKR39U86 39U 780x600 39 780 600 365 1735 1887 1902 1967 CKR42U86 42U 780x600 42 780 600 365 1868 2021 2036 2101 CKR44U86 44U 780x600 44 780 600 365 1960 2110 2125 2190 CKR47U86 47U 780x600 47 780 600 365 2093 2244 2259 2324 * F09 and R06 are the standard doors. ** R04 is usable as front door also. *** F12 is usable as rear door also. 50
  • 52. TECHNICAL DRAWINGS FOR 800x600 - 32U/36U/39U/42U/44U/47U F09* 515 F10 780 300 478 (Min 408) 365 55 H (Min 138) 141 200 780 (Min 50) 90 300 19” Bottom view Front view Mounting profile 780 Front view F11 780 300 55 600 H H H H Front view F12 55 780 Front view 300 Side view H Back view Front view 780 R04 55 300 600 780 H Top view H= Enclosure height Iso view Front view * F09 is the standard door. 51
  • 53. Universal Line JUMBO TECHNICAL DRAWINGS 800x800 - 32U/36U/39U/42U/44U/47U F12*** R05 R04** R06* F09* F10 F11 R04** F12*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line JUMBO cabinets 19” 780 x 780 mm CKR32U88 32U 780x780 32 780 780 550 1422 1576 1591 1656 CKR36U88 36U 780x780 36 780 780 550 1603 1754 1769 1834 CKR39U88 39U 780x780 39 780 780 550 1735 1887 1902 1967 CKR42U88 42U 780x780 42 780 780 550 1868 2021 2036 2101 CKR44U88 44U 780x780 44 780 780 550 1960 2110 2125 2190 CKR47U88 47U 780x780 47 780 780 550 2093 2244 2259 2324 * F09 and R06 are the standard doors. ** R04 is usable as front door also *** F12 is usable as rear door also. 52
  • 54. TECHNICAL DRAWINGS FOR 800x800 - 42U/47U 515 300 (Min 40) 95 F10 780 (Min 720) 550 780 H H (Min 130) 131 658 300 85 300 F09* Front view 19” Bottom view Mounting profile Front view F11 780 780 300 55 780 H H H Front view F12 55 780 Front view 300 Side view Back view H 780 Front view R04 55 780 300 780 H Top view H= Enclosure height Iso view Front view * F09 is the standard front door. 53
  • 55. Universal Line JUMBO free standing SELECTION STEPS FOR 800x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U8100 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U8100 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U8100 - M02 - F09 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U8100 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page) 54
  • 56. PART NUMBER DEFINITION FOR 800x1000 FX MAIN PART NUMBER STRUCTURE CKR - HHU - WD Product range Universal Line CKR Front door options Width & Depth U height + HHU + WD H H Front view 780 47U CKR : Universal Line product range HHU : “U” height WD : Width and depth OPTIONS F10 780 8100 42U CKR F09* F11 Front view F12*** 780 R04** 780 780 MX - FX - RX Front door options Colour options MX + FX Rear door options + H RX M01 F09* R04** M02 F10 R05 F11 R06* F12 H F12*** Front view Front view Front view R04** RX MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F09*= Double opening tempered proof glass door with left and right metal frame slotted, two point barrel type locking F10= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F11= Single opening solid metal door, single point handled locking F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking R04**= Double opening %63 perforated door with complete metal frame, 3 point handled locking RX : Rear door options R05= Single opening solid metal rear door with barrel type, single point lock unit R04**= Double opening %63 perforated door with complete metal frame, 3 point handled locking R06*= Double opening complete metal door with brushed cable entry, barrel type single point lock unit. F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking Rear door options * F09 and R06 are the standard doors ** R04 is usable as front door also. *** F12 is usable as rear door also. R04** R06* 55 300 55 H 300 Back view R05 Back view Back view F12*** Back view H= Enclosure height 55
  • 57. Universal Line JUMBO TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U F12*** R05 R04** R06* F09* F10 F11 R04** F12*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line JUMBO cabinets 19” 780 x 1000 mm CKR42U8100 42U 780X1000 42 780 1000 740 1889 2021 2036 2101 CKR47U8100 47U 780X1000 47 780 1000 740 2110 2244 2259 2324 * F09 and R06 are the standard doors. ** R04 is usable as front door also. *** F12 is usable as rear door also. 56
  • 58. TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U 515 300 (Min 26) 120 F10 780 780 (Min 852) 740 (Min 118) 136 878 300 85 300 F09* Bottom view H H Front view 19” Mounting profile Front view F11 780 780 1000 55 300 H H H Front view 55 F12 780 300 Front view Side view Back view H 780 Front view R04 780 1000 300 55 H Top view H= Enclosure height Iso view Front view * F09 is the standard front door. 57
  • 59. Universal Line JUMBO TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 58 KEY FEATURES Main profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 45 degrees and consisting of 6 bends for each profile. In total; 24 folds provide framework stability.Tested to provide (x, y, z) axis resistance that meets EN 61587-1 / 5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Bottom and upper case have a structure to increase resistance and strength of cabinet by mono block bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper case with screws.The bottom case providing cable access is fitted with a sliding blanking access plate to prevent dust. A rubber edge on the cable access plate and sliding structure, allows cables to be placed into the cabinet and fixed inside with no damage. Additionally both on top and bottom, there are brushed cable entry plates for mass cabling needs. Rear door is manufactured with 2 cable access part top/ bottom with brush. Rear door in standard configuration is a double opening door which is removable and lockable. For options please see the related diagrams and technical charts in pages 4955. Side panels have a structure that can be opened and removed with slam latch and key and are lockable and removable. Front doors are a framed glass structure which is tempered, anti-static, secure and smoked glass (4 mm thickness) with a decorative stripe, according to EN 12150-1:2000 standard. Front door in standard configuration has left and right metal frame structure with high density polyurethane adhesive and screw and double opening. For options please see the related diagrams and technical charts in pages 49-55. Front door is a double openning door which can be opened to 125 degrees, removable and lockable with handle type locking unit. Pagoda style vented top panel with a dedicated space of ventilation fan module system allows easy installation of max. 4 fans. 19”(inch) mounting angles (2 ea. in front and 2 ea. in rear) are part of the cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels.. Levelling feet are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for enviroment with ISO 14001: 2004 Environmental Management System.
  • 60. TECHNICAL SPECIFICATIONS Custom number 85380000 / 85381000 / 853710990019 Shipping structure Assembled Mounting type Stand alone Load carrying capacity (kg) 600 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standard colour RAL 7035, RAL 9005 Standard stripe colour Orange Baying Possible with baying kit for side by side applications without side panels IP protection standard IP20 FRONT DOOR Shatterproof glass with left and right metal frame Glass 4 mm thickness full-length smoked, shatterproof, tempered, secure Front door construction Double opening door Front door lock 2 point locking barrel type Adhesive material High density polyurethane DIN 53479, DIN 53505 Hinge system Spring loaded Door opening angle and swapping 125 degree SIDE PANEL Solid metal, 1 mm left and right (2 ea.) Side panel construction Lockable, removable c/with slam latches and lock Side panel lock Barrel type lock unit, single point + Slam latch (2 ea) REAR DOOR Solid metal, 1 mm Rear door construction Double door opening, lockable, removable Rear door lock Barrel type lock unit, single point Hinge system Spring loaded Door opening angle and swapping 125 degree TOP COVER Solid metal 1,2 mm Top cover construction Pagoda type, allows efficient air removal FRAMEWORK Top and bottom base units Solid metal 1,5 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 1,5 mm Uprights construction Tightly fixed into top and bottom base units 6 times folded INTERIOR PARTS 19’’ mounting angles Solid metal, 1,5 mm 3 times folded 800x600, 800x800 / 1 time folded for 800x1000 “U” marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19’’ Zinc plated, passivated, 8-12 micron. Adjustable in depth Omega type support rails in depth Solid metal, 1,5 mm 3 times folded 2 ea. at left , 2 ea. at right up to 26U 3 ea. at left , 3 ea. at right 26U and higher OPTIONS For the front and rear door options, please look at pages 49-55. For CUSTOMIZED PRODUCTS rather than above options, please contact sales department. 59
  • 61. Universal Line JUMBO Accessories SPECIAL ACCESSORIES* FOR JUMBO Teleskopic cable trunking Designed to protect and hide cable bundles coming from the ceiling. Since the height between ceiling and cabinet is variable, it is manufactured as telescopic to fit all dimensions. Coming complete with cover which when closed gives a professional look. Vertical cable management channels (left and right) Designed to manage large patch cable bundles in front of the cabinet. It is installed through the height of the cabinet, and each “U” dimension, there is a hole to pass horizontal patch cables on vertical axis. A spring hinged cover in front of the vertical cable management panel integral with slam latch.The cover protect and hide all cable bundles. When it is closed, it gives a professional look. Labour costs are reduced by %20 and is a time saving system. Vertical cable management trunking Designed to carry large cable bundles through the vertical axis of the cabinet. From top to bottom, it is continuous with the height of cabinet. Bottom edge of the trunking fits into the cabinet bottom cable entry, top edge of the trunking fits into the cabinet top cable entry. It has holes for cable access for horizantal axis. It is punched in a shape to tie the cables. Since it has a sliding cover on the trunking, cable bundles are hidden and protected. When closed, it offers a chic looking finish. *See accessories for product part numbers, definitions and please contact sales department. Professional cabling solutions with JUMBO Left and right cable management panels hide and protect all networking cables as well as providing a professional looking finish. Double opening rear doors provide space saving between cabinet and wall. 60
  • 62. UNIVERSAL LINE JUMBO FEATURES Perforated, vented Pagoda-style top providing maximum protection against dust Front door with integrated locking mechanism for added security. Side panel comes with snap closures and locks providing security, whilst allowing four-way access to the equipment. Sliding access panel on the bottom for cable entry and a brush entry on the rear panel that can be positioned on the top or bottom 61
  • 63. Universal Line PCcase free standing 600x800 - 36U STANDARD DIMENSIONS: Height: 36U Width: 600 mm Depth: 780 mm STANDARDS: ISO 9001: 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipments) Overall cabinet dimensions to IEC 297-2 COLOUR: RAL 9005 black RAL 7035 light grey • 19” • FITS YOUR DECOR AND ENVIRONMENT • SECURE AND STURDY • EASY TO MAINTAIN AND LARGE INNER VOLUME • DUST PROOF • AIR CIRCULATION WITH VENTED FILTERS 62 PCcase is ideal for office, factory, workshop, storage, store, gas stations and laboratories etc. as server housing. It protects your servers and devices against dust, humidity, hot/cold air but most important that against unauthorized peoples. Servers, all kind of PC’s, monitors, keyboards, UPS’s, switches and networking products can easily be placed in it. Its agronomy provides the keyboards at hands level and monitor is at eye level.
  • 64. 600x800 - 36U FEATURES PCccase cabinets match all features defined for Universal Line as main construction. It has 3 sections; 1st compartment: Screen section 11U space covered, (not 19’’, equipped with a fixed shelf which should be base for the screen unit). 2nd Compartment: Keyboard section 3U space covered (not 19’’, equipped with a specific sliding shelf integrated with mouse housing and platform). 3rd Compartment: Device section 19” 22U usable (19’’, 22U rail allowing use of all standard accessories to mount all kind of devices printers, UPS, server or any LAN/WAN devices...) All compartments are lockable. Both side doors are lockable, removable, and openable. Side doors have filtered and vented air circulation trays that allow air circulation or air entry. It is possible to use together with cooling fans which also has filtered and vented tray on top that allow air circulation. Bottom section has two door options: Glass door or solid metal door. 63
  • 65. Universal Line PCcase TECHNICAL DRAWINGS 600x800 - 36U Exploded view Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) 36U 600x780 mm PCcase, metal door section at bottom Height: vertical mounting profile (mm) PCCASE36M Depth: max mounting profile (mm) 36U 600x780 mm PCcase, glass door section at bottom Depth: overall (mm) PCCASE36 64 Product definition (mm) Width: overall (mm) Part number U Size Universal Line PCcase cabinets 19” 600 x 780 mm 36 600 780 555 1603 1766 1781 1846
  • 66. TECHNICAL DRAWINGS FOR 600x800 - 36U 395 600 (Min 30) 91 1746 (Min 701) 555 658 200 (Min 30) 130 300 19” Bottom view Mounting profile 600 780 1746 Front view with glass door 600 Front view Side view Back view 1746 600 780 302 350 Front view with metal door Top view Iso view 65
  • 67. Universal Line free standing accessories FREQUENTLY USED ACCESSORIES SELECTION TABLE FOR Universal Line Estap has a wide range of accessories: Fixed shelves, heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable managements, cable rings, organisers, trays, plinth and so on... * See the other accessories and part number definitions on pages 173-213. * Please state colour choice in your orders. M01=RAL 9005 black and M02= RAL 7035 light grey Frequently used accessories selection table Universal Line / Shelves part numbers Fixed shelves Enclosure Sizes* PCcase 600x800 600x1000 800x600 800x800 800x1000 M44SBR80 M44SBR60 M44SBR80 M44SBR100 M44SBR60 M44SBR80 M44SBR100 Heavy duty fixed shelves Sliding shelves 600x600 - - - M55SR720 M44HRK80 M44HRK60 M44HRK80 Heavy duty sliding shelves - - - - - - M44HRK60 M44HRK80 M55HR720 M55SR720 - - - M55HR720 Universal Line / Fan units part numbers PCcase 600x600 600x800 600x1000 800x600 800x800 800x1000 2 Fan unit with on/off switch M44HV2F M44HV2F M44HV2F M44HV2F M44HV2F M44HV2F M44HV2F 4 Fan unit with on/off switch M44HV4F M44HV4F M44HV4F M44HV4F M44HV4F M44HV4F M44HV4F 2 Fan unit with thermostat unit M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT 4 Fan unit with thermostat unit M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT Universal Line / Cable management part numbers 1U cable management panel (5 rings) Vertical cable management Universal Line / PDU part numbers Enclosure Sizes* Enclosure Sizes* PCcase 600x600 600x800 600x1000 800x600 E44ORG1U E44ORG1U E44ORG1U E44ORG1U E44ORG1U - - - - 800x800 800x1000 E44ORG1U E44ORG1U M44ORGxxU M44ORGxxU M44ORGxxU Enclosure Sizes* PCcase 600x600 600x800 600x1000 800x600 800x800 800x1000 6 way PDU with 1x16A CCT breaker,1U M446AL M446AL M446AL M446AL M446AL M446AL M446AL 9 way PDU with 1x16A CCTbreaker, 2U M449ALC M449ALC M449ALC M449ALC M449ALC M449ALC M449ALC 800x600 800x800 800x1000 Universal Line / Castor part numbers Castor group Fixings/ cagenut, screw, washer (1set=20 pcs.) 66 Enclosure Sizes* PCcase 600x600 600x800 600x1000 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 KFS6X15 * Please check drawing pages for cabinet sizes. KFS6X15 KFS6X15 KFS6X15 KFS6X15 KFS6X15 M22TKGR1 KFS6X15
  • 68. EUROline free standing Reduce %ip5e0t sh m n * cost • Real flatpack design • Max. 10 min** for assembly • Easy to carry and transport • Easy to maintenance • High volume capacity for large cable bundles * Mixed quantity and mixed size ** Measured values by Estap. It can change according to size of the enclosure 67
  • 69. EUROline free standing 600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000 EUROline free standing enclosures 22U 26U 32U 36U 42U 600 x 600* 42U 600 x 1000* 32U 36U 42U 800 x 800* 42U 800 x 1000* 600 x 800* Openable, lockable, removable side panels, front and rear doors • 19” • MODULAR STRUCTURE • READY FOR ASSEMBLY • STURDY, RUGGED STEEL CONSTRUCTION • REDUCE THE SHIPMENT COST • FLATPACK * Please check drawing pages for cabinet sizes. 68
  • 70. 600x600 - 600x800 - 600x1000 - 800x800 - 800x1000 STANDARD DIMENSIONS: Heights: 22U, 26U, 32U, 36U, 42U Width: 600 mm Depth: 645 mm and 825 mm LOAD CARRYING CAPACITY: 400 kg Heights: 42U Width: 600 mm Depth: 1005 mm RAL 7035 light grey Heights: 32U, 36U, 42U Width: 780 mm Depth: 825 mm Height: 42U Width: 780 mm Depth: 1005 mm COLOUR: RAL 9005 black STANDARDS: ISO 9001: 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2 KEY FEATURES • High quality production • Aesthetic look • Sturdy, rugged steel construction • Openable, lockable, removable side panels, front and rear doors. • Secure, tempered front door, with left&right metal frames, and handle type lock. • Easy to maintain, high volume capacity for large cable bundles. • Upper case is suitable for fan units and brushed cable entry. • Welded corners and sturdy construction. • Bottom case is completely open for large cable entries. Bottom plate with sliding type Estap standard cable entry, can be used to close case. • Rugged steel for 19” mounting angles • Reduce shipment costs %50* • Easy to transport • Strong protection against transport damages • Easy to assemble • After mounting, cardboard packaging and wooden pallets may be retained and reused for future shipments. * Mixed quantity and mixed size 69
  • 71. EUROline free standing SELECTION STEPS FOR 600x600 - 600x800 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and ‘’Options’’ sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: EU42U68 Step 2 Please choose the colour from the table and place it after the part number. For example: EU42U68 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: EU42U68 - M02 - F18 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: EU42U68 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page) 70
  • 72. PART NUMBER DEFINITION 600x600 - 600x800 FX MAIN PART NUMBER STRUCTURE EU Front door option - HU - WD H Product range EUROline EU Width & depth U height + HHU 22U + F18 WD 66 68 26U EU 600 32U 36U 42U EU : EUROline free standing product range HHU : “U” height WD : Width and depth H OPTIONS MX - FX - RX Front door option Colour MX M01 + FX F18 Rear door option + RX Front view R10 RX M02 Rear door option 600 R10 MX : Colour options RAL 9005 black M01= RAL 7035 light grey M02= FX : Front door option Single opening shatter proof glass door with left F18= and right metal frame slotted, single point handled locking H RX : Rear door option Single opening solid metal rear door with R10= barrel type lock unit, single point H= Enclosure height Back view 71
  • 73. EUROline free standing TECHNICAL DRAWINGS FOR 600x600 - 22U/26U/32U/36U/42U R10 F18 * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 600 x 645 mm EU22U66 22U 600x645 22 600 645 331,5 1070 1135 1150 1215 EU26U66 26U 600x645 26 600 645 331,5 1245 1310 1325 1370 EU32U66 32U 600x645 32 600 645 331,5 1515 1575 1590 1655 EU36U66 36U 600x645 36 600 645 331,5 1700 1755 1770 1825 EU42U66 42U 600x645 42 600 645 331,5 1960 2025 2040 2105 * Bottom cover plate is an optional accessory. 72
  • 74. TECHNICAL DRAWINGS FOR 600x600 - 22U/26U/32U/36U/42U F18 600 H (Min 93,5) 155 566 (Min 455) 331,5 (Min 91,5) 153 521 19” Bottom view* Note: *Bottom is empty, the top of the Front view Mounting profile enclosure appears 600 645 566 521 300 200 H Bottom view* Note: * Bottom cover plate is an optional accessory Side view 645 600 300 Back view 72 Front view Top view H= Enclosure height Iso view 73
  • 75. EUROline free standing TECHNICAL DRAWINGS FOR 600x800 - 22U/26U/32U/36U/42U R10 F18 * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 600 x 825 mm EU22U68 22U 600x825 22 600 825 511,5 1070 1135 1150 1215 EU26U68 26U 600x825 26 600 825 511,5 1245 1310 1325 1395 EU32U68 32U 600x825 32 600 825 511,5 1515 1575 1590 1655 EU36U68 36U 600x825 36 600 825 511,5 1700 1755 1770 1840 EU42U68 42U 600x825 42 600 825 511,5 1960 2025 2040 2110 * The bottom cover plate is an optional accessory. 74
  • 76. TECHNICAL DRAWINGS FOR 600x800 - 22U/26U/32U/36U/42U 521 F18 (Min 635) 511,5 746 (Min 91,5) 153 600 (Min 91,5) 153 H 19” Bottom view* Mounting profile Note: * Bottom is empty, the top of the enclosure appears 521 825 746 200 600 Front view 300 H Bottom view* Note: * Bottom cover plate is an optional accessory Side view Front view Back view 825 72 600 300 Top view H= Enclosure height Iso view 75
  • 77. EUROline free standing SELECTION STEPS FOR 600x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and ‘’Options’’ sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 - Please choose product part number. For example: EU42U61 Step 2 - Please choose the colour from the table and place it after the part number. For example: EU42U61 - M02 (MX=Look at the MX colour options on the next page) Step 3 - Please choose the front door from the table and place it after MX colour. For example: EU42U61 - M02 - F18 (FX= Look at the FX front door options on the next page) Step 4 - Please choose the rear door from the table and place it after FX front door option. For example: EU42U61 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page) 76
  • 78. PART NUMBER DEFINITION FOR 600x1000 FX MAIN PART NUMBER STRUCTURE Front door options EU - HHU - WD Product range EUROline EU Width & depth U height + EU HHU + WD 600 61 42U EU : EUROline free standing product range HHU : “U” height WD : Width and depth F21 600 F18* H H OPTIONS MX - FX - RX Front door options Colour options MX + FX Front view Front view Rear door options + RX M01 F18* R10** M02 F21 R07 RX RX Rear door options Rear door options MX : Colour options RAL 9005 black M01= RAL 7035 light grey M02= FX : Front door options Single opening shatter proof glass door with F18*= left and right metal frame slotted, single point handled locking Single opening %63 perforated front door, F21= full slotted frame, single point handled locking RX : Rear door options Single opening solid metal rear door with R10**= barrel type lock unit, single point locking Double opening complete framed % 63 R07= perforated front door, 3 point handled locking 600 R10** 600 H Back view R07 H Back view H= Enclosure height H= Enclosure height * F18 is the standard front door. ** R10 is the standard rear door. 77
  • 79. EUROline free standing TECHNICAL DRAWINGS FOR 600x1000 - 42U R07 R10** F21 F18* Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 600 x 1005 mm EU42U61 42U 600x1005 42 600 1005 702,5 1960 2025 2040 2110 * F18 is the standard front door. ** R10 is the standard rear door. 78
  • 80. TECHNICAL DRAWINGS FOR 600x1000 - 42U 600 522 (Min 85,5) 147 522 (Min 825,5) 702,50 926 463 (Min 86,5) 148 F18* Bottom view* Note: *Bottom is empty, the top of the enclosure appears H 19” Mounting profile 600 Front view 1005 600 H F21 H Side view Front view Back view Front view 600 1005 72 300 Top view Iso view H= Enclosure height * F18 is the standard front door. 79
  • 81. EUROline free standing SELECTION STEPS FOR 800x800 - 800x1000 STEPS TO SELECT RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section on the catalogue, has a ‘’Main part numbers’’ and ‘’Options’’ sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: EU42U88 or EU42U81 Step 2 Please choose the colour from the table and place it after the part number. For example: EU42U88 - M02 (MX=Look at the MX colour options on the next page) or EU42U81 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: EU42U88 - M02 - F20 (FX= Look at the FX front door options on the next page) or EU42U81 - M02 - F20 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: EU42U88 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page) or EU42U81 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page) 80
  • 82. PART NUMBER DEFINITION 800x800 - 800x1000 FX MAIN PART NUMBER STRUCTURE EU - HHU - WD Product range EUROline EU Width & depth U height + HHU 32U Front door options + 780 H H 81 EU : EUROline free standing product range HHU : “U” height WD : Width and depth Front view Front view RX OPTIONS MX - FX - Rear door options RX 780 Front door options Colour options MX + FX F19* 88 42U 42U 780 WD 36U EU F20** R12*** Rear door options + RX M01 F20** R12*** M02 F19* R11 R08* R08* H F19* MX : Colour options RAL 9005 black M01= RAL 7035 light grey M02= Back view 780 FX : Front door options Double opening shatter proof glass door with F20**= left and right metal frame slotted, 3 point handled locking Single opening %63 perforated front door, F19= full slotted frame, single point handled locking Double opening complete framed %63 R08*= perforated front door, 3 point handled locking RX : Rear door options Double opening metal rear door with R12***= 3 point handled locking Single opening solid metal rear door with R11= barrel type lock unit, single point lock unit Double opening complete framed %63 R08*= perforated front door, 3 point handled locking F19*= Single opening %63 perforated front door, full slotted frame, single point handled locking H Back view R08* 780 H H= Enclosure height * R08 and F19 can be used as both front and rear door. ** F20 is the standard front door. *** R12 is the standard rear door. R11 Back view 81
  • 83. EUROline free standing TECHNICAL DRAWINGS FOR 800x800 - 32U/36U/42U F19** R08** R11 R12**** F19** F20*** R08** * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 780 x 825 mm EU32U88 32U 780x825 32 780 825 511,5 1515 1525 1540 1655 EU36U88 36U 780x825 36 780 825 511,5 1630 1755 1770 1840 EU42U88 42U 780x825 42 780 825 511,5 1960 2025 2040 2110 * The bottom cover plate is optional. ** R08 and F19 can be used as both front and door rear door. *** F20 is the standard front door. **** R12 is the standard rear door. 82
  • 84. TECHNICAL DRAWINGS FOR 800x800 - 32U/36U/42U 780 F20* 701 (Min 725) 511,5 H (Min 47,5) 154 776 746 (Min 44,5) 151 513 19” Bottom view* Mounting profile Note: *Bottom is empty, the top of the Front view enclosure appears 780 701 825 780 F19 200 300 746 H H Bottom view Note: Bottom cover plate is an optional accessory Front view Side view Back view Front view 780 Top view H= Enclosure height 747 300 300 R08 72 702 H Iso view Front view * F20 is the standard front door. 83
  • 85. EUROline free standing TECHNICAL DRAWINGS FOR 800x1000 - 42U F19** R08** R12**** R11 F19** F20*** R08** * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 780 x 1005 mm EU42U81 42U 780x1005 42 780 1005 704,5 1960 2025 2040 2110 * The bottom cover plate is optional. ** R08 and F19 can be used as both front and door rear door. *** F20 is the standard front door. **** R12 is the standard rear door. 84
  • 86. TECHNICAL DRAWINGS FOR 800x1000 - 42U 701 513 780 H (Min 40) 146,5 926 (Min 784,5) 704,50 (Min 40) 146,5 F20* Bottom view* Note: *Bottom is empty, the top of the enclosure appears 19” Mounting profile Front view 1005 780 780 F19 H H Front view Side view Back view 780 702 Front view 780 R08 72 300 H 300 927 1005 55 H= Enclosure height Top view Iso view Front view * F20 is the standard front door. 85
  • 87. EUROline free standing TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and Flame Resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP00.When bottom cover plate is used, it becomes IP20 IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 86 KEY FEATURES Main profile vertical (framework) has a structure which increases mechanical resistance with aesthetic appearance and a specially closed profile system of 30x30 mm from automation industry. Folded with an angle of 90 degree:The corner joints are welded with 4 fold connection brackets.The main profile vertical (framework) connects to top and bottom case with heavy duty 5 fold bended profile system. A total of 20 folds provide stability for the top and bottom case. Additionally, at 600x1000 and 800x1000 mm sizes a 5 fold (bend surface) bracket system provides additional stability, providing a 25 fold (bent surface) design criteria for the frame. Manufactured and tested to provide axial (x, y, z) resistance that meets EN 61587-1 / 5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Using a folded profile system for structure, the bottom and upper case are connected to the vertical profile system using heavy duty screws which provide modularity. Bottom case if fully open for large cable bundles to be placed; if required to close the bottom, a cover plate can be purchased as an optional accessory with sliding type edged cable entry panel. The rubber edge on the cable access plate and sliding structure, allows cables to be placed into the cabinet and fixed inside with no damage. For W=600 mm enclosure rear door is single solid metal, removable and lockable. Integral locking is single point barrel type locking system. For W=800 mm enclosure rear door in double opening, complete metal and 3 point handled locking. For options please see the related diagrams and technical charts On pages 71-77-81. Rear doors can be opened up to 220 degrees. Side panels have a structure that can be opened and removed with a key and are lockable and removable. Side panels are consist of 2 piece side panels on each side for D=1000 mm range due to easy handling and maintanence needs. Original functional side panel is lockable and removable as mentioned above; the smaller side panel is fixed from inner side with screws.Within this engineering construction the original functional side panel becomes easy to carry while installation and maintanance is in process. Front doors are single opening, left and right metal framed glass door, single point handled locking on the W=600 mm series, front doors are double opening, left and right metal framed glass door, 3 point handled locking on the W=800 mm series, front door can be opened up to 220 degrees, removable and lockable with handle type locking unit. For options please see the related diagrams and technical charts on pages 71-77-81. Vented top panel housing with a dedicated space for ventilation, fan module system allows easy installation of max. 4 fans from top. 19”(inch) mounting angles (2 ea. in front and 2 ea. in rear) are part of cabinets interior configuration and adjustable in depth. Baying is possible for side by side applications. Levelling feet are standard in shipping configuration.The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for environment with ISO 14001:2004 Environmental Management System.