SlideShare ist ein Scribd-Unternehmen logo
1 von 16
Fourier analysis                                                     Resonating LCR circuit with damping effect Cathode ray oscilloscope and related experiments. Trisha Banerjee @ 2010
Inside construction Numbers in the picture indicate: 1. Deflection voltage electrode; 2. Electron gun; 3. Electron beam; 4. Focusing coil; 5. Phosphor-coated inner side of the screen Trisha Banerjee @ 2010
Trisha Banerjee @ 2010
Time base control Intensity control Focus control Trisha Banerjee @ 2010
Examples of use Trisha Banerjee @ 2010
Moving  the initial line up and down Trisha Banerjee @ 2010
Pictures of use Heterodyne AC hum on sound Sum of a low-frequency and a high-frequency signal. Dual trace, showing different time bases on each trace Bad filter on sine. Trisha Banerjee @ 2010
Oscilloscopes are commonly used when it is desired to observe the exact wave shape of an electrical signal. In addition to the amplitude of the signal, an oscilloscope can show distortion and measure frequency, time between two events (such as pulse width or pulse rise time), and relative timing of two related signals. Some modern digital oscilloscopes can analyze and display the spectrum of a repetitive event. Special-purpose oscilloscopes, called spectrum analyzers, have sensitive inputs and can display spectra well into the GHz range. A few oscilloscopes that accept plug-ins can display spectra in the audio range. Focus control This control adjusts CRT focus to obtain the sharpest, most-detailed trace. In practice, focus needs to be adjusted slightly when observing quite-different signals, which means that it needs to be an external control. Flat-panel displays do not need a focus control; their sharpness is always optimum Intensity control This adjusts trace brightness. Slow traces on CRT 'scopes need less, and fast ones, especially if they don't repeat very often, require more. On flat panels, however, trace brightness is essentially independent of sweep speed, because the internal signal processing effectively synthesizes the display from the digitized data. Trisha Banerjee @ 2010
Timebase Controls These select the horizontal speed of the CRT's spot as it creates the trace; this process is commonly referred to as the sweep. In all but the least-costly modern 'scopes, the sweep speed is selectable and calibrated in units of time per major graticule division. Quite a wide range of sweep speeds is generally provided, from seconds to as fast as picoseconds (in the fastest 'scopes) per division. Usually, a continuously-variable control (often a knob in front of the calibrated selector knob) offers uncalibrated speeds, typically slower than calibrated. This control provides a range somewhat greater than that of consecutive calibrated steps, making any speed available between the extremes. Horizontal position control The horizontal position control moves the display sidewise. It usually sets the left end of the trace at the left edge of the graticule, but it can displace the whole trace when desired. This control also moves the X-Y mode traces sidewise in some 'scopes, and can compensate for a limited DC component as for vertical position. Trisha Banerjee @ 2010
Object :-              a) Finding the Fourier harmonics by using the Fourier  analysis. Apparatus:-  ac generator ,  CRO,   Fourier kit.             b)  To study the series and parallel LCR circuit and plot the resonance curve                   at constant frequency and capacity.                 Apparatus:  LCR kit , inductance coil.  Trisha Banerjee @ 2010
a) Ac frequency generator Fourier wave form type kit Fourier analysis experiment  whole setup CRO Trisha Banerjee @ 2010
b) Resonating circuit kit Air core inductance (for studying  the resonating in LCR and its damping effect) Trisha Banerjee @ 2010
Some of the brief features and experiment data of LCR resonant circuit 1) Circuit diagram for series LCR :- Trisha Banerjee @ 2010
Graph representation Series LCR having max current at cont capacity 700pF Series LCR having max current at cont frequency at 50 Hz Trisha Banerjee @ 2010
2) Circuit diagram for parallel LCR:- Trisha Banerjee @ 2010
Graph representation Parallel LCR having max current at cont capacity 700pF Parallel LCR having max current at cont frequency at 50 Hz Trisha Banerjee @ 2010

Weitere ähnliche Inhalte

Was ist angesagt?

Was ist angesagt? (20)

Cathode ray
Cathode rayCathode ray
Cathode ray
 
Cro(nnm)
Cro(nnm)Cro(nnm)
Cro(nnm)
 
CRO and functional generator physics
CRO and functional generator physicsCRO and functional generator physics
CRO and functional generator physics
 
Cro (emmi) (3)
Cro (emmi) (3)Cro (emmi) (3)
Cro (emmi) (3)
 
(19) electronic instruments 1
(19) electronic instruments 1(19) electronic instruments 1
(19) electronic instruments 1
 
Cro (cathod ray oscilloscope)
Cro (cathod ray oscilloscope)Cro (cathod ray oscilloscope)
Cro (cathod ray oscilloscope)
 
Cathode Ray Oscilloscope CRO & Digital Oscilloscope 'S WORKING
Cathode Ray Oscilloscope CRO & Digital Oscilloscope 'S WORKINGCathode Ray Oscilloscope CRO & Digital Oscilloscope 'S WORKING
Cathode Ray Oscilloscope CRO & Digital Oscilloscope 'S WORKING
 
Cathode Ray Oscilloscope
Cathode Ray OscilloscopeCathode Ray Oscilloscope
Cathode Ray Oscilloscope
 
Oscilloscopes and their Calibration-Web
Oscilloscopes and their Calibration-WebOscilloscopes and their Calibration-Web
Oscilloscopes and their Calibration-Web
 
Introduction to Oscilloscopes
Introduction to OscilloscopesIntroduction to Oscilloscopes
Introduction to Oscilloscopes
 
Understanding Lab Instruments
Understanding Lab InstrumentsUnderstanding Lab Instruments
Understanding Lab Instruments
 
Oscilloscope tutorial
Oscilloscope tutorialOscilloscope tutorial
Oscilloscope tutorial
 
Presentation on cro
Presentation on croPresentation on cro
Presentation on cro
 
cathode ray oscilloscope
cathode ray oscilloscopecathode ray oscilloscope
cathode ray oscilloscope
 
Cathode ray oscilloscope
Cathode ray oscilloscopeCathode ray oscilloscope
Cathode ray oscilloscope
 
Cro basics
Cro  basicsCro  basics
Cro basics
 
Oscilloscope
OscilloscopeOscilloscope
Oscilloscope
 
Cathode Ray Oscilloscope (CRO)
Cathode Ray Oscilloscope (CRO)Cathode Ray Oscilloscope (CRO)
Cathode Ray Oscilloscope (CRO)
 
Oscilloscopes basics
Oscilloscopes basicsOscilloscopes basics
Oscilloscopes basics
 
Emi unit ii ppt
Emi unit ii pptEmi unit ii ppt
Emi unit ii ppt
 

Andere mochten auch

Cathode ray-oscilloscope-cro-20 m-hz
Cathode ray-oscilloscope-cro-20 m-hzCathode ray-oscilloscope-cro-20 m-hz
Cathode ray-oscilloscope-cro-20 m-hzguest1471817
 
Experiment if planck's constant
Experiment if planck's constantExperiment if planck's constant
Experiment if planck's constantTrisha Banerjee
 
3 wave representations
3 wave representations3 wave representations
3 wave representationsMissingWaldo
 
Planck's constant presentation
Planck's constant presentationPlanck's constant presentation
Planck's constant presentationMechEProdigy
 
Two types of_waves
Two types of_wavesTwo types of_waves
Two types of_waveskoniasunset
 
Photoelectric effect ppt
Photoelectric effect pptPhotoelectric effect ppt
Photoelectric effect pptJason Baughman
 
Photoelectric effect ppt
Photoelectric effect pptPhotoelectric effect ppt
Photoelectric effect pptSantosh Jadhav
 

Andere mochten auch (8)

Cathode ray-oscilloscope-cro-20 m-hz
Cathode ray-oscilloscope-cro-20 m-hzCathode ray-oscilloscope-cro-20 m-hz
Cathode ray-oscilloscope-cro-20 m-hz
 
Experiment if planck's constant
Experiment if planck's constantExperiment if planck's constant
Experiment if planck's constant
 
3 wave representations
3 wave representations3 wave representations
3 wave representations
 
Mechanical properties
Mechanical propertiesMechanical properties
Mechanical properties
 
Planck's constant presentation
Planck's constant presentationPlanck's constant presentation
Planck's constant presentation
 
Two types of_waves
Two types of_wavesTwo types of_waves
Two types of_waves
 
Photoelectric effect ppt
Photoelectric effect pptPhotoelectric effect ppt
Photoelectric effect ppt
 
Photoelectric effect ppt
Photoelectric effect pptPhotoelectric effect ppt
Photoelectric effect ppt
 

Ähnlich wie Cathode ray oscilloscope and related experiments

1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...AL- AMIN
 
ADC Lab Analysis
ADC Lab AnalysisADC Lab Analysis
ADC Lab AnalysisKara Bell
 
Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...
Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...
Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...IRJET Journal
 
Cro cathode ray oscilloscope working and applications
Cro cathode ray oscilloscope working and applicationsCro cathode ray oscilloscope working and applications
Cro cathode ray oscilloscope working and applicationsEdgefxkits & Solutions
 
Design of Microcontroller Based Multi-Frequency Ultrasonic Pulser Receiver
Design of Microcontroller Based Multi-Frequency Ultrasonic Pulser ReceiverDesign of Microcontroller Based Multi-Frequency Ultrasonic Pulser Receiver
Design of Microcontroller Based Multi-Frequency Ultrasonic Pulser ReceiverIJERA Editor
 
Research Report-Kaidi Du-EECE4993
Research Report-Kaidi Du-EECE4993Research Report-Kaidi Du-EECE4993
Research Report-Kaidi Du-EECE4993Kaidi Du
 
A 20 gbs injection locked clock and data recovery circuit
A 20 gbs injection locked clock and data recovery circuitA 20 gbs injection locked clock and data recovery circuit
A 20 gbs injection locked clock and data recovery circuitVLSICS Design
 
Synchronization of Photo-voltaic system with a Grid
Synchronization of Photo-voltaic system with a GridSynchronization of Photo-voltaic system with a Grid
Synchronization of Photo-voltaic system with a GridIOSR Journals
 
Design and implementation of pll frequency synthesizer using pe3336 ic for ir...
Design and implementation of pll frequency synthesizer using pe3336 ic for ir...Design and implementation of pll frequency synthesizer using pe3336 ic for ir...
Design and implementation of pll frequency synthesizer using pe3336 ic for ir...elelijjournal
 
AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...
AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...
AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...VLSICS Design
 
Digital Implementation of Costas Loop with Carrier Recovery
Digital Implementation of Costas Loop with Carrier RecoveryDigital Implementation of Costas Loop with Carrier Recovery
Digital Implementation of Costas Loop with Carrier RecoveryIJERD Editor
 
An ECG-on-Chip for Wearable Cardiac Monitoring Devices
An ECG-on-Chip for Wearable Cardiac Monitoring Devices An ECG-on-Chip for Wearable Cardiac Monitoring Devices
An ECG-on-Chip for Wearable Cardiac Monitoring Devices ecgpapers
 

Ähnlich wie Cathode ray oscilloscope and related experiments (20)

Sub157
Sub157Sub157
Sub157
 
Ei unit 2
Ei unit 2Ei unit 2
Ei unit 2
 
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
 
En34855860
En34855860En34855860
En34855860
 
ADC Lab Analysis
ADC Lab AnalysisADC Lab Analysis
ADC Lab Analysis
 
Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...
Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...
Comparative Analysis of Natural Frequency of Transverse Vibration of a Cantil...
 
Cro cathode ray oscilloscope working and applications
Cro cathode ray oscilloscope working and applicationsCro cathode ray oscilloscope working and applications
Cro cathode ray oscilloscope working and applications
 
Design of Microcontroller Based Multi-Frequency Ultrasonic Pulser Receiver
Design of Microcontroller Based Multi-Frequency Ultrasonic Pulser ReceiverDesign of Microcontroller Based Multi-Frequency Ultrasonic Pulser Receiver
Design of Microcontroller Based Multi-Frequency Ultrasonic Pulser Receiver
 
Research Report-Kaidi Du-EECE4993
Research Report-Kaidi Du-EECE4993Research Report-Kaidi Du-EECE4993
Research Report-Kaidi Du-EECE4993
 
EMT PPT.....final.pptx
EMT PPT.....final.pptxEMT PPT.....final.pptx
EMT PPT.....final.pptx
 
A 20 gbs injection locked clock and data recovery circuit
A 20 gbs injection locked clock and data recovery circuitA 20 gbs injection locked clock and data recovery circuit
A 20 gbs injection locked clock and data recovery circuit
 
Types of cro
Types of croTypes of cro
Types of cro
 
Synchronization of Photo-voltaic system with a Grid
Synchronization of Photo-voltaic system with a GridSynchronization of Photo-voltaic system with a Grid
Synchronization of Photo-voltaic system with a Grid
 
Design and implementation of pll frequency synthesizer using pe3336 ic for ir...
Design and implementation of pll frequency synthesizer using pe3336 ic for ir...Design and implementation of pll frequency synthesizer using pe3336 ic for ir...
Design and implementation of pll frequency synthesizer using pe3336 ic for ir...
 
Unit 4 ei
Unit 4 eiUnit 4 ei
Unit 4 ei
 
AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...
AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...
AREA OPTIMIZED FPGA IMPLEMENTATION FOR GENERATION OF RADAR PULSE COM-PRESSION...
 
Digital Implementation of Costas Loop with Carrier Recovery
Digital Implementation of Costas Loop with Carrier RecoveryDigital Implementation of Costas Loop with Carrier Recovery
Digital Implementation of Costas Loop with Carrier Recovery
 
Frequency counter
Frequency counterFrequency counter
Frequency counter
 
An ECG-on-Chip for Wearable Cardiac Monitoring Devices
An ECG-on-Chip for Wearable Cardiac Monitoring Devices An ECG-on-Chip for Wearable Cardiac Monitoring Devices
An ECG-on-Chip for Wearable Cardiac Monitoring Devices
 
Ecg
EcgEcg
Ecg
 

Mehr von Trisha Banerjee

Mehr von Trisha Banerjee (11)

Stefan's constant
Stefan's constantStefan's constant
Stefan's constant
 
Experiment of finding the resolving power of the
Experiment of finding the resolving power of theExperiment of finding the resolving power of the
Experiment of finding the resolving power of the
 
Prism angle and minimum deviation
Prism angle and minimum deviationPrism angle and minimum deviation
Prism angle and minimum deviation
 
Platinum expt
Platinum exptPlatinum expt
Platinum expt
 
Nodal poinf with focal length
Nodal poinf  with focal lengthNodal poinf  with focal length
Nodal poinf with focal length
 
Lees disc
Lees discLees disc
Lees disc
 
Helmholtz galvanometer
Helmholtz galvanometerHelmholtz galvanometer
Helmholtz galvanometer
 
Fresnel & diffraction
Fresnel & diffractionFresnel & diffraction
Fresnel & diffraction
 
Ballistic galvanometer
Ballistic galvanometerBallistic galvanometer
Ballistic galvanometer
 
Common Detailed Writng
Common  Detailed WritngCommon  Detailed Writng
Common Detailed Writng
 
Oil Bath Exp
Oil Bath ExpOil Bath Exp
Oil Bath Exp
 

Cathode ray oscilloscope and related experiments

  • 1. Fourier analysis Resonating LCR circuit with damping effect Cathode ray oscilloscope and related experiments. Trisha Banerjee @ 2010
  • 2. Inside construction Numbers in the picture indicate: 1. Deflection voltage electrode; 2. Electron gun; 3. Electron beam; 4. Focusing coil; 5. Phosphor-coated inner side of the screen Trisha Banerjee @ 2010
  • 4. Time base control Intensity control Focus control Trisha Banerjee @ 2010
  • 5. Examples of use Trisha Banerjee @ 2010
  • 6. Moving the initial line up and down Trisha Banerjee @ 2010
  • 7. Pictures of use Heterodyne AC hum on sound Sum of a low-frequency and a high-frequency signal. Dual trace, showing different time bases on each trace Bad filter on sine. Trisha Banerjee @ 2010
  • 8. Oscilloscopes are commonly used when it is desired to observe the exact wave shape of an electrical signal. In addition to the amplitude of the signal, an oscilloscope can show distortion and measure frequency, time between two events (such as pulse width or pulse rise time), and relative timing of two related signals. Some modern digital oscilloscopes can analyze and display the spectrum of a repetitive event. Special-purpose oscilloscopes, called spectrum analyzers, have sensitive inputs and can display spectra well into the GHz range. A few oscilloscopes that accept plug-ins can display spectra in the audio range. Focus control This control adjusts CRT focus to obtain the sharpest, most-detailed trace. In practice, focus needs to be adjusted slightly when observing quite-different signals, which means that it needs to be an external control. Flat-panel displays do not need a focus control; their sharpness is always optimum Intensity control This adjusts trace brightness. Slow traces on CRT 'scopes need less, and fast ones, especially if they don't repeat very often, require more. On flat panels, however, trace brightness is essentially independent of sweep speed, because the internal signal processing effectively synthesizes the display from the digitized data. Trisha Banerjee @ 2010
  • 9. Timebase Controls These select the horizontal speed of the CRT's spot as it creates the trace; this process is commonly referred to as the sweep. In all but the least-costly modern 'scopes, the sweep speed is selectable and calibrated in units of time per major graticule division. Quite a wide range of sweep speeds is generally provided, from seconds to as fast as picoseconds (in the fastest 'scopes) per division. Usually, a continuously-variable control (often a knob in front of the calibrated selector knob) offers uncalibrated speeds, typically slower than calibrated. This control provides a range somewhat greater than that of consecutive calibrated steps, making any speed available between the extremes. Horizontal position control The horizontal position control moves the display sidewise. It usually sets the left end of the trace at the left edge of the graticule, but it can displace the whole trace when desired. This control also moves the X-Y mode traces sidewise in some 'scopes, and can compensate for a limited DC component as for vertical position. Trisha Banerjee @ 2010
  • 10. Object :- a) Finding the Fourier harmonics by using the Fourier analysis. Apparatus:- ac generator , CRO, Fourier kit. b) To study the series and parallel LCR circuit and plot the resonance curve at constant frequency and capacity. Apparatus: LCR kit , inductance coil. Trisha Banerjee @ 2010
  • 11. a) Ac frequency generator Fourier wave form type kit Fourier analysis experiment whole setup CRO Trisha Banerjee @ 2010
  • 12. b) Resonating circuit kit Air core inductance (for studying the resonating in LCR and its damping effect) Trisha Banerjee @ 2010
  • 13. Some of the brief features and experiment data of LCR resonant circuit 1) Circuit diagram for series LCR :- Trisha Banerjee @ 2010
  • 14. Graph representation Series LCR having max current at cont capacity 700pF Series LCR having max current at cont frequency at 50 Hz Trisha Banerjee @ 2010
  • 15. 2) Circuit diagram for parallel LCR:- Trisha Banerjee @ 2010
  • 16. Graph representation Parallel LCR having max current at cont capacity 700pF Parallel LCR having max current at cont frequency at 50 Hz Trisha Banerjee @ 2010